11.07.2015 Views

Chapter 7 - Veterinary Instrumentation

Chapter 7 - Veterinary Instrumentation

Chapter 7 - Veterinary Instrumentation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.vetinst.comTRAUMA IMPLANTS & INSTRUMENTS 7ImplantsAll the 1.0mm Plates are manufactured from 316LVM stainless steelsheet of 1.0mm thickness. Implants currently available consist of a rangeof straight plates, cuttable plates and, given the target patient range, anextensive range of ‘T’ plates for radial fractures.1.0mm Cortical Self Tapping ScrewsAvailable 4mm to 15mm length. Use0.7mm pilot drill and 1.0mm cruciatescrewdriver. The threads on thescrews are very fine. Caution mustbe exercised at the final tightening.1.0mm CORTICAL SELF TAPPING SCREWS-CRUCIATE HEAD (use 0.7mm pilot)CSST1004 4mm £4.75CSST1005 5mm £4.75CSST1006 6mm £5.25CSST1007 7mm £5.25CSST1008 8mm £5.75CSST1009 9mm £5.75CSST1010 10mm £6.25CSST1011 11mm £6.25CSST1012 12mm £7.00CSST1013 13mm £7.00CSST1014 14mm £7.50CSST1015 15mm £7.501.0mm Compression Plates1.0 mm COMPRESSION PLATESUse with 1.0mm cortical screwsif compression is required.Plate profile page 391.no. of holes thickness (mm) length (mm)C100210 2 1.0 10 £27.50C100314 3 1.0 14 £30.00C100418 4 1.0 18 £35.00C100522 5 1.0 22 £42.50C100626 6 1.0 26 £47.50C100730 7 1.0 30 £60.00C100834 8 1.0 34 £75.00C100938 9 1.0 38 £85.00C101042 10 1.0 42 £95.00www.vetinst.com2.4 DCPsBone Plate ProfileAll our bone plate profiles are printedon the pages inside the back cover.They are also in the documentdownload section ofwww.vetinst.com A full set of profilesprinted on clear acetates as an aid tofracture planning is available free ofcharge.Remember the profiles are actualsize so you will have to compensate(5-10%) for magnification dependingon the position of the bone and thehead of the x-ray unit.Designed by Vets for Vets1.0mm Cuttable PlatesCUTTABLE 1.0MM PLATECP10390 Cuttable Plate 1.0mm 30 Holes 90 mm long £95.00CP10491 Cuttable Plate 1.0mm 23 Holes 91 mm long £95.00CM10390 Cuttable Malleable Plate 1.0mm 30 Holes 90 mm £115.00CUTTABLE 1.0MM PLATE WITH SPACESCP1039027 Cuttable Plate 1.0mm 27 Holes 90 mm 3mm Spaces £100.00CP1049120 Cuttable Plate 1.0mm 20 Holes 91 mm 4mm Spaces £100.00001230 Compound Action Implant Cutter T.C. Jaws £195.001.0 mm ‘T’ PLATES1.0mm Cuttable Malleable 3.0mm Spacing1.0mm Cuttable 3.0mm Spacing1.0mm Cuttable 3.0mm Spacing with spaces1.0mm Cuttable 4.0mm Spacing1.0mm Cuttable 4.0mm Spacing with spacesThe <strong>Veterinary</strong> <strong>Instrumentation</strong> range of Cuttable 1.0mm Plates givesflexibility for new management options for a number of different fracturescenarios. All of our Cuttable Plates have round holes.The range is suitedto fractures of the small bones of the pes and manus as well as other finebones such as the ulna and fibula. They should also find a home in themanagement of long bone fractures on very small animals as well as jawand pelvic repairs where space is at a premium. In 2012 we added a1.0mm Cuttable Plate with Spaces to give the surgeon additional options.Versions are available with either 3mm or 4mm hole spacing.Use the dedicated Compound Action Implant Cutters (001230) to sectionplates. Plate profile on page 391.1.0mm ‘T’ PlatesSeries ‘A’ 4.6mm between head and shaft holesSeries ‘B’ 6.6mm between head and shaft holesSeries ‘C’ 7.4mm between head and shaft holesSeries ‘C’ 9.4mm between head and shaft holesThe 1.0mm ‘T’ Plates have been designed by <strong>Veterinary</strong> <strong>Instrumentation</strong> toprovide options for the repair of distal radial fractures in very small dogsand in cats. These fractures can be difficult to manage, partly because ofthe small sizes of the bones involved and partly because the area hasrelatively poor vascularity resulting in what is often a prolonged healingtime.The spacing between the head holes and the shank holes increases fromthe A-series to the B-series with two extended options in the C-series topermit fracture repair at different levels of the distal radius. As can beseen, the C-series plates have space for a third head screw. This providesgreater repair stability and the C-series are strongly advised when thedistal fragment is large enough. Plate profile on page 391.series holes thickness (mm) length (mm)T101016 A 5 1.0 16 £35.00T101020 A 6 1.0 20 £35.00T101024 A 7 1.0 24 £35.00T101018 B 5 1.0 18 £35.00T101022 B 6 1.0 22 £35.00T101026 B 7 1.0 26 £35.00T101021 C 6 1.0 21 £35.00T101027 C 7 1.0 27 £35.00171

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!