B <strong>Trap</strong> <strong>List</strong><br />

B.21 UPSMAN (Upsman.mib)<br />

<strong>Trap</strong>s from NetpowerView F. Refer to the NetpowerView F manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

communicationLost<br />

UPS: Communication failure<br />

upsOverload<br />

UPS: UPS overload<br />

upsTurnedOff<br />

UPS: Switching off<br />

communicationEstablished<br />

UPS: Communication<br />

established<br />

powerRestored<br />

UPS: power restored<br />

upsOnBattery<br />

UPS: On battery<br />

testStarted<br />

UPS: Test started<br />

testCompleted<br />

UPS: Test completed<br />

upsBatteryLow<br />

UPS: Battery Low<br />

upsShutdownImminent<br />

UPS: Shutdown Imminent<br />

upsmanStarted<br />

UPS: UpsMan service started<br />

upsman<strong>Trap</strong>InputBad<br />

UPS: Abnormal input<br />

condition<br />

upsman<strong>Trap</strong>OutputOverloadR<br />

emoved<br />

UPS: Overload Removed<br />

table: UPSMAN trap (ENTERPRISE : enterprises.1356)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1 CRITICAL Communication with the UPS has been<br />

lost.<br />

2 CRITICAL The UPS has sensed a load greater than<br />

100 percent of its rated capacity.<br />

3 MAJOR The UPS is being switched off by a<br />

management station.<br />

4 INFORMAT<br />

IONAL<br />

5 INFORMAT<br />

IONAL<br />

Communication with the UPS has been<br />

established.<br />

Normal power has been restored to the<br />

UPS.<br />

6 MAJOR The UPS system has switched to battery<br />

backup power.<br />

7 INFORMAT<br />

IONAL<br />

8 INFORMAT<br />

IONAL<br />

Remarks<br />

There is an error in<br />

communication<br />

between the agent and<br />

UPS.<br />

UPS output overload<br />

has occurred.<br />

UPS output is<br />

switched off.<br />

Communication<br />

between the agent<br />

and UPS has been reestablished.<br />

UPS power voltage<br />

has returned to within<br />

the specification<br />

range.<br />

UPS is running on<br />

backup power.<br />

This trap will be sent<br />

in the one minute<br />

period until the UPS<br />

has stopped or<br />

running on backup<br />

power is stopped.<br />

UPS test has been started. This signals the start<br />

of UPS test.<br />

UPS test has been completed. This signals the end<br />

of UPS test.<br />

9 MAJOR UPS Battery Low. The battery capacity<br />

is low.<br />

Refer to<br />

upsBatteryStatus. The<br />

repeat value depends<br />

on<br />

upsConfigIntervalTra<br />

pTime.<br />

10 INFORMAT<br />

IONAL<br />

11 INFORMAT<br />

IONAL<br />

UPS Shutdown Imminent. Signals there is one<br />

minute to server<br />

shutdown.<br />

UpsMan service started. Start service.<br />

12 MAJOR Abnormal input condition UPS power voltage is<br />

beyond the<br />

specification range.<br />

13 INFORMAT<br />

IONAL<br />

Overload Removed UPS output overload<br />

has removed.