66<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

atsLostRedundancy<br />

APC Automatic Transfer<br />

Switch: The ATS has lost<br />

redundancy.<br />

atsRedundancyRestored<br />

APC Automatic Transfer<br />

Switch: Redundancy has been<br />

restored.<br />

atsConfigChange<br />

APC Automatic Transfer<br />

Switch: ATS configuration<br />

changed.<br />

atsCommunicationEstablished<br />

APC Automatic Transfer<br />

Switch: Communications<br />

established.<br />

atsCommunicationLost<br />

APC Automatic Transfer<br />

Switch: Communications lost.<br />

atsOverCurrent<br />

APC Automatic Transfer<br />

Switch: Output Current<br />

exceeded threshold.<br />

atsOverCurrentCleared<br />

APC Automatic Transfer<br />

Switch: Output Current below<br />

threshold.<br />

atsPowerSupplyFailure<br />

APC Automatic Transfer<br />

Switch: The ATS Power<br />

Supply has failed.<br />

atsPowerSupplyFailureCleared<br />

APC Automatic Transfer<br />

Switch: Power Supply Failure<br />

Cleared.<br />

dcMainsFailAlarm<br />

APC: A Mains Fail alarm is<br />

active in the DC power plant.<br />

dcMainsFailAlarmCleared<br />

APC: Mains Fail alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcFanFailAlarm<br />

APC: A Fan Fail alarm is<br />

active in the DC power plant.<br />

dcFanFailAlarmCleared<br />

APC: A Fan Fail alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcRectifierOvertempAlarm<br />

APC: Rect. Overtemp alarm is<br />

active in the power plant.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

127 MAJOR The Automatic Transfer Switch has has<br />

lost redundancy.<br />

128 INFORMAT<br />

IONAL<br />

129 INFORMAT<br />

IONAL<br />

130 INFORMAT<br />

IONAL<br />

Redundancy has been restored to the<br />

Automatic Transfer Switch.<br />

A configuration change has been made<br />

on a Automatic Transfer Switch.<br />

Communications with the Automatic<br />

Transfer Switch has been established.<br />

131 MAJOR Communications with the Automatic<br />

Transfer Switch has been lost.<br />

132 MAJOR Output Current has exceeded Threshold.<br />

133 INFORMAT<br />

IONAL<br />

Output Current has returned below<br />

threshold.<br />

134 MAJOR The Automatic Transfer Switch Power<br />

Supply has failed.<br />

135 INFORMAT<br />

IONAL<br />

The Automatic Transfer Switch Power<br />

Supply Failure Cleared.<br />

136 WARNING A Mains Fail alarm is active in the DC<br />

power plant.<br />

137 INFORMAT<br />

IONAL<br />

Mains Fail alarm is no longer active in<br />

the DC power plant.<br />

138 WARNING A Fan Fail alarm is active in the DC<br />

power plant.<br />

139 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A Fan Fail alarm is no longer active in<br />

the DC power plant.<br />

140 WARNING Rect. Overtemp alarm is active in the<br />

power plant.<br />

Remarks