INSTALLATION INSTRUCTION<br />

TEMPERATURE CONTROL REPLACEMENT CONTINUED.......<br />

___________ STEP 4 ___________<br />

Relay Connection Mounting:<br />

A. With slotted screw driver and<br />

plastic mallet or hammer, drive out<br />

knock out positioned on left side of<br />

ballast box. (See Figure 3).<br />

B. Install the supplied grommet*<br />

into the knockout hole. (See Figure 4).<br />

C. Mount relay to underside of<br />

unit on the left side of ballast box,<br />

and 3/4” back from the front edge<br />

of the underside.<br />

NOTE: Mount relay next to the<br />

ballast box, so that when the relay<br />

shield is installed it covers the relay<br />

and all exposed wiring.<br />

Relay should be anchored with two<br />

self-tapping screws, (supplied in kit),<br />

as pictured in Figure 5.<br />

*Grommet<br />

Figure 3. Driving out knockout<br />

Figure 4. Installing the grommet<br />

44<br />

Figure 5. Anchoring relay