TRAP-TYPE/<br />
Alarm type<br />
upsman<strong>Trap</strong>BatteryBad<br />
UPS: Bad battery<br />
upsman<strong>Trap</strong>TempBad<br />
UPS: Bad temperature<br />
upsman<strong>Trap</strong>TempBadRemoved<br />
UPS: Bad temperatureRemove<br />
upsman<strong>Trap</strong>FatalFault<br />
UPS: Fatal fault<br />
B.22 UPS-MIB (RFC1628.mib)<br />
<strong>Trap</strong>s from NetpowerView F. Refer to the NetpowerView F manual for details.<br />
TRAP-TYPE/<br />
Alarm type<br />
ups<strong>Trap</strong>OnBattery<br />
UPS on Battery<br />
ups<strong>Trap</strong>TestCompleted<br />
UPS Test Completed<br />
ups<strong>Trap</strong>AlarmEntryAdded<br />
UPS Alarm Entry Added<br />
ups<strong>Trap</strong>AlarmEntryRemoved<br />
UPS Alarm Entry Removed<br />
table: UPSMAN trap (ENTERPRISE : enterprises.1356)<br />
Specific<br />
B.22 UPS-MIB (RFC1628.mib)<br />
14 MAJOR Bad battery Battery replacement<br />
necessary.<br />
15 MAJOR Bad temperature Temperature is<br />
beyond the<br />
specification range. It<br />
is not necessary to<br />
identify the place<br />
where the<br />
temperature error<br />
occurred.<br />
For details about the<br />
content of<br />
temperature errors,<br />
refer to<br />
upsAlarmTempBadD<br />
etail.<br />
16 INFORMAT<br />
IONAL<br />
Bad temperatureRemove Temperature has<br />
returned to within the<br />
specification range.<br />
17 CRITICAL Fatal fault UPS fatal fault<br />
occurred.<br />
This appears when a<br />
fatal fault that makes<br />
running on backup<br />
power impossible has<br />
occurred in the UPS.<br />
table: UPS-MIB <strong>Trap</strong> (ENTERPRISE : mib2.33.2)<br />
Specific<br />
Level of<br />
importance<br />
Level of<br />
importance<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
1 CRITICAL The UPS is on battery power since %d<br />
seconds<br />
2 INFORMAT<br />
IONAL<br />
3 INFORMAT<br />
IONAL<br />
4 INFORMAT<br />
IONAL<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
This trap is sent upon completion of a<br />
UPS diagnostic test.<br />
This trap is sent each time an alarm is<br />
inserted into to the alarm table. It is sent<br />
on the insertion of all alarms except for<br />
upsAlarmOnBattery and<br />
upsAlarmTestInProgress.<br />
This trap is sent each time an alarm is<br />
removed from the alarm table. It is sent<br />
on the removal of all alarms except for<br />
upsAlarmTestInProgress.<br />
Remarks<br />
Remarks<br />