TRAP-TYPE/<br />

Alarm type<br />

sieScBootRetryCountZero<br />

Boot retry counter zero<br />

sieScMessageLogFull<br />

Message log full<br />

memErrorModulePrefailure<br />

Memory module prefailure<br />

memErrorModuleFailing<br />

Memory module failing<br />

memErrorModuleReplaced<br />

Memory module replaced<br />

sniScPowerSupplyRedundanc<br />

yLost<br />

Power supply redundancy lost<br />

sieScMessageLogWarning<br />

Message log warning<br />

666 MAJOR Boot retry counter is zero on server %s.<br />

On next critical error shutdown the server<br />

will no longer try to reboot. System will<br />

run diagnostic system or switch off.<br />

667 MINOR The System Event Log on server %s in<br />

cabinet %d is full. No more messages can<br />

be logged. Please clear unneeded log<br />

entries as soon as possible!<br />

668 MAJOR Memory module failure is predicted for<br />

module %d in cabinet %d of server %s.<br />

669 MAJOR Memory module %d in cabinet %d of<br />

server %s is failing. Too many errors<br />

have occured.<br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

670 MAJOR Memory module module %d in cabinet<br />

%d of server %s had failed<br />

and was replaced by a hot-spare module.<br />

671 MINOR Power supply redundancy in cabinet %d<br />

at server %s lost. System will become<br />

critical if a power supply fails.<br />

672 MINOR The System Event Log for cabinet %d at<br />

server %s has exceeded %d%% of its<br />

capacity.<br />

Remarks<br />

Operations were<br />

performed for the<br />

amount of retry<br />

counters set.<br />

Set the retry counters<br />

again.<br />

Clear the unnecessary<br />

System Event Log<br />

using the<br />

maintenance tools<br />

attached to the<br />

hardware.<br />

This predicts a<br />

memory error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Warning predicting a<br />

memory error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Memory error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Power supply unit<br />

error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

This predicts a<br />

System Event Log.<br />

Clear the unnecessary<br />

System Event Log<br />

using the<br />

maintenance tools<br />

attached to the<br />

hardware.<br />