This instruction is True's<br />

recommended procedure for<br />

installing a remote CO 2 container.<br />

REQUIRED TOOLS<br />

• Pliers<br />

• Power Drill<br />

• Silicone sealer<br />

• Drill bit, 1/2”<br />

INSTALLATION INSTRUCTION<br />

TDD-2,3,4 (and Club Top models) CO 2 Knock-out<br />

__________ STEP 1 __________<br />

Remove black knockout plug with<br />

a pair of pliers.<br />

__________ STEP 2 __________<br />

Use drill to bore hole through insulation<br />

while holding tool at a 30°<br />

angle, this should line up with a<br />

pre-punched hole in the compressor<br />

compartment.<br />

91<br />

__________ STEP 3 __________<br />

Snake CO 2 line through knockout<br />

hole and newly drilled hole and<br />

route through rear grill louvers.<br />

__________ STEP 4 __________<br />

Seal hole around CO 2 line with silicone<br />

sealer to prevent cold air<br />

leakage.