Serverview Trap List

Serverview Trap List Serverview Trap List

13.08.2012 Views

34 B Trap List table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises.231.2.10.2.2.10.20) TRAP-TYPE/ Alarm type sc2TrapMemErrorModulePrefail Memory module prefailure sc2TrapMemErrorModuleFailing Memory module failing sc2TrapMemErrorModuleReplaced Memory module replaced sc2TrapCpuSpeedChanged CPU speed changed sc2TrapCpuPrefail CPU prefailure sc2TrapCabinetSwitchedOff Cabinet switched off sc2TrapCabinetSwitchedOn Cabinet switched on sc2TrapPowerOffTimeReached Power off time reached sc2TrapServerShutdown Server shutdown sc2TrapShutdownCancelled Shutdown cancelled sc2TrapBootRetryCountZero Boot retry counter zero sc2TrapMessageLogFull Message log full sc2TrapMessageLogWarning Message log warning sc2TrapBootMessageLogEntry Error in message log sc2TrapIntrusionAssertion Front door or housing opened sc2TrapIntrusionDeassertion Front door or housing closed sc2TrapIntrusionChanged Front door or housing opened/closed Specific Level of importance 2068 MAJOR Memory module failure is predicted for module %s in cabinet %d of server %s. 2069 MAJOR Memory module %s in cabinet %d of server %s is failing. Too many errors have occured. 2070 MAJOR Memory module module %s in cabinet %d of server %s had failed and was replaced by a hot-spare module 2080 INFORMAT IONAL CPU speed at server %s changed to %d percent of its maximum speed. 2081 MAJOR CPU failure is predicted for CPU %s in cabinet %d of server %s. 2090 INFORMAT IONAL 2091 INFORMAT IONAL 2092 INFORMAT IONAL 2093 INFORMAT IONAL 2094 INFORMAT IONAL Cabinet %d was switched off because of %s (server %s). Cabinet %d was switched on because of %s (server %s). The power-off time is reached in cabinet %d on server %s! System shutdown in %d minutes. The reason %s causes a shutdown at server %s. Shutdown at server %s cancelled by the user. 2095 MAJOR Boot retry counter is zero on server %s. 2100 MINOR The System Event Log on server %s in cabinet %d is full. No more messages can be logged! Please clear unneeded log entries as soon as possible! 2101 MINOR The System Event Log for cabinet %d at server %s has exceeded %d%% of its capacity. 2102 MAJOR An error was recorded on server %s before the management agents were started (boot phase). See server management message log (Recovery log) for detailed information. 2110 MAJOR The front door or housing of cabinet %d was opened on server %s. 2111 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) The front door or housing of cabinet %d was closed on server %s. 2112 MAJOR The front door or housing of cabinet %d was opened or closed on server %s. Remarks

B.12 BLADE-MIB (S31.mib) Traps from blade server (BX300/BX600). Refer to the blade server manual for details. TRAP-TYPE/ Alarm type s31TestTrap Test trap s31MgmtBladeAdded Management blade added s31MgmtBladeRemoved Management blade removed s31MgmtBladeOk Status of management blade is OK s31MgmtBladeError Status of management blade is error s31MgmtBladeCriticalError Status of management blade is critical s31ServerBladeAdded Server blade added s31ServerBladeRemoved Server blade removed s31ServerBladeOk Status of server blade is OK s31ServerBladeError Status of server blade is error s31ServerBladeCriticalError Status of server blade is critical s31SwitchBladeAdded Switch blade added s31SwitchBladeRemoved Switch blade removed s31SwitchBladeOk Status of switch blade is OK s31SwitchBladeError Status of switch blade is error s31SwitchBladeCriticalError Status of switch blade is critical s31SysFanAdded System fan added s31SysFanRemoved System fan removed s31SysFanOk Status of system fan is OK s31SysFanError Status of system fan is error s31SysFanCriticalError Status of system fan is critical table: BLADE-MIB Trap (ENTERPRISE : enterprises.7244.1.1.1) Specific Level of importance 1600 INFORMAT IONAL 1601 INFORMAT IONAL 1602 INFORMAT IONAL 1603 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) Test trap from blade chassis %s (no error). Management blade %d at blade chassis %s was added. Management blade %d at blade chassis %s was removed. Management blade %d at blade chassis %s status is ok. 1604 MAJOR Management blade %d at blade chassis %s status is error. 1605 CRITICAL Management blade %d at blade chassis %s status is critical. 1606 INFORMAT IONAL 1607 INFORMAT IONAL 1608 INFORMAT IONAL Server blade %d at blade chassis %s was added. Server blade %d at blade chassis %s was removed. Server blade %d at blade chassis %s status is OK. 1609 MAJOR Server blade %d at blade chassis %s status is error. 1610 CRITICAL Server blade %d at blade chassis %s status is critical. 1611 INFORMAT IONAL 1612 INFORMAT IONAL 1613 INFORMAT IONAL Switch blade %d at blade chassis %s was added. Switch blade %d at blade chassis %s was removed. Switch blade %d at blade chassis %s status is OK. 1614 MAJOR Switch blade %d at blade chassis %s status is error. 1615 CRITICAL Switch blade %d at blade chassis %s status is critical. 1616 INFORMAT IONAL 1617 INFORMAT IONAL 1618 INFORMAT IONAL System fan %d at blade chassis %s was added. System fan %d at blade chassis %s was removed. System fan %d at blade chassis %s status is OK. 1619 MAJOR System fan %d at blade chassis %s status is error. 1620 CRITICAL System fan %d at blade chassis %s status is critical. B.12 BLADE-MIB (S31.mib) Remarks 35

B.12 BLADE-MIB (S31.mib)<br />

<strong>Trap</strong>s from blade server (BX300/BX600). Refer to the blade server manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

s31Test<strong>Trap</strong><br />

Test trap<br />

s31MgmtBladeAdded<br />

Management blade added<br />

s31MgmtBladeRemoved<br />

Management blade removed<br />

s31MgmtBladeOk<br />

Status of management blade is<br />

OK<br />

s31MgmtBladeError<br />

Status of management blade is<br />

error<br />

s31MgmtBladeCriticalError<br />

Status of management blade is<br />

critical<br />

s31ServerBladeAdded<br />

Server blade added<br />

s31ServerBladeRemoved<br />

Server blade removed<br />

s31ServerBladeOk<br />

Status of server blade is OK<br />

s31ServerBladeError<br />

Status of server blade is error<br />

s31ServerBladeCriticalError<br />

Status of server blade is<br />

critical<br />

s31SwitchBladeAdded<br />

Switch blade added<br />

s31SwitchBladeRemoved<br />

Switch blade removed<br />

s31SwitchBladeOk<br />

Status of switch blade is OK<br />

s31SwitchBladeError<br />

Status of switch blade is error<br />

s31SwitchBladeCriticalError<br />

Status of switch blade is<br />

critical<br />

s31SysFanAdded<br />

System fan added<br />

s31SysFanRemoved<br />

System fan removed<br />

s31SysFanOk<br />

Status of system fan is OK<br />

s31SysFanError<br />

Status of system fan is error<br />

s31SysFanCriticalError<br />

Status of system fan is critical<br />

table: BLADE-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7244.1.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1600 INFORMAT<br />

IONAL<br />

1601 INFORMAT<br />

IONAL<br />

1602 INFORMAT<br />

IONAL<br />

1603 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Test trap from blade chassis %s (no<br />

error).<br />

Management blade %d at blade chassis<br />

%s was added.<br />

Management blade %d at blade chassis<br />

%s was removed.<br />

Management blade %d at blade chassis<br />

%s status is ok.<br />

1604 MAJOR Management blade %d at blade chassis<br />

%s status is error.<br />

1605 CRITICAL Management blade %d at blade chassis<br />

%s status is critical.<br />

1606 INFORMAT<br />

IONAL<br />

1607 INFORMAT<br />

IONAL<br />

1608 INFORMAT<br />

IONAL<br />

Server blade %d at blade chassis %s was<br />

added.<br />

Server blade %d at blade chassis %s was<br />

removed.<br />

Server blade %d at blade chassis %s<br />

status is OK.<br />

1609 MAJOR Server blade %d at blade chassis %s status<br />

is error.<br />

1610 CRITICAL Server blade %d at blade chassis %s<br />

status is critical.<br />

1611 INFORMAT<br />

IONAL<br />

1612 INFORMAT<br />

IONAL<br />

1613 INFORMAT<br />

IONAL<br />

Switch blade %d at blade chassis %s was<br />

added.<br />

Switch blade %d at blade chassis %s was<br />

removed.<br />

Switch blade %d at blade chassis %s<br />

status is OK.<br />

1614 MAJOR Switch blade %d at blade chassis %s<br />

status is error.<br />

1615 CRITICAL Switch blade %d at blade chassis %s<br />

status is critical.<br />

1616 INFORMAT<br />

IONAL<br />

1617 INFORMAT<br />

IONAL<br />

1618 INFORMAT<br />

IONAL<br />

System fan %d at blade chassis %s was<br />

added.<br />

System fan %d at blade chassis %s was<br />

removed.<br />

System fan %d at blade chassis %s status<br />

is OK.<br />

1619 MAJOR System fan %d at blade chassis %s status<br />

is error.<br />

1620 CRITICAL System fan %d at blade chassis %s status<br />

is critical.<br />