13.08.2012 Views

Serverview Trap List

Serverview Trap List

Serverview Trap List

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TRAP-TYPE/<br />

Alarm type<br />

svCommunicationFailure<br />

Communication lost<br />

scbUnconfiguredUPSDetected<br />

UPS not configured<br />

scbUPSNotdetected<br />

UPS not detected<br />

scbUnconfiguredBBUDetected<br />

BBU not configured<br />

scbBBUNotdetected<br />

BBU not detected<br />

notEnoughCabinets<br />

SE's missing<br />

tooManyCabinets<br />

Too many SE's<br />

cabinetSwitchedOff<br />

Cabinet switched off<br />

cabinetSwitchedOn<br />

Cabinet switched on<br />

internalError<br />

Internal error<br />

serverShutdown<br />

Server shutdown<br />

610 MINOR Communication with the Server<br />

Management controller in cabinet %d of<br />

server %s lost.<br />

611 INFORMAT<br />

IONAL<br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

UPS detected by server %s, but no UPS<br />

is configured.<br />

612 MAJOR A UPS is configured but no UPS detected<br />

by server %s.<br />

613 INFORMAT<br />

IONAL<br />

614 INFORMAT<br />

IONAL<br />

BBU detected by server %s, but no BBU is<br />

configured.<br />

A BBU is configured but no BBU is<br />

detected by server %s.<br />

615 MAJOR The actual number of storage extensions<br />

at server %s is lower than the configured.<br />

616 MINOR The actual number of storage extensions<br />

at server %s is higher than the<br />

configured.<br />

617 INFORMAT<br />

IONAL<br />

618 INFORMAT<br />

IONAL<br />

620 INFORMAT<br />

IONAL<br />

621 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Cabinet %d was switched off because of<br />

%s (server %s).<br />

Cabinet %d was switched on because of<br />

%s (server %s).<br />

Internal error #%d in server management<br />

controller software. (module %s at server<br />

%s).<br />

The reason %s causes a shutdown at<br />

server %s.<br />

Remarks<br />

If recovered in event<br />

ID:10636 there is no<br />

problem.<br />

If not restored, refer<br />

to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

It is possible that<br />

there is an error in the<br />

settings. Recheck the<br />

settings.<br />

If there is no error in<br />

the settings it is<br />

possible that a UPS<br />

error occurred. Refer<br />

to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

There is an error in<br />

the configuration of<br />

the external memory<br />

device. Recheck this.<br />

Server%s has turned<br />

off.<br />

Server%s has turned<br />

on.<br />

This is a software<br />

error. Specify the<br />

name of the module<br />

and, refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Shutdown at the<br />

server is performed<br />

by ordering<br />

shutdown.<br />

17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!