Serverview Trap List
Serverview Trap List Serverview Trap List
92 B Trap List TRAP-TYPE/ Alarm type wfmTempLowWarningOKWar n_LNC_GH Temp Low Warning (OK -> Warn) (LNC_GH) wfmTempLowWarningCritWar n_LC_GL Temp Low Warning (Crit -> Warn) (LC_GL) wfmTempLowCriticalWarnCrit _LC_GH Temp Low Critical(Warn -> Crit) (LC_GH) wfmTempLowCriticalNonReco verCrit_LNR_GL Temp Low Critical(NonRecover -> Crit) (LNR_GL) wfmTempLowCriticalCritNonR ecover_LNR_GH Temp Low Critical(Crit -> NonRecover) (LNR_GH) wfmTempHighWarningOKWar n_UNC_GL Temp High Warning (OK -> Warn) (UNC_GL) wfmTempOK_UNC_GH Temp OK (UNC_GH) wfmTempHighCriticalWarnCrit _UC_GL Temp High Critical(Warn -> Crit) (UC_GL) wfmTempHighWarningCritWar n_UC_GH Temp High Warning (Crit -> Warn) (UC_GH) wfmTempHighCriticalCritNon Recover_UNR_GL Temp High Critical(Crit -> NonRecover) (UNR_GL) wfmTempHighCriticalNonReco verCrit_UNR_GH Temp High Critical(NonRecover -> Crit) (UNR_GH) wfmMemorySingleBitError1 Memory - Single Bit Error 1 wfmVoltageLowWarningOKWa rn_LNC_GL Voltage Low - Warning (OK -> Warn) (LNC_GL) wfmVoltageOK_LNC_GH Voltage OK (LNC_GH) table: INTEL-WFM-MIB Trap (ENTERPRISE : enterprises.3183.1.1) Specific Level of importance 98561 MAJOR %s 98562 MAJOR %s 98563 CRITICAL %s 98564 CRITICAL %s 98565 CRITICAL %s 98566 MAJOR %s 98567 INFORMAT IONAL %s 98568 CRITICAL %s 98569 MAJOR %s 98570 CRITICAL %s 98571 CRITICAL %s 131072 INFORMAT IONAL %s 131328 MAJOR %s 131329 INFORMAT IONAL %s Detailed Messages (%d: optional number %s: system variable) Remarks
TRAP-TYPE/ Alarm type wfmVoltageLowCriticalWarnCr it_LC_GL Voltage Low - Critical(Warn -> Crit) (LC_GL) wfmVoltageLowNoLongerCriti cal_LC_GH Voltage Low - no longer Critical (LC_GH) wfmVoltageLowCriticalCritNo nRecover_LNR_GL Voltage Low - Critical(Crit -> NonRecover) (LNR_GL) wfmVoltageLowCriticalNonRe coverCrit_LNR_GH Voltage Low - Critical(NonRecover -> Crit) (LNR_GH) wfmVoltageOK_UNC_GL Voltage OK (UNC_GL) wfmVoltageHighWarningOKW arn_UNC_GH Voltage High - Warning (OK -> Warn) (UNC_GH) wfmVoltageHighNoLongerCriti cal_UC_GL Voltage High - no longer Critical (UC_GL) wfmVoltageHighCriticalWarnC rit_UC_GH Voltage High - Critical(Warn -> Crit) (UC_GH) wfmVoltageHighCriticalNonRe coverCrit_UNR_GL Voltage High - Critical(NonRecover -> Crit) (UNR_GL) wfmVoltageHighCriticalCritNo nRecover_UNR_GH Voltage High - Critical(Crit -> NonRecover) (UNR_GH) wfmVoltageLimitExceeded Voltage limit exceeded wfmMemorySingleBitError2 Memory - Single Bit Error 2 wfmVoltageOK_LNC_GL Voltage OK (LNC_GL) wfmMemorySingleBitError3 Memory - Single Bit Error 3 wfmVoltageLowWarningOKWa rn_LNC_GH Voltage Low - Warning (OK -> Warn) (LNC_GH) table: INTEL-WFM-MIB Trap (ENTERPRISE : enterprises.3183.1.1) Specific Level of importance 131330 CRITICAL %s 131331 INFORMAT IONAL %s 131332 CRITICAL %s 131333 CRITICAL %s 131334 INFORMAT IONAL %s 131335 MAJOR %s 131336 INFORMAT IONAL %s 131337 CRITICAL %s 131338 CRITICAL %s 131339 CRITICAL %s 132353 CRITICAL %s 133632 INFORMAT IONAL 164096 INFORMAT IONAL 134784 INFORMAT IONAL %s %s %s 164097 MAJOR %s Detailed Messages (%d: optional number %s: system variable) B.36 INTEL-WFM-MIB (WFM.mib ) Remarks 93
- Page 42 and 43: 42 B Trap List TRAP-TYPE/ Alarm typ
- Page 44 and 45: 44 B Trap List TRAP-TYPE/ Alarm typ
- Page 46 and 47: 46 B Trap List TRAP-TYPE/ Alarm typ
- Page 48 and 49: 48 B Trap List TRAP-TYPE/ Alarm typ
- Page 50 and 51: 50 B Trap List TRAP-TYPE/ Alarm typ
- Page 52 and 53: 52 B Trap List B.19 PROMISE-UNIFIED
- Page 54 and 55: 54 B Trap List TRAP-TYPE/ Alarm typ
- Page 56 and 57: 56 B Trap List B.21 UPSMAN (Upsman.
- Page 58 and 59: 58 B Trap List B.23 PowerNet-MIB (p
- Page 60 and 61: 60 B Trap List TRAP-TYPE/ Alarm typ
- Page 62 and 63: 62 B Trap List TRAP-TYPE/ Alarm typ
- Page 64 and 65: 64 B Trap List TRAP-TYPE/ Alarm typ
- Page 66 and 67: 66 B Trap List TRAP-TYPE/ Alarm typ
- Page 68 and 69: 68 B Trap List TRAP-TYPE/ Alarm typ
- Page 70 and 71: 70 B Trap List TRAP-TYPE/ Alarm typ
- Page 72 and 73: 72 B Trap List TRAP-TYPE/ Alarm typ
- Page 74 and 75: 74 B Trap List TRAP-TYPE/ Alarm typ
- Page 76 and 77: 76 B Trap List TRAP-TYPE/ Alarm typ
- Page 78 and 79: 78 B Trap List TRAP-TYPE/ Alarm typ
- Page 80 and 81: 80 B Trap List B.24 Alert-Definitio
- Page 82 and 83: 82 B Trap List B.27 FUJITSU-SERVERV
- Page 84 and 85: 84 B Trap List B.30 SW-MIB (fcswitc
- Page 86 and 87: 86 B Trap List TRAP-TYPE/ Alarm typ
- Page 88 and 89: 88 B Trap List TRAP-TYPE/ Alarm typ
- Page 90 and 91: 90 B Trap List B.34 BRIDGE-MIB (tra
- Page 94 and 95: 94 B Trap List TRAP-TYPE/ Alarm typ
- Page 96 and 97: 96 B Trap List TRAP-TYPE/ Alarm typ
- Page 98 and 99: 98 B Trap List TRAP-TYPE/ Alarm typ
- Page 100 and 101: 100 B Trap List TRAP-TYPE/ Alarm ty
- Page 102 and 103: 102 B Trap List TRAP-TYPE/ Alarm ty
- Page 104 and 105: 104 B Trap List TRAP-TYPE/ Alarm ty
- Page 106 and 107: 106 B Trap List TRAP-TYPE/ Alarm ty
- Page 108 and 109: 108 B Trap List TRAP-TYPE/ Alarm ty
- Page 110 and 111: 110 B Trap List TRAP-TYPE/ Alarm ty
- Page 112 and 113: 112 B Trap List TRAP-TYPE/ Alarm ty
- Page 114 and 115: 114 B Trap List TRAP-TYPE/ Alarm ty
- Page 116 and 117: B Trap List 116
92<br />
B <strong>Trap</strong> <strong>List</strong><br />
TRAP-TYPE/<br />
Alarm type<br />
wfmTempLowWarningOKWar<br />
n_LNC_GH<br />
Temp Low Warning (OK -><br />
Warn) (LNC_GH)<br />
wfmTempLowWarningCritWar<br />
n_LC_GL<br />
Temp Low Warning (Crit -><br />
Warn) (LC_GL)<br />
wfmTempLowCriticalWarnCrit<br />
_LC_GH<br />
Temp Low Critical(Warn -><br />
Crit) (LC_GH)<br />
wfmTempLowCriticalNonReco<br />
verCrit_LNR_GL<br />
Temp Low<br />
Critical(NonRecover -> Crit)<br />
(LNR_GL)<br />
wfmTempLowCriticalCritNonR<br />
ecover_LNR_GH<br />
Temp Low Critical(Crit -><br />
NonRecover) (LNR_GH)<br />
wfmTempHighWarningOKWar<br />
n_UNC_GL<br />
Temp High Warning (OK -><br />
Warn) (UNC_GL)<br />
wfmTempOK_UNC_GH<br />
Temp OK (UNC_GH)<br />
wfmTempHighCriticalWarnCrit<br />
_UC_GL<br />
Temp High Critical(Warn -><br />
Crit) (UC_GL)<br />
wfmTempHighWarningCritWar<br />
n_UC_GH<br />
Temp High Warning (Crit -><br />
Warn) (UC_GH)<br />
wfmTempHighCriticalCritNon<br />
Recover_UNR_GL<br />
Temp High Critical(Crit -><br />
NonRecover) (UNR_GL)<br />
wfmTempHighCriticalNonReco<br />
verCrit_UNR_GH<br />
Temp High<br />
Critical(NonRecover -> Crit)<br />
(UNR_GH)<br />
wfmMemorySingleBitError1<br />
Memory - Single Bit Error 1<br />
wfmVoltageLowWarningOKWa<br />
rn_LNC_GL<br />
Voltage Low - Warning (OK -><br />
Warn) (LNC_GL)<br />
wfmVoltageOK_LNC_GH<br />
Voltage OK (LNC_GH)<br />
table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />
Specific<br />
Level of<br />
importance<br />
98561 MAJOR %s<br />
98562 MAJOR %s<br />
98563 CRITICAL %s<br />
98564 CRITICAL %s<br />
98565 CRITICAL %s<br />
98566 MAJOR %s<br />
98567 INFORMAT<br />
IONAL<br />
%s<br />
98568 CRITICAL %s<br />
98569 MAJOR %s<br />
98570 CRITICAL %s<br />
98571 CRITICAL %s<br />
131072 INFORMAT<br />
IONAL<br />
%s<br />
131328 MAJOR %s<br />
131329 INFORMAT<br />
IONAL<br />
%s<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
Remarks