Serverview Trap List

Serverview Trap List Serverview Trap List

13.08.2012 Views

16 B Trap List B.3 SNI-SERVER-CONTROL-MIB (sc.mib) Traps from the ServerView agent or RSB. TRAP-TYPE/ Alarm type testTrap Test trap fanError Fan failed tempOk Temperature normal tempWarn Temperature warning tempCritical Temperature critical trapOnBattery AC failed, on battery trapOnMains AC OK selftestWarning Controller selftest warning selftestError Controller selftest error table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises.231.2.10.2) Specific Level of importance 600 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) Test trap from server %s (no error). No error. 601 CRITICAL Fan %d failed in cabinet %d of server %s. 602 INFORMAT IONAL Temperature at sensor %d in cabinet %d of server %s is within normal range. 603 MAJOR Temperature at sensor %d in cabinet %d of server %s has reached the warning level. 604 CRITICAL Temperature at sensor %d in cabinet %d of server %s has reached the critical level. 606 CRITICAL AC failure. Cabinet %d is running on battery power since %d seconds. In %d minutes server %s will shutdown. 607 INFORMAT IONAL Mains returned after power failure in cabinet %d at server %s. 608 MINOR The Server Management controller in cabinet %d has detected an minor problem during selftest of server %s. 609 CRITICAL The Server Management controller in cabinet %d of server %s failed. Remarks A fan error occurred. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. The internal temperature of the server is within the normal range. No error. A device temperature error occurred. Check the room temperature. If room temperature is normal check whether the fan has failed. Other errors in hardware are possible. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. Running on UPS battery power. Check that UPS power cables are not unplugged and there has been no power interruption. Stopped running on the UPS battery. No problem. If multiple messages are detected, it is possible that the Server Management controller has failed. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer.

TRAP-TYPE/ Alarm type svCommunicationFailure Communication lost scbUnconfiguredUPSDetected UPS not configured scbUPSNotdetected UPS not detected scbUnconfiguredBBUDetected BBU not configured scbBBUNotdetected BBU not detected notEnoughCabinets SE's missing tooManyCabinets Too many SE's cabinetSwitchedOff Cabinet switched off cabinetSwitchedOn Cabinet switched on internalError Internal error serverShutdown Server shutdown 610 MINOR Communication with the Server Management controller in cabinet %d of server %s lost. 611 INFORMAT IONAL B.3 SNI-SERVER-CONTROL-MIB (sc.mib) table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises.231.2.10.2) Specific Level of importance UPS detected by server %s, but no UPS is configured. 612 MAJOR A UPS is configured but no UPS detected by server %s. 613 INFORMAT IONAL 614 INFORMAT IONAL BBU detected by server %s, but no BBU is configured. A BBU is configured but no BBU is detected by server %s. 615 MAJOR The actual number of storage extensions at server %s is lower than the configured. 616 MINOR The actual number of storage extensions at server %s is higher than the configured. 617 INFORMAT IONAL 618 INFORMAT IONAL 620 INFORMAT IONAL 621 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) Cabinet %d was switched off because of %s (server %s). Cabinet %d was switched on because of %s (server %s). Internal error #%d in server management controller software. (module %s at server %s). The reason %s causes a shutdown at server %s. Remarks If recovered in event ID:10636 there is no problem. If not restored, refer to "Contact Information" in "Read me First", and contact your maintenance engineer. It is possible that there is an error in the settings. Recheck the settings. If there is no error in the settings it is possible that a UPS error occurred. Refer to "Contact Information" in "Read me First", and contact your maintenance engineer. There is an error in the configuration of the external memory device. Recheck this. Server%s has turned off. Server%s has turned on. This is a software error. Specify the name of the module and, refer to "Contact Information" in "Read me First", and contact your maintenance engineer. Shutdown at the server is performed by ordering shutdown. 17

16<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

<strong>Trap</strong>s from the ServerView agent or RSB.<br />

TRAP-TYPE/<br />

Alarm type<br />

test<strong>Trap</strong><br />

Test trap<br />

fanError<br />

Fan failed<br />

tempOk<br />

Temperature normal<br />

tempWarn<br />

Temperature warning<br />

tempCritical<br />

Temperature critical<br />

trapOnBattery<br />

AC failed, on battery<br />

trapOnMains<br />

AC OK<br />

selftestWarning<br />

Controller selftest warning<br />

selftestError<br />

Controller selftest error<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

600 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Test trap from server %s (no error). No error.<br />

601 CRITICAL Fan %d failed in cabinet %d of server<br />

%s.<br />

602 INFORMAT<br />

IONAL<br />

Temperature at sensor %d in cabinet %d<br />

of server %s is within normal range.<br />

603 MAJOR Temperature at sensor %d in cabinet %d<br />

of server %s has reached the warning<br />

level.<br />

604 CRITICAL Temperature at sensor %d in cabinet %d<br />

of server %s has reached the critical level.<br />

606 CRITICAL AC failure. Cabinet %d is running on<br />

battery power since %d seconds. In %d<br />

minutes server %s will shutdown.<br />

607 INFORMAT<br />

IONAL<br />

Mains returned after power failure in cabinet<br />

%d at server %s.<br />

608 MINOR The Server Management controller in<br />

cabinet %d has detected an minor<br />

problem during selftest of server %s.<br />

609 CRITICAL The Server Management controller in<br />

cabinet %d of server %s failed.<br />

Remarks<br />

A fan error occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

The internal<br />

temperature of the<br />

server is within the<br />

normal range. No<br />

error.<br />

A device temperature<br />

error occurred. Check<br />

the room temperature.<br />

If room temperature is<br />

normal check whether<br />

the fan has failed.<br />

Other errors in<br />

hardware are possible.<br />

Refer to "Contact<br />

Information" in "Read<br />

me First", and contact<br />

your maintenance<br />

engineer.<br />

Running on UPS<br />

battery power.<br />

Check that UPS<br />

power cables are not<br />

unplugged and there<br />

has been no power<br />

interruption.<br />

Stopped running on<br />

the UPS battery.<br />

No problem. If<br />

multiple messages are<br />

detected, it is possible<br />

that the Server<br />

Management<br />

controller has failed.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.