Serverview Trap List
Serverview Trap List
Serverview Trap List
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
TRAP-TYPE/<br />
Alarm type<br />
dptHbaNoSpares<strong>Trap</strong><br />
No hot spares detected on<br />
controller<br />
dptDevStatusChanged2<strong>Trap</strong><br />
Device status change<br />
dptBatteryChange2<strong>Trap</strong><br />
Battery status change.<br />
dptOther<strong>Trap</strong><br />
Controller generated an event<br />
108 INFORMAT<br />
IONAL<br />
109 INFORMAT<br />
IONAL<br />
110 INFORMAT<br />
IONAL<br />
14 INFORMAT<br />
IONAL<br />
No available hot spares were detected<br />
during a scan on controller %d<br />
B.16 MYLEXRAID-MIB (Mlxraid.mib)<br />
Device status on Controller %d Bus %d<br />
ID %d LUN %d : %s.<br />
Battery status is now %s on controller<br />
%d.<br />
Controller generated event: %s<br />
B.16 MYLEXRAID-MIB (Mlxraid.mib)<br />
<strong>Trap</strong>s from the Mylex Disk Array Controller. For message details, refer to the RAID controller (RAID<br />
Manager (GAM: Global Array Manager)) manual.<br />
B.17 MYLEXRAID-FJ-MIB (Mlxraidfj.mib)<br />
<strong>Trap</strong>s from the Mylex Disk Array Controller. For message details, refer to the RAID controller (RAID<br />
Manager (GAM: Global Array Manager)) manual.<br />
B.18 FASTTRAK-MIB (promisev1.mib)<br />
<strong>Trap</strong>s from Promise IDE RAID Adapter. Refer to the RAID controller(RAID<br />
Manager(FastCheckMonitor)) manual for details.<br />
TRAP-TYPE/<br />
Alarm type<br />
trpUnknown<br />
Unknown - possibly new<br />
driver error code<br />
trpEccError<br />
ECC Error on Disk <br />
LBA <br />
trpDiskDown<br />
Disk Down <br />
trpDiskOffline<br />
Disk Offline <br />
trpDiskPlugin<br />
Disk Plugin <br />
trpAryBadSector<br />
Array had BadSector<br />
at LBA <br />
table: ADAPTECDURALINK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.1597)<br />
Specific<br />
table: FASTTRAK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7933.2.12)<br />
Specific<br />
Level of<br />
importance<br />
Level of<br />
importance<br />
1 INFORMAT<br />
IONAL<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
Unknown<br />
2 CRITICAL ECC Error on Disk<br />
3 MAJOR Disk Set Down by Driver<br />
4 MAJOR Disk %d of array %d set offline by driver.<br />
Description: %d<br />
5 MINOR New Disk Plugged In<br />
6 INFORMAT<br />
IONAL<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
Bad sector encountered<br />
Remarks<br />
Remarks<br />
49