Serverview Trap List Serverview Trap List

13.08.2012 Views

40 B Trap List TRAP-TYPE/ Alarm type aacControllerPaused Controller paused aacContainerCreated Container created aacContainerDeleted Container deleted aacDeviceFailurePredictionTh resholdExceeded Device failure prediction threshold exceeded aacDeviceFailurePredictionTe st Device failure prediction test aacDeviceWarning Device warning aacDeviceTemperatureWarning Device temperature warning aacDeviceDegradedWarning Device degraded warning aacDeviceFailurePredictionCo nfigurationChanged Device failure prediction configuration changed aacGlobalHotSpareReplacedS uccess Failover Replaced aacDedicatedHotSpareReplac edSuccess Failover Replaced aacGlobalHotSpareReplacedT ooSmall Failover Replaced aacDedicatedHotSpareReplac edTooSmall Failover Replaced aacDedicatedHotSpareReplac edArrayNotExist Failover Replaced aacBatteryTemperatureWarning Battery Temperature Warning aacBatteryTemperatureCritical Battery Temperature Critical aacBatteryTemperatureCritical Recover Battery Temperature Critical Recover table: AdaptecArrayController-MIB Trap (ENTERPRISE : enterprises.795.10.1.1) Specific Level of importance 35 MINOR The controller %s has been paused. 36 INFORMAT IONAL 37 INFORMAT IONAL Container %d has been created on controller %s. Container %d has been deleted on controller %s. 38 MAJOR A device reported that its Failure Prediction Threshold had been exceeded. Controller %s. Bus %d. ID %d LUN %d. 39 INFORMAT IONAL A Failure Prediction Threshold test occurred. Controller %s. Bus %d. ID %d. LUN %d. 40 MAJOR A Device issued a warning. Controller %s. Bus %d. ID %d LUN %d. 41 MAJOR A Device issued a abnormal temperature warning. Controller %s. Bus %d. ID %d LUN %d. 42 MINOR A device reported that its status is degraded. Controller %s. Bus %d. ID %d LUN %d. 43 INFORMAT IONAL 44 INFORMAT IONAL 45 INFORMAT IONAL The failure prediction configuration changed for a device. Controller %s. Bus %d. ID %d LUN %d. A failover device has been replaced on controller %s. A failover device has been replaced on container %d, controller %s. 46 WARNING The failover device that was replaced on controller %s is too small. 47 WARNING The failover device that was replaced on container %d, controller %s is too small. 48 WARNING The failover device has been replaced on container %d, controller %s. However, container %d does not exist. 49 WARNING The battery connected to controller %s has reported an over temperature warning. 50 CRITICAL The battery connected to controller %s, has reported that it is critically over temperature. 51 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) The battery connected to controller %s, has reported that it has recovered from a critical over temperature. Remarks

TRAP-TYPE/ Alarm type aacBatteryTemperatureNormal Battery Temperature Warning Recover aacContainerMetadataUnkno wnError Container Metadata Unknown Error aacContainerMetadataReadErr or A metadata read error has occurred aacContainerMetadataCRCFai lureError Container Metadata CRC Failure Error aacContainerMiscompareError Container Miscompare Error aacSCSIBusReset There has been a SCSI bus reset aacSenseData Sense data event aacMediumError There has been a device medium error aacBadBlockRecoveryStarting The bad block recovery has started. aacBadBlockRecoveryComple ting The bad block recovery has completed aacInvalidIO An invalid I/O event has occurred aacDisablingChannel Disabling channel event aacCannotReadyDevice System can not ready the device aacChannelTimeout Channel Timeout aacSenseDataUnknown Sense data event aacCommandTimeout A command timeout has occurred 52 INFORMAT IONAL B.13 AdaptecArrayController-MIB (aac.mib) table: AdaptecArrayController-MIB Trap (ENTERPRISE : enterprises.795.10.1.1) Specific Level of importance The battery connected to controller %s, has returned to normal. 53 CRITICAL Container %d has experienced an unknown metadata error on controller %s. 54 CRITICAL A metadata read error has occurred. Controller %s. Bus %d. ID %d LUN %d. 55 CRITICAL A metadata CRC faiure has occurred. Controller %s. Bus %d. ID %d LUN %d. 56 CRITICAL Container %d has experienced miscompare error(s) on controller %s. 57 INFORMAT IONAL 58 INFORMAT IONAL There has been a SCSI bus reset. Controller %s. Bus %d. A sense data event has occurred. Controller %s. Bus %d. ID %d LUN %d. Key %s. ASC %s ASCQ %s. 59 MAJOR There has been a device medium error. Controller %s. Bus %d. ID %d LUN %d. Begin LBA %s End LBA %s. 60 INFORMAT IONAL 61 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) The bad block recovery has started. Controller %s. Bus %d. ID %d LUN %d. The bad block recovery has completed. Controller %s. Bus %d. ID %d LUN %d. 62 MAJOR An invalid I/O event has occurred. Controller %s. Bus %d. ID %d LUN %d. Expected Bytes %d, Actual Bytes %d. 63 MINOR A disabling channel event has occurred. Controller %s. Bus %d. Error Code %d 64 MAJOR The system can not ready the device. Controller %s. Bus %d. ID %d LUN %d. 65 MAJOR A channel timeout has occurred. Controller %s. Bus %d. 66 MAJOR A sense data event has occurred. Controller %s. Bus %d. ID %d LUN %d. Key %s. ASC %s ASCQ %s. 67 MAJOR A command timeout has occurred. Controller %s. Bus %d. ID %d LUN %d. OpCode %s. Remarks 41

TRAP-TYPE/<br />

Alarm type<br />

aacBatteryTemperatureNormal<br />

Battery Temperature Warning<br />

Recover<br />

aacContainerMetadataUnkno<br />

wnError<br />

Container Metadata Unknown<br />

Error<br />

aacContainerMetadataReadErr<br />

or<br />

A metadata read error has<br />

occurred<br />

aacContainerMetadataCRCFai<br />

lureError<br />

Container Metadata CRC<br />

Failure Error<br />

aacContainerMiscompareError<br />

Container Miscompare Error<br />

aacSCSIBusReset<br />

There has been a SCSI bus<br />

reset<br />

aacSenseData<br />

Sense data event<br />

aacMediumError<br />

There has been a device<br />

medium error<br />

aacBadBlockRecoveryStarting<br />

The bad block recovery has<br />

started.<br />

aacBadBlockRecoveryComple<br />

ting<br />

The bad block recovery has<br />

completed<br />

aacInvalidIO<br />

An invalid I/O event has<br />

occurred<br />

aacDisablingChannel<br />

Disabling channel event<br />

aacCannotReadyDevice<br />

System can not ready the<br />

device<br />

aacChannelTimeout<br />

Channel Timeout<br />

aacSenseDataUnknown<br />

Sense data event<br />

aacCommandTimeout<br />

A command timeout has<br />

occurred<br />

52 INFORMAT<br />

IONAL<br />

B.13 AdaptecArrayController-MIB (aac.mib)<br />

table: AdaptecArrayController-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.10.1.1)<br />

Specific<br />

Level of<br />

importance<br />

The battery connected to controller %s,<br />

has returned to normal.<br />

53 CRITICAL Container %d has experienced an<br />

unknown metadata error on controller<br />

%s.<br />

54 CRITICAL A metadata read error has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

55 CRITICAL A metadata CRC faiure has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

56 CRITICAL Container %d has experienced<br />

miscompare error(s) on controller %s.<br />

57 INFORMAT<br />

IONAL<br />

58 INFORMAT<br />

IONAL<br />

There has been a SCSI bus reset.<br />

Controller %s. Bus %d.<br />

A sense data event has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Key %s. ASC %s ASCQ %s.<br />

59 MAJOR There has been a device medium error.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Begin LBA %s End LBA %s.<br />

60 INFORMAT<br />

IONAL<br />

61 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The bad block recovery has started.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

The bad block recovery has completed.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

62 MAJOR An invalid I/O event has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Expected Bytes %d, Actual Bytes %d.<br />

63 MINOR A disabling channel event has occurred.<br />

Controller %s. Bus %d. Error Code %d<br />

64 MAJOR The system can not ready the device.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

65 MAJOR A channel timeout has occurred.<br />

Controller %s. Bus %d.<br />

66 MAJOR A sense data event has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Key %s. ASC %s ASCQ %s.<br />

67 MAJOR A command timeout has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

OpCode %s.<br />

Remarks<br />