23.11.2012 Views

Technical Service Manual - mbm-Service GmbH

Technical Service Manual - mbm-Service GmbH

Technical Service Manual - mbm-Service GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Terms:<br />

INSTALLATION INSTRUCTION<br />

Danfoss Temperature Control Adjustment for High Altitude Applications<br />

Cut-out - Temperature sensed by the<br />

controller that shuts the compressor<br />

off.<br />

Cut-in - Temperature sensed by the<br />

controller that turns the compressor on.<br />

Instructions:<br />

___________ STEP 1 ___________<br />

Mechanical temperature controllers are<br />

affected when functioning at high altitude.<br />

The cut-in and cut-out temperatures<br />

will be colder than when the controller<br />

function closer to sea level.<br />

___________ STEP 2 ___________<br />

For installations above 2,000 ft., it may<br />

be necessary to “warm-up” the set<br />

points. To make the adjustment, insert<br />

the appropriate tool in each adjustment<br />

screw and turn 1/4 of a revolution<br />

clock-wise (to the right). This procedure<br />

will adjust both the cut-in and<br />

cut-out about 2˚F warmer.<br />

___________ STEP 3 ___________<br />

Make sure to re-connect the pink wires<br />

to the proper spade terminal when<br />

re-installing.<br />

Compressor Connection (pink)<br />

12<br />

Cut-out Adjustment Screw<br />

Allen (5/64” or 2 mm.)<br />

Cut-in Adjustment<br />

Screw Torx (T-7)<br />

Compressor Connection (pink)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!