This instruction is True's<br />
recommended procedure for<br />
installing a remote CO 2 container.<br />
REQUIRED TOOLS<br />
• Pliers<br />
• Power Drill<br />
• Silicone sealer<br />
• Drill bit, 1/2”<br />
INSTALLATION INSTRUCTION<br />
TDD-2,3,4 (and Club Top models) CO 2 Knock-out<br />
__________ STEP 1 __________<br />
Remove black knockout plug with<br />
a pair of pliers.<br />
__________ STEP 2 __________<br />
Use drill to bore hole through insulation<br />
while holding tool at a 30°<br />
angle, this should line up with a<br />
pre-punched hole in the compressor<br />
compartment.<br />
91<br />
__________ STEP 3 __________<br />
Snake CO 2 line through knockout<br />
hole and newly drilled hole and<br />
route through rear grill louvers.<br />
__________ STEP 4 __________<br />
Seal hole around CO 2 line with silicone<br />
sealer to prevent cold air<br />
leakage.