Serverview Trap List
Serverview Trap List Serverview Trap List
14 B Trap List TRAP-TYPE/ Alarm type mylexInitializationStarted Initialization started mylexInitializationDone Initialization done mylexInitializationCanceled Initialization canceled mylexInitializationFailed Initialization failed mylexSystemDriveCreated System drive created mylexSystemDriveDeleted System drive deleted mylexRaidExpansionStarted RAID expansion started mylexRaidExpansionDone RAID expansion done mylexRaidExpansionFailed RAID expansion failed mylexSystemDriveBadBlock Bad block mylexSystemDriveSizeChang ed System drive size changed mylexRaidTypeChanged RAID type changed mylexPhysicalDeviceHotspare Physical device hotspare mylexPhysicalDeviceHardErr or Physical device hard error mylexPhysicalDeviceSoftErro r Physical device soft error mylexPhysicalDeviceParityEr ror Physical device parity error mylexPhysicalDeviceMiscErr or Physical device miscellaneous error table: SNI-MYLEX-MIB Trap (ENTERPRISE : enterprises.231.2.10.2) Specific Level of importance 229 INFORMAT IONAL 230 INFORMAT IONAL 231 INFORMAT IONAL Initialization of system drive %d started at disk array adapter in slot %d at server %s. Initialization of system drive %d successfully finished at disk array adapter in slot %d at server %s. Initialization of system drive %d canceled at disk array adapter in slot %d at server %s. 232 MAJOR Initialization of system drive %d failed at disk array adapter in slot %d at server %s. 233 INFORMAT IONAL 234 INFORMAT IONAL 235 INFORMAT IONAL 236 INFORMAT IONAL New system drive %d created at disk array adapter in slot %d at server %s. System drive %d deleted at disk array adapter in slot %d at server %s. RAID capacity expansion on system drive %d started at disk array adapter in slot %d at server %s. RAID capacity expansion on system drive %d successfully finished at disk array adapter in slot %d at server %s. 237 MAJOR RAID capacity expansion failed on system drive %d at disk array adapter in slot %d at server %s. 238 MINOR Bad block(s) detected on system drive %d at disk array adapter in slot %d at server %s. 239 INFORMAT IONAL 240 INFORMAT IONAL 250 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) Size of system drive %d was changed at disk array adapter in slot %d at server %s. RAID type of system drive %d was changed at disk array adapter in slot %d at server %s. Physical device %d on channel %d at disk array adapter in slot %d is now HOTSPARE (Server %s). 251 MINOR Hard error occurred at physical device %d on channel %d at disk array adapter in slot %d (Server %s). 252 MINOR Soft error occurred at physical device %d on channel %d at disk array adapter in slot %d (Server %s). 253 MINOR Parity error occurred at physical device %d on channel %d at disk array adapter in slot %d (Server %s). 254 MINOR Miscellaneous error occurred at physical device %d on channel %d at disk array adapter in slot %d (Server %s). Remarks
TRAP-TYPE/ Alarm type mylexPhysicalDevicePrefailur e Physical device prefailure mylexPhysicalDeviceUnconfi gured Physical device unconfigured mylexPhysicalDeviceAdded Physical device added mylexPhysicalDeviceRemove d Physical device removed mylexWriteBackError2 Write back error mylexGamDriverMissing Missing GAM driver mylexGamDriverIncorrectVer sion Incorrect GAM driver version mylexSMARTFailurePredicte d SMART predicted disk failure mylexSMARTConfigurationC hanged SMART configuration changed mylexBBUFound BBU found mylexBBUPowerLow BBU power low mylexBBUPowerOK BBU power OK table: SNI-MYLEX-MIB Trap (ENTERPRISE : enterprises.231.2.10.2) Specific Level of importance 255 MAJOR Prefailure alert from physical device %d on channel %d at disk array adapter in slot %d (Server %s). Device will fail in near future! 256 MAJOR Physical device %d on channel %d at disk array adapter in slot %d is unconfigured (Server %s). 257 MAJOR Physical device %d on channel %d at disk array adapter in slot %d was added (Server %s). 258 MAJOR Physical device %d on channel %d at disk array adapter in slot %d was removed (Server %s). 260 MAJOR Controller cache write back error at disk array adapter in slot %d (Server %s). 261 MINOR GAM driver is either not installed or has failed to start; required version: %s (server %s). 262 MINOR Incorrect version of GAM driver installed (%s); required version: %s (server %s). 270 CRITICAL SMART predicts failure for disk %d on channel %d at disk array adapter in slot %d (Server %s). 271 INFORMAT IONAL 275 INFORMAT IONAL SMART configuration has been changed for disk %d on channel %d at disk array adapter in slot %d (Server %s). A Battery Backup Unit was found on SCSI controller in slot %d (Server %s). 276 CRITICAL The Battery Backup Unit power on SCSI controller in slot %d is low (Server %s). If this messages happens without power failure, replace the BBU. 277 INFORMAT IONAL Detailed Messages (%d: optional number %s: system variable) The Battery Backup Unit power on SCSI controller in slot %d is OK (Server %s). B.2 SNI-MYLEX-MIB (mylex.mib) Remarks 15
- Page 1: About this manual A Trap List Overv
- Page 4 and 5: 4 B.37 EM4513-MIB (unicorn-trap.mib
- Page 6 and 7: 6 A Trap List Overview A.3 Screen d
- Page 8 and 9: 8 A Trap List Overview ● MIB file
- Page 10 and 11: 10 B Trap List TRAP-TYPE/ Alarm typ
- Page 12 and 13: 12 B Trap List TRAP-TYPE/ Alarm typ
- Page 16 and 17: 16 B Trap List B.3 SNI-SERVER-CONTR
- Page 18 and 19: 18 B Trap List TRAP-TYPE/ Alarm typ
- Page 20 and 21: 20 B Trap List TRAP-TYPE/ Alarm typ
- Page 22 and 23: 22 B Trap List sniScShutdownCancell
- Page 24 and 25: 24 B Trap List TRAP-TYPE/ Alarm typ
- Page 26 and 27: 26 B Trap List B.5 SNI-HD-MIB (hd.m
- Page 28 and 29: 28 B Trap List TRAP-TYPE/ Alarm typ
- Page 30 and 31: 30 B Trap List TRAP-TYPE/ Alarm typ
- Page 32 and 33: 32 B Trap List B.11 FSC-SERVERCONTR
- Page 34 and 35: 34 B Trap List table: FSC-SERVERCON
- Page 36 and 37: 36 B Trap List TRAP-TYPE/ Alarm typ
- Page 38 and 39: 38 B Trap List TRAP-TYPE/ Alarm typ
- Page 40 and 41: 40 B Trap List TRAP-TYPE/ Alarm typ
- Page 42 and 43: 42 B Trap List TRAP-TYPE/ Alarm typ
- Page 44 and 45: 44 B Trap List TRAP-TYPE/ Alarm typ
- Page 46 and 47: 46 B Trap List TRAP-TYPE/ Alarm typ
- Page 48 and 49: 48 B Trap List TRAP-TYPE/ Alarm typ
- Page 50 and 51: 50 B Trap List TRAP-TYPE/ Alarm typ
- Page 52 and 53: 52 B Trap List B.19 PROMISE-UNIFIED
- Page 54 and 55: 54 B Trap List TRAP-TYPE/ Alarm typ
- Page 56 and 57: 56 B Trap List B.21 UPSMAN (Upsman.
- Page 58 and 59: 58 B Trap List B.23 PowerNet-MIB (p
- Page 60 and 61: 60 B Trap List TRAP-TYPE/ Alarm typ
- Page 62 and 63: 62 B Trap List TRAP-TYPE/ Alarm typ
TRAP-TYPE/<br />
Alarm type<br />
mylexPhysicalDevicePrefailur<br />
e<br />
Physical device prefailure<br />
mylexPhysicalDeviceUnconfi<br />
gured<br />
Physical device unconfigured<br />
mylexPhysicalDeviceAdded<br />
Physical device added<br />
mylexPhysicalDeviceRemove<br />
d<br />
Physical device removed<br />
mylexWriteBackError2<br />
Write back error<br />
mylexGamDriverMissing<br />
Missing GAM driver<br />
mylexGamDriverIncorrectVer<br />
sion<br />
Incorrect GAM driver version<br />
mylexSMARTFailurePredicte<br />
d<br />
SMART predicted disk failure<br />
mylexSMARTConfigurationC<br />
hanged<br />
SMART configuration<br />
changed<br />
mylexBBUFound<br />
BBU found<br />
mylexBBUPowerLow<br />
BBU power low<br />
mylexBBUPowerOK<br />
BBU power OK<br />
table: SNI-MYLEX-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />
Specific<br />
Level of<br />
importance<br />
255 MAJOR Prefailure alert from physical device %d<br />
on channel %d at disk array adapter in<br />
slot %d (Server %s). Device will fail in<br />
near future!<br />
256 MAJOR Physical device %d on channel %d at<br />
disk array adapter in slot %d is<br />
unconfigured (Server %s).<br />
257 MAJOR Physical device %d on channel %d at<br />
disk array adapter in slot %d was added<br />
(Server %s).<br />
258 MAJOR Physical device %d on channel %d at<br />
disk array adapter in slot %d was<br />
removed (Server %s).<br />
260 MAJOR Controller cache write back error at disk<br />
array adapter in slot %d (Server %s).<br />
261 MINOR GAM driver is either not installed or has<br />
failed to start; required version: %s<br />
(server %s).<br />
262 MINOR Incorrect version of GAM driver installed<br />
(%s); required version: %s (server %s).<br />
270 CRITICAL SMART predicts failure for disk %d on<br />
channel %d at disk array adapter in slot<br />
%d (Server %s).<br />
271 INFORMAT<br />
IONAL<br />
275 INFORMAT<br />
IONAL<br />
SMART configuration has been changed<br />
for disk %d on channel %d at disk array<br />
adapter in slot %d (Server %s).<br />
A Battery Backup Unit was found on<br />
SCSI controller in slot %d (Server %s).<br />
276 CRITICAL The Battery Backup Unit power on SCSI<br />
controller in slot %d is low (Server %s).<br />
If this messages happens without power<br />
failure, replace the BBU.<br />
277 INFORMAT<br />
IONAL<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
The Battery Backup Unit power on SCSI<br />
controller in slot %d is OK (Server %s).<br />
B.2 SNI-MYLEX-MIB (mylex.mib)<br />
Remarks<br />
15