11.07.2015 Views

Precision LCR Meter 7600 Plus Meter - HTDS

Precision LCR Meter 7600 Plus Meter - HTDS

Precision LCR Meter 7600 Plus Meter - HTDS

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Precision</strong> <strong>LCR</strong> <strong>Meter</strong><strong>7600</strong> <strong>Plus</strong> <strong>Meter</strong> Page 2 of 3SPECIFICATIONSMeasurement accuracyParameter Measurement RangeBasic AccuracyLow Medium HighLs, Lp 000.001 nH to 99.999 99 H ±0.5% ±0.25% ±0.05%Cs, Cp 00,000.01 fF to 9.999 999 F ±0.5% ±0.25% ±0.05%│Z│, Rs, Rp, ESR, Xs 000.000 1 Ω to 99.999 99 MΩ ±0.5% ±0.25% ±0.05%Q 0.000 001 to 999,999.9 ±0.005 ±0.0025 ±0.0005D 0.000 001 to 99,999 ±0.005 ±0.0025 ±0.0005Θ -180.000 0° to +179.999 9° ±1.8° ±0.9° ±0.18°│Y│, Gp, Bp 00,000.01 µS to 9.999 99 MS ±0.5% ±0.25% ±0.05%For more detailed accuracy information, see <strong>7600</strong>+ instruction manualAny two of the 14 parameters can be measured and displayed simultaneously (user-selectable)Measurement speedSpeedFast AccuracyMedium AccuracySlow AccuracyAccuracy Setting120 meas/sec16 meas/sec - 8 meas/sec below 150 kHz2 meas/sec - 1 meas/sec below 150 kHzThe speed may be slower depending on test conditions andfrequency settingsTest frequency range:10 Hz to 2 MHzTest frequency resolution10 Hz to ≤10 kHz: 0.1 Hz>10 kHz to ≤100 kHz: 5 digits>100 kHz: 4 digitsAccuracy: ±(0.01% + 0.10 Hz)RangingAutomatic, Range Hold, or user-selectableTriggerInternal (automatic)External (RS-232, IEEE-488.2, or HandlerInterfaces)ManualAC test signal voltage1 MHz: 20 mV to 0.5 V (open circuit) in 5mV stepsAC test signal current250 µA to 100 mA (short circuit) in 50 µAstepsMax Compliance 3 V < 500 kHz25 Ω, 400 Ω, 6.4 kΩ, or 100 kΩmeasurement range dependentDC bias voltageInternal: 2.0 VExternal: 0 to ±200 VDisplayLCD graphics with backlight and adjustablecontrastResults formatEngineering or scientific5 deviation from nominalDeviation from nominalPass/FailBinning summaryNo display (for maximum throughput)Sweep resultPrimary parameter vs. frequency, voltage, orcurrentGraphical or tabular formatUp to 200 measurement point per sweepAutoAccAutomatic calculation and display of overallinstrument accuracy for selected settings,test conditions, and device under testInterfacesStandard: USB host port, RS-232, Handler,Printer portOptional: IEEE-488.2Charged capacitor protectionVmax ≤250 V: √(8/C)Vmax ≤1000 V: √(2/C)C = capacitance in farads of device undertestMeasurement delayProgrammable from 0 - 1000 ms in 1 msstepsAveragingProgrammable from 1 - 1000Median value mode availableData storageUSB host port 1.1 complaint, CSV formatProgram storageInternal memoryUSB host portASCII formatCalibrationBuilt-in automatic calibration procedureIET offers complete, SI traceable calibrationusing the 7000-09 cal kitRecommended calibration interval: 1 yearUsage and calibration dataDisplays last calibration date, standardvalues used in calibration, and number ofhours of operationContact checkTime to detect, 2 msConnection terminalsFour bnc connectors located on the frontpanelMechanicalDimensions: 41 cm W x 15 cm H x 36 cm D(16" x 6" x 14")Weight: 8 kg (17 lbs)Environmental ConditionsOperating temperature: 0 to 50°C,


<strong>Precision</strong> <strong>LCR</strong> <strong>Meter</strong><strong>7600</strong> <strong>Plus</strong> <strong>Meter</strong> Page 3 of 3ORDERING INFORMATION<strong>7600</strong> <strong>Plus</strong> <strong>Meter</strong> Standard Set:<strong>Precision</strong> <strong>LCR</strong> <strong>Meter</strong>AC Power CordInstruction ManualCalibration Certificate traceable to SIFlash drive, 2 GBOPTIONAL ACCESSORIES:Remote Test Fixture 1689-9600Kelvin Test Leads 1700-03IEEE Interface Option 7000-22SMD Test Fixture 7000-07bnc-bnc Extender Cable, 1 m 1689-9602bnc-bnc Extender Cable, 2 m 1689-9602-2Chip Component Tweezers 7000-05Also available:Rack Mount Kit 7000-00RS232-to-USB Adapter 630250Alligator Clip Leads 7000-04Calibration Kit 7000-09IET LABS, INC. in the GenRad Tradition534 Main Street, Westbury, NY 11590www.ietlabs.comTEL: (516) 334-5959 • (800) 899-8438 • FAX: (516) 334-5988

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!