TRAP-TYPE/<br />

Alarm type<br />

sniShortCurcuit<br />

Short circuit in the mouse,<br />

keyboard or USB interface.<br />

sniTemperatureOK<br />

The temperature sensor is<br />

functioning<br />

sniTemperatureWarning<br />

The temperature is high<br />

sniTemperatureCritical<br />

The temperature sensor is<br />

defective or the temperature is<br />

too high<br />

sniFanRunning<br />

The fan is running<br />

sniFanNotRunning<br />

The fan is not running<br />

sniFanWornOK<br />

The rotational speed of the fan<br />

is OK.<br />

sniFanWornWarning<br />

The rotational speed of the fan<br />

is almost critical.<br />

sniFanWornCritical<br />

The rotational speed of the fan<br />

is critical.<br />

sniVoltageOk<br />

The voltage monitor is<br />

functioning.<br />

sniVoltageWarning<br />

The voltage is almost critical.<br />

sniVoltageCritical<br />

The voltage monitor is not<br />

functioning or the voltage is<br />

critical.<br />

sniWatchdogOk<br />

The functionality of the<br />

operating system watchdog is<br />

guaranteed.<br />

sniWatchdogCritical<br />

The operating system<br />

watchdog caused too many<br />

consecutive system reboots<br />

and will be deactivated.<br />

sniInternalError<br />

Messages for system<br />

monitoring got lost because<br />

they could not be buffered!.<br />

The buffer has overrun or the<br />

harddisk was full.<br />

sniBIOSErrorLogOK<br />

BIOS error log contains no<br />

current entries<br />

table: DESKTRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.3)<br />

Specific<br />

Level of<br />

importance<br />

5003 CRITICAL Short circuit in the mouse, keyboard or<br />

USB interface on %s<br />

7001 INFORMAT<br />

IONAL<br />

The temperature sensor is functioning on<br />

%s<br />

7002 MINOR The temperature is high on %s ↑<br />

7003 CRITICAL The temperature sensor is defective or<br />

the temperature is too high on %s<br />

8001 INFORMAT<br />

IONAL<br />

The fan is running on %s ↑<br />

8003 CRITICAL The fan is not running on %s ↑<br />

9001 INFORMAT<br />

IONAL<br />

The rotational speed of the fan is OK on<br />

%s<br />

9002 MINOR The rotational speed of the fan is almost<br />

critical on %s<br />

9003 CRITICAL The rotational speed of the fan is critical<br />

on %s<br />

11001 INFORMAT<br />

IONAL<br />

The voltage monitor is functioning on %s ↑<br />

11002 MINOR The voltage is almost critical on %s ↑<br />

11003 CRITICAL The voltage monitor is not functioning or<br />

the voltage is critical on %s<br />

12001 INFORMAT<br />

IONAL<br />

The functionality of the operating system<br />

watchdog is guaranteed on %s<br />

12003 CRITICAL The operating system watchdog caused<br />

too many consecutive system reboots and<br />

will be deactivated on %s<br />

13001 MINOR Messages for system monitoring got lost<br />

because they could not be buffered!. The<br />

buffer has overrun or the harddisk was<br />

full on %s.<br />

14001 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

BIOS error log contains no current<br />

entries on %s<br />

B.14 DESKTRAP-MIB (desktrap.mib)<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks<br />

43