was designed to deliver a dose of 140 millijoules per square centimeter to meet all disinfection<br />

goals <strong>for</strong> Giardia, Cryptosporidium, and viruses at a design UV transmittance of 60 percent.<br />

The cost of a 5-MGD bank filtration/ozonation/UV-disinfection treatment facility is approximately<br />

$4,759,000 <strong>for</strong> design and construction and $147,000 per year <strong>for</strong> O&M (or $0.20 per 1,000 gallons<br />

of water produced). This translates into a normalized capital cost of $0.95 per gallons per day of<br />

capacity and a production cost of $0.70.<br />

BOB CUSHING has 14 years of experience in applied environmental science and<br />

engineering. Throughout his career, he has coupled fundamental concepts with sound<br />

engineering practices to provide creative, innovative, and enduring solutions to challenges<br />

faced by water and wastewater utilities. Cushing has been responsible <strong>for</strong> numerous<br />

successful treatment facility planning and design projects, as well as studies and programs<br />

<strong>for</strong> improving distribution system water quality. Cushing has practiced nationally,<br />

providing service to a broad cross-section of the industry, from some of the largest and most<br />

visible utilities (e.g., New York City and Washington, D.C.) to very small applications with important and<br />

unique issues (e.g., Oray <strong>National</strong> Fish Hatchery, Utah). He has also been responsible <strong>for</strong> introducing and<br />

applying advanced technologies, most notably ultraviolet disinfection <strong>for</strong> potable water treatment. An<br />

internationally recognized expert in ultraviolet disinfection, he is responsible <strong>for</strong> seminal applied research in<br />

this area, and is project manager and a primary author <strong>for</strong> the United States Environmental Protection<br />

Agency’s Ultraviolet Disinfection Guidance Manual. Cushing received a B.S. in Petroleum Engineering and an<br />

M.S. and Ph.D. in Civil Engineering from the University of Texas at Austin.<br />