Serverview Trap List
Serverview Trap List
Serverview Trap List
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
14<br />
B <strong>Trap</strong> <strong>List</strong><br />
TRAP-TYPE/<br />
Alarm type<br />
mylexInitializationStarted<br />
Initialization started<br />
mylexInitializationDone<br />
Initialization done<br />
mylexInitializationCanceled<br />
Initialization canceled<br />
mylexInitializationFailed<br />
Initialization failed<br />
mylexSystemDriveCreated<br />
System drive created<br />
mylexSystemDriveDeleted<br />
System drive deleted<br />
mylexRaidExpansionStarted<br />
RAID expansion started<br />
mylexRaidExpansionDone<br />
RAID expansion done<br />
mylexRaidExpansionFailed<br />
RAID expansion failed<br />
mylexSystemDriveBadBlock<br />
Bad block<br />
mylexSystemDriveSizeChang<br />
ed<br />
System drive size changed<br />
mylexRaidTypeChanged<br />
RAID type changed<br />
mylexPhysicalDeviceHotspare<br />
Physical device hotspare<br />
mylexPhysicalDeviceHardErr<br />
or<br />
Physical device hard error<br />
mylexPhysicalDeviceSoftErro<br />
r<br />
Physical device soft error<br />
mylexPhysicalDeviceParityEr<br />
ror<br />
Physical device parity error<br />
mylexPhysicalDeviceMiscErr<br />
or<br />
Physical device miscellaneous<br />
error<br />
table: SNI-MYLEX-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />
Specific<br />
Level of<br />
importance<br />
229 INFORMAT<br />
IONAL<br />
230 INFORMAT<br />
IONAL<br />
231 INFORMAT<br />
IONAL<br />
Initialization of system drive %d started<br />
at disk array adapter in slot %d at server<br />
%s.<br />
Initialization of system drive %d<br />
successfully finished at disk array adapter<br />
in slot %d at server %s.<br />
Initialization of system drive %d<br />
canceled at disk array adapter in slot %d<br />
at server %s.<br />
232 MAJOR Initialization of system drive %d failed at<br />
disk array adapter in slot %d at server<br />
%s.<br />
233 INFORMAT<br />
IONAL<br />
234 INFORMAT<br />
IONAL<br />
235 INFORMAT<br />
IONAL<br />
236 INFORMAT<br />
IONAL<br />
New system drive %d created at disk<br />
array adapter in slot %d at server %s.<br />
System drive %d deleted at disk array<br />
adapter in slot %d at server %s.<br />
RAID capacity expansion on system<br />
drive %d started at disk array adapter in<br />
slot %d at server %s.<br />
RAID capacity expansion on system<br />
drive %d successfully finished at disk<br />
array adapter in slot %d at server %s.<br />
237 MAJOR RAID capacity expansion failed on<br />
system drive %d at disk array adapter in<br />
slot %d at server %s.<br />
238 MINOR Bad block(s) detected on system drive<br />
%d at disk array adapter in slot %d at<br />
server %s.<br />
239 INFORMAT<br />
IONAL<br />
240 INFORMAT<br />
IONAL<br />
250 INFORMAT<br />
IONAL<br />
Detailed Messages<br />
(%d: optional number %s: system<br />
variable)<br />
Size of system drive %d was changed at<br />
disk array adapter in slot %d at server<br />
%s.<br />
RAID type of system drive %d was<br />
changed at disk array adapter in slot %d<br />
at server %s.<br />
Physical device %d on channel %d at<br />
disk array adapter in slot %d is now<br />
HOTSPARE (Server %s).<br />
251 MINOR Hard error occurred at physical device<br />
%d on channel %d at disk array adapter<br />
in slot %d (Server %s).<br />
252 MINOR Soft error occurred at physical device %d<br />
on channel %d at disk array adapter in<br />
slot %d (Server %s).<br />
253 MINOR Parity error occurred at physical device<br />
%d on channel %d at disk array adapter<br />
in slot %d (Server %s).<br />
254 MINOR Miscellaneous error occurred at physical<br />
device %d on channel %d at disk array<br />
adapter in slot %d (Server %s).<br />
Remarks