HFM-401/405 - Teledyne Hastings Instruments
HFM-401/405 - Teledyne Hastings Instruments HFM-401/405 - Teledyne Hastings Instruments
4.1. FittingsFittingsHastings#HFM-I-4011/2" Swagelok Fittings 41-03-0861/2" VCO Fittings 41-03-1191/2" VCR Fittings 41-03-0903/4" Swagelok Fitting 41-03-15210 mm Swagelok 41-03-1533/8" Male NPT 41-03-1541/2" Male NPT 41-03-15512 mm Swagelok 41-03-1603/4-16 SAE/MS Straight Female (no fitting) N/AHFM-I-4051" Swagelok fitting 41-03-1423/4" Swagelok 41-03-1491" VCO Fitting 41-03-1471" VCR fitting 41-03-1481" Male NPT 41-03-1503/4" Male NPT 41-03-1511 5/16-12 Female SAE/MS straight thread (no fitting) N/A4.2. CablesDescriptionHastingsStock#Remote Electronics Cables2 meter cable remote mounting cable CB-8P-M12-2MRA5 meter remote mounting cable CB-8P-M12-5MRA10 meter remote mounting cable CB-8P-M12-10MRA401 Local Bracket - mount direct to sensor 14-03-002405 Local Bracket - mount direct to sensor 14-03-001Digital Communications9 pin RS232 to 400 series M12 connector CB-RS232-M12Digital M12 connector to M12 connector CB-ETHERNET-M12USB to 9 pin RS232 connectorCB-USB-RS232RJ45 Ethernet to M12 Ethernet connector CB-RJ45-M12Analog I/O8 foot D connector to 8 bare leads CB-D15-Lead-825 foot D connector to 8 bare leads CB-D15-Lead-25100 foot D connector to 8 bare leads CB-D15-Lead-100401-405 SERIES - 22 -
5. WARRANTY5. Warranty5.1. Warranty Repair PolicyHastings Instruments warrants this product for a period of one year from the date of shipment to be freefrom defects in material and workmanship. This warranty does not apply to defects or failures resultingfrom unauthorized modification, misuse or mishandling of the product. This warranty does not apply tobatteries or other expendable parts, nor to damage caused by leaking batteries or any similar occurrence.This warranty does not apply to any instrument which has had a tamper seal removed or broken.This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty asto fitness for a particular use. Hastings Instruments shall not be liable for any indirect or consequentialdamages.Hastings Instruments, will, at its option, repair, replace or refund the selling price of the product ifHastings Instruments determines, in good faith, that it is defective in materials or workmanship duringthe warranty period. Defective instruments should be returned to Hastings Instruments, shipmentprepaid, together with a written statement of the problem and a Return Material Authorization (RMA)number.Please consult the factory for your RMA number before returning any product for repair. Collect freightwill not be accepted.5.2. Non-Warranty Repair PolicyAny product returned for a non-warranty repair must be accompanied by a purchase order, RMA formand a written description of the problem with the instrument. If the repair cost is higher, you will becontacted for authorization before we proceed with any repairs. If you then choose not to have theproduct repaired, a minimum will be charged to cover the processing and inspection. Please consult thefactory for your RMA number before returning any product repair.TELEDYNE HASTINGS INSTRUMENTS804 NEWCOMBE AVENUEHAMPTON, VIRGINIA 23669 U.S.A.ATTENTION: REPAIR DEPARTMENTTELEPHONE (757) 723-65311-800-950-2468FAX (757) 723-3925E MAILhastings_instruments@teledyne.comINTERNET ADDRESS http://www.hastings-inst.comRepair Forms may be obtained from the “Information Request” section of theHastings Instruments web site.401-405 SERIES - 23 -
- Page 4 and 5: 401-405 SERIES - iv -
- Page 6: CAUTIONThis instrument is available
- Page 9 and 10: 1. General Information1. General In
- Page 11 and 12: MechanicalFittings Standard: 1/2" S
- Page 13 and 14: 2.4. Mounting the Electronics Remot
- Page 15 and 16: the range of 5-28 Vdc from a source
- Page 17 and 18: 2.1.1.2. Voltage outputIf the flow
- Page 19 and 20: Since the alarms act as switches th
- Page 21 and 22: Example 2- Changing the active gas
- Page 23 and 24: 3. Operation3. OperationThe Hasting
- Page 25 and 26: 3.4.2. Adjusting ZeroThe pre-condit
- Page 27 and 28: 3.7.1. Zero ShiftThe zero offset ca
- Page 29: 4. Parts and Accessories4. Parts &
- Page 33 and 34: 6.2. Appendix 2 - Gas Conversion Fa
- Page 35 and 36: 37 Cyclopropane C 3 H 6 0.4562 4 1.
- Page 38 and 39: HFM-I-405Flow meter401-405 SERIES -
4.1. FittingsFittings<strong>Hastings</strong>#<strong>HFM</strong>-I-<strong>401</strong>1/2" Swagelok Fittings 41-03-0861/2" VCO Fittings 41-03-1191/2" VCR Fittings 41-03-0903/4" Swagelok Fitting 41-03-15210 mm Swagelok 41-03-1533/8" Male NPT 41-03-1541/2" Male NPT 41-03-15512 mm Swagelok 41-03-1603/4-16 SAE/MS Straight Female (no fitting) N/A<strong>HFM</strong>-I-<strong>405</strong>1" Swagelok fitting 41-03-1423/4" Swagelok 41-03-1491" VCO Fitting 41-03-1471" VCR fitting 41-03-1481" Male NPT 41-03-1503/4" Male NPT 41-03-1511 5/16-12 Female SAE/MS straight thread (no fitting) N/A4.2. CablesDescription<strong>Hastings</strong>Stock#Remote Electronics Cables2 meter cable remote mounting cable CB-8P-M12-2MRA5 meter remote mounting cable CB-8P-M12-5MRA10 meter remote mounting cable CB-8P-M12-10MRA<strong>401</strong> Local Bracket - mount direct to sensor 14-03-002<strong>405</strong> Local Bracket - mount direct to sensor 14-03-001Digital Communications9 pin RS232 to 400 series M12 connector CB-RS232-M12Digital M12 connector to M12 connector CB-ETHERNET-M12USB to 9 pin RS232 connectorCB-USB-RS232RJ45 Ethernet to M12 Ethernet connector CB-RJ45-M12Analog I/O8 foot D connector to 8 bare leads CB-D15-Lead-825 foot D connector to 8 bare leads CB-D15-Lead-25100 foot D connector to 8 bare leads CB-D15-Lead-100<strong>401</strong>-<strong>405</strong> SERIES - 22 -