ItemModel No.TSM300012 Basic typeTSM3000H12 Economy typeTSM3000H2Load slavedtracking typeTSM3000M1Contactdetection typeTSM3000M2Integral power typeTSM3000C1Built-in forward/reversesequencer typeAppliedmotorCapacity3 Power source voltageFrequency0.1 110kWAC200/220V, AC400/440V5 120HzControl power supply voltageAC90 250 V50/60Hz, DC90 250V Nonpolar3 Motor voltageAC250V, MAXInputCurrent sensorDC2.5VControl inputX1, X2, X3, IHX1, X2, RESX1, RESX1, X2, X3, X4, X5X1, X2, X3, X4, X5X1, X2No. of contact3c2c2c2a, 1c2a, 1c3a, 1bOutputOutputrelay lifeMechanicalElectrical10,000,000 activations100,000 activationsAnalog output relay DC2V1.5VDC0 3.0VLoadsettinglevelOutput 1Output 2Output 3High1 200 200High2 200 200Low 99 99HIGH1 5 200HIGH2 5 200HIGH1 1 99HIGH2 5 200OUT1 1 99OUT2 1 99OUT3 5 200OUT1 0 99OUT2 5 200OUT3 5 200<strong>Overload</strong> 5 200No load 5 200Start time setting rangeShock time0.1 20.0s“MIN” or 0.1 10.0s1 300ssetting rangeIn case motor power souce frequency is 50Hz and higher, shock time at “MIN” is approximately 30ms.ReponseSet by number ofmoving averageQUICK (Average no. 1 time), NORMAL (Average no. 5 times), SLOW (Average no. 20 times)4 Inhibit functionRelay self-holdingManual/auto switchingAutoinhibitSelf-hold/auto reset selectableManual/auto switchingOnly OUT3 is selectableAutoinhibitSequencer functionSwitching detection level 8 steps4 stepsNone8 stepsNoneTest functionPeak-holdfunctionRelay output testWhen the load ratio exceeds the pre-set level (or falls below it), shows the maximum value within shock time.Only when the output is set as self-hold, it is peak hold.% Power display range 200 2000 200Voltage display rangeCurrent display rangeFrequency display range0 500V0.01 999A5 120HzPower consumptionApproximate mass10VA (Inrush current 5A within 5ms)1.0kgAmbienttemperature0 50WorkReative humidity45 85% RH; there is no condensationenvironment Altitude1000m and lessAmbientatomosphereNo corrosive gas, dust SettingFunctionDisplayRelay contactoutputAC250V, 0.5A (Inductive load cos 0.4)DC30V, 0.4A (Inductive load) DC110V, 0.2A (Inductive load) Minimum load applicable DC24V, 4mA 131 132

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!