66 <strong>Sit</strong>e PreparationEnvironmental RequirementsBarometric PressureThe <strong>7401</strong> is designed to operate within the following barometricpressure conditions:• Maximum operating altitude: 3000 m (9843 ft)• Operating range of pressure: 105 kPa to 69 kPa (15.2 lb./in. to10.0 lb./in.)TemperatureThe <strong>7401</strong> is designed to operate over the temperature ranges shownbelow. Continuous operation must be avoided, however, at or near thetemperature extremes, or in locations where temperature changesexceed the temperature restrictions.Temperature Parameter RestrictionOperating 5 o C to 45 o C (41 o F to 113 o F), dry bulbStorage -10 o C to 50 o C (14 o F to 122 o F), three monthsShipping -40 o C to 60 o C (-40 o F to 140 o F), one weekDew Point 26 o C (79 o F) maximumHumidityThe <strong>7401</strong> is designed to operate within the humidity ranges shownbelow. Continuous operation must be avoided, however, at or near thehumidity limits, or in locations where humidity changes exceed thehumidity restrictions.Humidity TypeRestrictionRelative 10% to 90%Maximum change rate 10%/60 minutesStorage10% to 90% relative humidity, three monthsShipping5% to 95% relative humidity, one week