48 B Trap List TRAP-TYPE/ Alarm type dptDevArrayDataInconsistenc yTrap Array data inconsistency found. dptHbaErrorTrap controller error found. dptDevFailedTrap Unprotected drive has failed. dptDevSmartFailedTrap SMART failure reported. dptHbaAuxVoltageChangeTrap Auxiliary voltage outside range on controller dptHbaVoltageChange2Trap 5V Voltage outside range on controller dptHbaAuxVoltageChange2Tr ap Auxiliary voltage outside range on controller dptHbaEccRAMErrorCorrecte dTrap ECC RAM Error detected and corrected. dptDevBlockReassignedTrap Disk block was reassigned dptDevReqSenseErrorTrap Warning: request sense data received. dptHbaVoltageNormalTrap Normal 5V voltage on controller dptHbaTemperatureNormalTr ap Normal temperature on controller dptHbaEccRAMErrorNotFou ndTrap ECC RAM Error detected but not found on correction. dptDevStatusChangedTrap Device status change dptDevReqSenseTrap Request sense received from controller. dptArrayChangeTrap Array change. dptBatteryChangeTrap Battery status change. dptHbaAuxVoltageNormalTrap Normal auxiliary voltage on controller table: ADAPTECDURALINK-MIB Trap (ENTERPRISE : enterprises.1597) Specific Level of importance 305 MAJOR Array Data Inconsistency: Controller %d Bus %d ID %d LUN %d. 306 MAJOR controller %d reported a non-SCSI related error. 307 MAJOR Drive failure on controller %d Bus %d ID %d LUN %d. 308 MAJOR SMART failure on controller %d Bus %d ID %d LUN %d reported. 309 MAJOR An auxiliary voltage status is now %d on controller %d 310 MAJOR 5V Voltage status is now %s on controller %d 311 MAJOR An auxiliary voltage status is now %s on controller %d 200 MINOR Correctable ECC RAM Error detected on controller %d 201 MINOR Block %d reassigned: Controller %d Bus %d ID %d LUN %d 202 MINOR Warning: Request sense data for controller %d Bus %d ID %d LUN %d. 100 INFORMAT IONAL 101 INFORMAT IONAL 102 INFORMAT IONAL 103 INFORMAT IONAL 104 INFORMAT IONAL 105 INFORMAT IONAL 106 INFORMAT IONAL 107 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) Normal 5V voltage restored on controller %d Normal temperature restored on controller %d ECC RAM Error detected at %d on controller %d, but not found. Device status on Controller %d Bus %d ID %d LUN %d : %d. Request sense data for controller %d Bus %d ID %d LUN %d. Array change on controller %d Bus %d ID %d LUN %d. Battery status is now %d on controller %d. Normal auxiliary voltage restored on controller %d Remarks

TRAP-TYPE/ Alarm type dptHbaNoSparesTrap No hot spares detected on controller dptDevStatusChanged2Trap Device status change dptBatteryChange2Trap Battery status change. dptOtherTrap Controller generated an event 108 INFORMAT IONAL 109 INFORMAT IONAL 110 INFORMAT IONAL 14 INFORMAT IONAL No available hot spares were detected during a scan on controller %d B.16 MYLEXRAID-MIB (Mlxraid.mib) Device status on Controller %d Bus %d ID %d LUN %d : %s. Battery status is now %s on controller %d. Controller generated event: %s B.16 MYLEXRAID-MIB (Mlxraid.mib) Traps from the Mylex Disk Array Controller. For message details, refer to the RAID controller (RAID Manager (GAM: Global Array Manager)) manual. B.17 MYLEXRAID-FJ-MIB (Mlxraidfj.mib) Traps from the Mylex Disk Array Controller. For message details, refer to the RAID controller (RAID Manager (GAM: Global Array Manager)) manual. B.18 FASTTRAK-MIB (promisev1.mib) Traps from Promise IDE RAID Adapter. Refer to the RAID controller(RAID Manager(FastCheckMonitor)) manual for details. TRAP-TYPE/ Alarm type trpUnknown Unknown - possibly new driver error code trpEccError ECC Error on Disk LBA trpDiskDown Disk Down trpDiskOffline Disk Offline trpDiskPlugin Disk Plugin trpAryBadSector Array had BadSector at LBA table: ADAPTECDURALINK-MIB Trap (ENTERPRISE : enterprises.1597) Specific table: FASTTRAK-MIB Trap (ENTERPRISE : enterprises.7933.2.12) Specific Level of importance Level of importance 1 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) Unknown 2 CRITICAL ECC Error on Disk 3 MAJOR Disk Set Down by Driver 4 MAJOR Disk %d of array %d set offline by driver. Description: %d 5 MINOR New Disk Plugged In 6 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) Bad sector encountered Remarks Remarks 49

48<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

dptDevArrayDataInconsistenc<br />

y<strong>Trap</strong><br />

Array data inconsistency<br />

found.<br />

dptHbaError<strong>Trap</strong><br />

controller error found.<br />

dptDevFailed<strong>Trap</strong><br />

Unprotected drive has failed.<br />

dptDevSmartFailed<strong>Trap</strong><br />

SMART failure reported.<br />

dptHbaAuxVoltageChange<strong>Trap</strong><br />

Auxiliary voltage outside<br />

range on controller<br />

dptHbaVoltageChange2<strong>Trap</strong><br />

5V Voltage outside range on<br />

controller<br />

dptHbaAuxVoltageChange2Tr<br />

ap<br />

Auxiliary voltage outside<br />

range on controller<br />

dptHbaEccRAMErrorCorrecte<br />

d<strong>Trap</strong><br />

ECC RAM Error detected and<br />

corrected.<br />

dptDevBlockReassigned<strong>Trap</strong><br />

Disk block was reassigned<br />

dptDevReqSenseError<strong>Trap</strong><br />

Warning: request sense data<br />

received.<br />

dptHbaVoltageNormal<strong>Trap</strong><br />

Normal 5V voltage on<br />

controller<br />

dptHbaTemperatureNormalTr<br />

ap<br />

Normal temperature on<br />

controller<br />

dptHbaEccRAMErrorNotFou<br />

nd<strong>Trap</strong><br />

ECC RAM Error detected but<br />

not found on correction.<br />

dptDevStatusChanged<strong>Trap</strong><br />

Device status change<br />

dptDevReqSense<strong>Trap</strong><br />

Request sense received from<br />

controller.<br />

dptArrayChange<strong>Trap</strong><br />

Array change.<br />

dptBatteryChange<strong>Trap</strong><br />

Battery status change.<br />

dptHbaAuxVoltageNormal<strong>Trap</strong><br />

Normal auxiliary voltage on<br />

controller<br />

table: ADAPTECDURALINK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.1597)<br />

Specific<br />

Level of<br />

importance<br />

305 MAJOR Array Data Inconsistency: Controller %d<br />

Bus %d ID %d LUN %d.<br />

306 MAJOR controller %d reported a non-SCSI related<br />

error.<br />

307 MAJOR Drive failure on controller %d Bus %d<br />

ID %d LUN %d.<br />

308 MAJOR SMART failure on controller %d Bus %d<br />

ID %d LUN %d reported.<br />

309 MAJOR An auxiliary voltage status is now %d on<br />

controller %d<br />

310 MAJOR 5V Voltage status is now %s on controller<br />

%d<br />

311 MAJOR An auxiliary voltage status is now %s on<br />

controller %d<br />

200 MINOR Correctable ECC RAM Error detected on<br />

controller %d<br />

201 MINOR Block %d reassigned: Controller %d Bus<br />

%d ID %d LUN %d<br />

202 MINOR Warning: Request sense data for<br />

controller %d Bus %d ID %d LUN %d.<br />

100 INFORMAT<br />

IONAL<br />

101 INFORMAT<br />

IONAL<br />

102 INFORMAT<br />

IONAL<br />

103 INFORMAT<br />

IONAL<br />

104 INFORMAT<br />

IONAL<br />

105 INFORMAT<br />

IONAL<br />

106 INFORMAT<br />

IONAL<br />

107 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Normal 5V voltage restored on controller<br />

%d<br />

Normal temperature restored on<br />

controller %d<br />

ECC RAM Error detected at %d on<br />

controller %d, but not found.<br />

Device status on Controller %d Bus %d ID<br />

%d LUN %d : %d.<br />

Request sense data for controller %d Bus<br />

%d ID %d LUN %d.<br />

Array change on controller %d Bus %d<br />

ID %d LUN %d.<br />

Battery status is now %d on controller<br />

%d.<br />

Normal auxiliary voltage restored on<br />

controller %d<br />