Serverview Trap List
Serverview Trap List Serverview Trap List
20 B Trap List TRAP-TYPE/ Alarm type correctableMemErrorBank Correctable memory error #1 uncorrectableMemErrorBank Uncorrectable memory error #1 correctableMemErrorModule Correctable memory error #2 uncorrectableMemErrorModul e Uncorrectable memory error #2 correctableMemError Correctable memory error #3 uncorrectableMemError Uncorrectable memory error #3 powerOffTimeReached Power off time reached table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises.231.2.10.2) Specific Level of importance 639 INFORMAT IONAL Correctable memory error at bank %d in cabinet %d of server %s. 640 CRITICAL Uncorrectable memory error at bank %d in cabinet %d of server %s. 641 INFORMAT IONAL Correctable memory error at module %d in cabinet %d of server %s. 642 CRITICAL Uncorrectable memory error at module %d in cabinet %d of server %s. 643 INFORMAT IONAL Correctable memory error in cabinet %d of server %s. 644 CRITICAL Uncorrectable memory error in cabinet %d of server %s. 645 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) The power-off time is reached in cabinet %d on server %s! System shutdown in %d minutes. Remarks An SBE (memory single bit) has occurred. This error has no effect as ECC memory is being used. An MBE (memory multibit error) has occurred. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. An SBE (memory single bit error) has occurred. This error has no effect as ECC memory is being used. An MBE (memory multibit error) has occurred. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. An SBE (memory single bit error) has occurred. This error has no effect as ECC memory is being used. An MBE (memory multibit error) has occurred. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. Shut down is performed due to an order by the ServerView console or a power off scheduled in ServerView.
TRAP-TYPE/ Alarm type frontDoorStatusChanged Front door status changed housingOpenStatusChanged Housing open status changed sniScRedundantFanFailed Redundant fan failed sniScRedundantPowerSupply Failed Redundant power supply failed sniScVoltageOk Voltage OK sniScVoltageTooLow Voltage too low sniScVoltageTooHigh Voltage too high sniScFanAdded Fan added sniScFanRemoved Fan removed 646 INFORMAT IONAL 647 INFORMAT IONAL B.3 SNI-SERVER-CONTROL-MIB (sc.mib) table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises.231.2.10.2) Specific Level of importance The front door status of cabinet %d on server %s has changed. The housing open status of cabinet %d on server %s has changed. 648 MAJOR The redundant fan %d failed in cabinet %d of server %s. System can become critical if another fan in this group fails. 649 MAJOR Redundant power supply %d in cabinet %d at server %s failed. System can become critical if another power supply fails. 650 INFORMAT IONAL Power supply voltage %d (%s) in cabinet %d at server %s is within normal range again. 651 CRITICAL Power supply voltage %d (%s) in cabinet %d at server %s is too low. 652 CRITICAL Power supply voltage %d (%s) in cabinet %d at server %s is too high. 653 INFORMAT IONAL 654 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) The fan %d was added into cabinet %d of server %s. The fan %d was removed from cabinet %d of server %s. Remarks The door has been opened or closed by the operator. The cover of the server has been opened or closed by the operator. A redundant fan failure has occurred. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. A redundant power supply failure has occurred. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. The server voltage has recovered. There is no problem. A problem may have occurred with the power supply unit, AC power supply or the base board etc. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. A problem may have occurred with the power supply unit, AC power supply or the base board etc. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. The fan was added by the operator. The fan was removed by the operator. 21
- Page 1: About this manual A Trap List Overv
- Page 4 and 5: 4 B.37 EM4513-MIB (unicorn-trap.mib
- Page 6 and 7: 6 A Trap List Overview A.3 Screen d
- Page 8 and 9: 8 A Trap List Overview ● MIB file
- Page 10 and 11: 10 B Trap List TRAP-TYPE/ Alarm typ
- Page 12 and 13: 12 B Trap List TRAP-TYPE/ Alarm typ
- Page 14 and 15: 14 B Trap List TRAP-TYPE/ Alarm typ
- Page 16 and 17: 16 B Trap List B.3 SNI-SERVER-CONTR
- Page 18 and 19: 18 B Trap List TRAP-TYPE/ Alarm typ
- Page 22 and 23: 22 B Trap List sniScShutdownCancell
- Page 24 and 25: 24 B Trap List TRAP-TYPE/ Alarm typ
- Page 26 and 27: 26 B Trap List B.5 SNI-HD-MIB (hd.m
- Page 28 and 29: 28 B Trap List TRAP-TYPE/ Alarm typ
- Page 30 and 31: 30 B Trap List TRAP-TYPE/ Alarm typ
- Page 32 and 33: 32 B Trap List B.11 FSC-SERVERCONTR
- Page 34 and 35: 34 B Trap List table: FSC-SERVERCON
- Page 36 and 37: 36 B Trap List TRAP-TYPE/ Alarm typ
- Page 38 and 39: 38 B Trap List TRAP-TYPE/ Alarm typ
- Page 40 and 41: 40 B Trap List TRAP-TYPE/ Alarm typ
- Page 42 and 43: 42 B Trap List TRAP-TYPE/ Alarm typ
- Page 44 and 45: 44 B Trap List TRAP-TYPE/ Alarm typ
- Page 46 and 47: 46 B Trap List TRAP-TYPE/ Alarm typ
- Page 48 and 49: 48 B Trap List TRAP-TYPE/ Alarm typ
- Page 50 and 51: 50 B Trap List TRAP-TYPE/ Alarm typ
- Page 52 and 53: 52 B Trap List B.19 PROMISE-UNIFIED
- Page 54 and 55: 54 B Trap List TRAP-TYPE/ Alarm typ
- Page 56 and 57: 56 B Trap List B.21 UPSMAN (Upsman.
- Page 58 and 59: 58 B Trap List B.23 PowerNet-MIB (p
- Page 60 and 61: 60 B Trap List TRAP-TYPE/ Alarm typ
- Page 62 and 63: 62 B Trap List TRAP-TYPE/ Alarm typ
- Page 64 and 65: 64 B Trap List TRAP-TYPE/ Alarm typ
- Page 66 and 67: 66 B Trap List TRAP-TYPE/ Alarm typ
- Page 68 and 69: 68 B Trap List TRAP-TYPE/ Alarm typ
TRAP-TYPE/<br />
Alarm type<br />
frontDoorStatusChanged<br />
Front door status changed<br />
housingOpenStatusChanged<br />
Housing open status changed<br />
sniScRedundantFanFailed<br />
Redundant fan failed<br />
sniScRedundantPowerSupply<br />
Failed<br />
Redundant power supply<br />
failed<br />
sniScVoltageOk<br />
Voltage OK<br />
sniScVoltageTooLow<br />
Voltage too low<br />
sniScVoltageTooHigh<br />
Voltage too high<br />
sniScFanAdded<br />
Fan added<br />
sniScFanRemoved<br />
Fan removed<br />
646 INFORMAT<br />
IONAL<br />
647 INFORMAT<br />
IONAL<br />
B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />
table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />
Specific<br />
Level of<br />
importance<br />
The front door status of cabinet %d on<br />
server %s has changed.<br />
The housing open status of cabinet %d on<br />
server %s has changed.<br />
648 MAJOR The redundant fan %d failed in cabinet<br />
%d of server %s. System can become<br />
critical if another fan in this group fails.<br />
649 MAJOR Redundant power supply %d in cabinet<br />
%d at server %s failed. System can<br />
become critical if another power supply<br />
fails.<br />
650 INFORMAT<br />
IONAL<br />
Power supply voltage %d (%s) in cabinet<br />
%d at server %s is within normal range<br />
again.<br />
651 CRITICAL Power supply voltage %d (%s) in cabinet<br />
%d at server %s is too low.<br />
652 CRITICAL Power supply voltage %d (%s) in cabinet<br />
%d at server %s is too high.<br />
653 INFORMAT<br />
IONAL<br />
654 INFORMAT<br />
IONAL<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
The fan %d was added into cabinet %d of<br />
server %s.<br />
The fan %d was removed from cabinet<br />
%d of server %s.<br />
Remarks<br />
The door has been<br />
opened or closed by<br />
the operator.<br />
The cover of the<br />
server has been<br />
opened or closed by<br />
the operator.<br />
A redundant fan<br />
failure has occurred.<br />
Refer to "Contact<br />
Information" in<br />
"Read me First", and<br />
contact your<br />
maintenance<br />
engineer.<br />
A redundant power<br />
supply failure has<br />
occurred.<br />
Refer to "Contact<br />
Information" in<br />
"Read me First", and<br />
contact your<br />
maintenance<br />
engineer.<br />
The server voltage<br />
has recovered.<br />
There is no problem.<br />
A problem may have<br />
occurred with the<br />
power supply unit,<br />
AC power supply or<br />
the base board etc.<br />
Refer to "Contact<br />
Information" in<br />
"Read me First", and<br />
contact your<br />
maintenance<br />
engineer.<br />
A problem may have<br />
occurred with the<br />
power supply unit,<br />
AC power supply or<br />
the base board etc.<br />
Refer to "Contact<br />
Information" in<br />
"Read me First", and<br />
contact your<br />
maintenance<br />
engineer.<br />
The fan was added by<br />
the operator.<br />
The fan was removed<br />
by the operator.<br />
21