INSTALLATION INSTRUCTION<br />
TEMPERATURE CONTROL REPLACEMENT CONTINUED.......<br />
___________ STEP 6 ___________<br />
Replace existing temperature control<br />
with new Danfoss control in repair kit:<br />
(See Figure 8).<br />
A. Connect one pink wire from old<br />
control to double terminal #4 on<br />
new temperature control.<br />
B. Place the plastic-coated spade<br />
clip on secondary #4 terminal.<br />
C. Connect other pink wire from old<br />
control to terminal #3 on new<br />
Danfoss temperature control.<br />
(See Figure 8 & 9).<br />
___________ STEP 7 ___________<br />
Anchor the Relay Shield:<br />
(See Figure 10).<br />
A. Secure the new relay by<br />
attaching the relay shield.<br />
B. Relay shield includes two selftapping<br />
screws. When installing<br />
shield, place shield in position to<br />
cover relay and all exposed wiring.<br />
Figure 8. Temperature Control Leads<br />
46<br />
Figure 10. Anchoring Relay Shield