32<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.11 FSC-SERVERCONTROL2-MIB (sc2.mib)<br />

sc2<strong>Trap</strong>Test<br />

Test trap<br />

<strong>Trap</strong>s from the ServerView agent.<br />

table: FSC-SERVERCONTROL2-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2.2.10.20)<br />

TRAP-TYPE/<br />

Alarm type<br />

sc2<strong>Trap</strong>CommunicationFailure<br />

Communication lost<br />

sc2<strong>Trap</strong>CommunicationEstablished<br />

Communication established<br />

sc2<strong>Trap</strong>ControllerSelftestWarning<br />

Controller selftest warning<br />

sc2<strong>Trap</strong>ControllerSelftestError<br />

Controller selftest error<br />

sc2<strong>Trap</strong>BiosSelftestError<br />

Critical BIOS selftest error<br />

sc2<strong>Trap</strong>FanAdded<br />

Fan added<br />

sc2<strong>Trap</strong>FanRemoved<br />

Fan removed<br />

sc2<strong>Trap</strong>FanOk<br />

Fan OK<br />

sc2<strong>Trap</strong>FanCritical<br />

Fan failure predicted<br />

sc2<strong>Trap</strong>FanFailed<br />

Fan failed<br />

sc2<strong>Trap</strong>RedundantFanFailed<br />

Redundant fan failed<br />

sc2<strong>Trap</strong>TempOk<br />

Temperature normal<br />

sc2<strong>Trap</strong>TempWarning<br />

Temperature warning<br />

sc2<strong>Trap</strong>TempCritical<br />

Temperature critical<br />

sc2<strong>Trap</strong>TempSensorOk<br />

Temperature sensor OK<br />

sc2<strong>Trap</strong>TempSensorBroken<br />

Temperature sensor broken<br />

sc2<strong>Trap</strong>PowerSupplyAdded<br />

Power supply added<br />

sc2<strong>Trap</strong>PowerSupplyRemoved<br />

Power supply removed<br />

Specific<br />

Level of<br />

importance<br />

2000 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Test trap from server %s (no error).<br />

2001 MINOR Communication with the Server<br />

Management controller in cabinet %d of<br />

server %s lost.<br />

2002 INFORMAT<br />

IONAL<br />

Communication with the Server<br />

Management controller in cabinet %d of<br />

server %s established again.<br />

2003 MINOR The Server Management controller in<br />

cabinet %d has detected an minor<br />

problem during selftest of server %s.<br />

2004 CRITICAL The Server Management controller in<br />

cabinet %d of server %s failed.<br />

2005 CRITICAL A critical error happend while BIOS<br />

selftest in cabinet %d of server %s. See<br />

server management message log<br />

(recovery log) for detailed information.<br />

2010 INFORMAT<br />

IONAL<br />

2011 INFORMAT<br />

IONAL<br />

2012 INFORMAT<br />

IONAL<br />

Fan %s was added into cabinet %d of<br />

server %s.<br />

Fan %s was removed from cabinet %d of<br />

server %s.<br />

Fan %s in cabinet %d of server %s is<br />

working again.<br />

2013 MAJOR Fan %s will fail in near future in cabinet<br />

%d of server %s.<br />

2014 CRITICAL Fan %s failed in cabinet %d of server %s.<br />

2015 MAJOR The redundant fan %s failed in cabinet<br />

%d of server %s. System can become<br />

critical if another fan in this group fails.<br />

2020 INFORMAT<br />

IONAL<br />

Temperature at sensor %s in cabinet %d<br />

of server %s is within normal range.<br />

2021 MAJOR Temperature at sensor %s in cabinet %d<br />

of server %s has reached the warning<br />

level.<br />

2022 CRITICAL Temperature at sensor %s in cabinet %d<br />

of server %s has reached the critical<br />

level.<br />

2023 INFORMAT<br />

IONAL<br />

Temperature sensor %s in cabinet %d of<br />

server %s is working again.<br />

2024 MAJOR Temperature sensor %s in cabinet %d of<br />

server %s is broken or not connected.<br />

2030 INFORMAT<br />

IONAL<br />

2031 INFORMAT<br />

IONAL<br />

Power supply %s in cabinet %d at server<br />

%s was added.<br />

Power supply %s in cabinet %d at server<br />

%s was removed.<br />