11.07.2015 Views

Water Chiller VWK/1 Hyfra - Industrial Technologies

Water Chiller VWK/1 Hyfra - Industrial Technologies

Water Chiller VWK/1 Hyfra - Industrial Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Индастриал Технолоджис www.ind-techno.com.ua +38 044 596 04 29<strong>Industrial</strong> <strong>Technologies</strong><strong>VWK</strong> water chillerStandard equipment: <strong>Water</strong> control Stainless steel frame Stainless steel coil evaporator <strong>Chiller</strong> IP 54 Operating temp. 37° C max. ambient High tech scoll compressor / low noise High efficiency air cooled condensator Digital thermostat hysteresis +/- 1,0 K Refrigerant circuit with TÜV approved low and highpressure switch By-Pass valve Draining through water level control All systems with control transformer.no neutral required Environment friendly refridgerant R407C CH-pump with carbide / carbide shaft seal Panels in RAL colour on requestOptions: DC voltage - control circuit Drain valve for tank <strong>Water</strong> outlet manometer <strong>Water</strong> level switch for pump-protection Winter start up regulation (0-50-100%) Common alarm (potential free) Special voltage Flow switch Common alarm (potential free) <strong>Water</strong> set point +40° C max. Hand shut off valve betweentank and pump Wire labelling Harting connectors / plugs Refrigerant R 134 A Non return valve + magnetic valve Hysteresis +/- 0,3 K Air filter Stop process with low/high temperature alarm CR-pump for pressure above 3 bar withcarbide / carbide shaft seal Stainless steel piping Operating temperature > 37° C ambientBasket evaporatorTemperatures<strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong>20/1 30/1 50/1 70/1 90/1 110/1 140/1 180/1 220/1 270/1 320/1 360/1 440/1 540/1 640/1Ambient air <strong>Water</strong> Cooling capacities in kW10° C 1,9 3,2 5,2 6,6 9,7 11,8 14,1 16,9 21,4 25,7 31,4 33,9 42,9 51,4 62,932° C 15° C 2,4 4,0 6,2 7,8 11,5 13,9 16,6 20,0 25,3 29,9 37,0 40,0 50,7 59,9 74,120° C 2,7 4,5 6,9 8,7 12,6 15,4 18,3 21,7 28,0 33,5 41,5 43,5 56,0 67,1 83,110° C 1,8 2,8 5,1 6,0 9,1 10,9 13,1 16,7 20,2 23,9 29,6 33,4 40,5 47,9 59,237° C 15° C 2,5 3,6 6,1 7,2 10,7 13,0 15,7 20,0 23,9 28,2 34,9 40,0 47,8 56,5 69,820° C 2,6 4,1 6,7 7,9 11,8 14,4 17,2 21,7 25,6 31,1 37,9 43,5 51,3 62,4 75,910° C 1,7 3,2 4,7 5,9 8,7 9,1 12,9 15,6 19,6 22,9 25,0 31,4 39,3 45,8 50,042°C 15° C 2,1 3,4 5,7 7,1 10,2 11,4 15,4 18,5 23,5 27,4 30,9 37,0 47,1 54,9 61,920° C 2,6 3,9 6,4 7,9 11,2 13,0 17,0 20,4 25,6 30,2 35,0 40,9 51,3 60,6 70,0All standard machines are specified for a maximum ambient temperature of + 37° C.*) Machines for + 42° C maximum ambient temperature are available at extra cost. Machine sizes will not change.Competence and Experience in <strong>Industrial</strong> Cooling SystemsTechnical dateCooling capacitiesSpecifications<strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong> <strong>VWK</strong>20/1 30/1 50/1 70/1 90/1 110/1 140/1 180/1 220/1 270/1 320/1 360/1 440/1 540/1 640/1Number of Scrollcompressors1 1 1 1 1 1 1 1 1 1 1 2 2 2 2Power consumptioncompressor max. kW 1,4 2,0 2,6 3,1 4,3 5,9 6,2 7,9 9,7 11,1 15,5 15,8 19,4 22,2 31,0Power consumptionmax. kW 2,6 3,4 4,0 4,7 6,1 7,9 8,9 10,6 12,4 14,2 18,9 21,2 24,8 28,4 37,2Currentmax. A 4,8 6,2 7,1 8,1 10,6 13,9 15,4 18,7 21,3 25,0 32,2 37,7 42,9 50,3 63,1Air flow rate max. m 3 /h 2800 4500 4500 4500 5500 6100 9300 9300 9300 11000 12600 18600 18600 22000 25200<strong>Water</strong> tank volume ltr. 90 90 90 120 120 120 300 300 300 300 300 500 500 500 500<strong>Water</strong> pressure bar 3,4 3,4 3,4 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 4,0 4,0 4,0 4,0Nominal water flow m 3 /h 1,5 1,5 1,5 2,0 2,0 2,0 3,5 3,5 3,5 3,5 3,5 8,0 8,0 8,0 8,0<strong>Water</strong> connectioninlet / outlet inch 3/4 374 3/4 3/4 3/4 3/4 1 1 1 1 1 2 2 2 2<strong>Water</strong> connectionsfeed inch 3/4 374 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4Length (L) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 2000 2000 2000 2000Width (B) mm 715 715 715 715 715 715 1000 1000 1000 1000 1000 1000 1000 1000 1000Height (H) mm 1375 1375 1375 1375 1375 1375 2000 2000 2000 2000 2000 2000 2000 2000 2000Weight (approx.) kg 170 170 180 190 200 200 320 370 400 400 410 740 800 800 810Power supply 3/PE/400 V/50 Hz. Control voltage 24 V AC. All technical data is valid for machines with a maximum ambient temperature of + 42° C.Specifications subject to change.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!