13.08.2012 Views

Serverview Trap List

Serverview Trap List

Serverview Trap List

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

22<br />

B <strong>Trap</strong> <strong>List</strong><br />

sniScShutdownCancelled<br />

Shutdown cancelled<br />

sniScCpuSpeedChanged<br />

CPU speed changed<br />

sieScPowerOn<br />

Power on<br />

sieScNoBootCpu<br />

No boot cpu<br />

sieScPostError<br />

Post error<br />

TRAP-TYPE/<br />

Alarm type<br />

sieScSetupEntered<br />

Setup entered<br />

sieScBootError<br />

Boot error<br />

sieScBootWatchdogExpired<br />

Boot watchdog expired<br />

sieScSoftwareWatchdogExpir<br />

ed<br />

Software watchdog expired<br />

sieScUserAuthenticationFailur<br />

e<br />

User authentication failure<br />

sieScDiagnosticBoot<br />

Diagnostic boot<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

655 INFORMAT<br />

IONAL<br />

656 INFORMAT<br />

IONAL<br />

657 INFORMAT<br />

IONAL<br />

658 INFORMAT<br />

IONAL<br />

659 INFORMAT<br />

IONAL<br />

660 INFORMAT<br />

IONAL<br />

661 INFORMAT<br />

IONAL<br />

662 INFORMAT<br />

IONAL<br />

663 INFORMAT<br />

IONAL<br />

Shutdown at server %s cancelled by the<br />

user.<br />

CPU speed at server %s changed to %d<br />

percent of its maximum speed. The CPU<br />

speed can be changed by the server<br />

management because of temperature<br />

problems.<br />

The reason %s causes a power on at<br />

server %s.<br />

System boot of the server %s failed,<br />

because no valid boot cpu available.<br />

The reason %s causes a power on at<br />

server %s.<br />

This is an operation.<br />

The speed of the CPU<br />

is lowered because of<br />

the high temperature<br />

of the CPU.<br />

Check CPU<br />

temperature.<br />

A broken fan may be<br />

causing the<br />

temperature of the<br />

CPU to rise.<br />

This message appears<br />

when the power<br />

supply is turned on.<br />

Check the system.<br />

A CPU error may<br />

have occurred.<br />

IF this occurs<br />

frequently, refer to<br />

"Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

The bios setup is entered at server %s. Setup operations have<br />

been performed by<br />

the operator.<br />

No bootable operation system found at<br />

server %s.<br />

Check the system.<br />

Boot watchdog of server %s expired. Operations were<br />

performed for the<br />

amount of retry<br />

counters set.<br />

Set the retry counters<br />

again.<br />

Software watchdog of server %s expired. Operations were<br />

performed for the<br />

amount of retry<br />

counters set.<br />

Set the retry counters<br />

again.<br />

664 MAJOR User authentication failure detected at<br />

server %s, interface %d, performing<br />

protocol %s.<br />

665 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Server %s is performing a diagnostic<br />

boot.<br />

Remarks<br />

Check the<br />

authentication<br />

operations.<br />

Diagnostic operations<br />

are performed by the<br />

operator.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!