TRAP-TYPE/<br />

Alarm type<br />

upsman<strong>Trap</strong>BatteryBad<br />

UPS: Bad battery<br />

upsman<strong>Trap</strong>TempBad<br />

UPS: Bad temperature<br />

upsman<strong>Trap</strong>TempBadRemoved<br />

UPS: Bad temperatureRemove<br />

upsman<strong>Trap</strong>FatalFault<br />

UPS: Fatal fault<br />

B.22 UPS-MIB (RFC1628.mib)<br />

<strong>Trap</strong>s from NetpowerView F. Refer to the NetpowerView F manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

ups<strong>Trap</strong>OnBattery<br />

UPS on Battery<br />

ups<strong>Trap</strong>TestCompleted<br />

UPS Test Completed<br />

ups<strong>Trap</strong>AlarmEntryAdded<br />

UPS Alarm Entry Added<br />

ups<strong>Trap</strong>AlarmEntryRemoved<br />

UPS Alarm Entry Removed<br />

table: UPSMAN trap (ENTERPRISE : enterprises.1356)<br />

Specific<br />

B.22 UPS-MIB (RFC1628.mib)<br />

14 MAJOR Bad battery Battery replacement<br />

necessary.<br />

15 MAJOR Bad temperature Temperature is<br />

beyond the<br />

specification range. It<br />

is not necessary to<br />

identify the place<br />

where the<br />

temperature error<br />

occurred.<br />

For details about the<br />

content of<br />

temperature errors,<br />

refer to<br />

upsAlarmTempBadD<br />

etail.<br />

16 INFORMAT<br />

IONAL<br />

Bad temperatureRemove Temperature has<br />

returned to within the<br />

specification range.<br />

17 CRITICAL Fatal fault UPS fatal fault<br />

occurred.<br />

This appears when a<br />

fatal fault that makes<br />

running on backup<br />

power impossible has<br />

occurred in the UPS.<br />

table: UPS-MIB <strong>Trap</strong> (ENTERPRISE : mib2.33.2)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1 CRITICAL The UPS is on battery power since %d<br />

seconds<br />

2 INFORMAT<br />

IONAL<br />

3 INFORMAT<br />

IONAL<br />

4 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

This trap is sent upon completion of a<br />

UPS diagnostic test.<br />

This trap is sent each time an alarm is<br />

inserted into to the alarm table. It is sent<br />

on the insertion of all alarms except for<br />

upsAlarmOnBattery and<br />

upsAlarmTestInProgress.<br />

This trap is sent each time an alarm is<br />

removed from the alarm table. It is sent<br />

on the removal of all alarms except for<br />

upsAlarmTestInProgress.<br />

Remarks<br />