13.08.2012 Views

Serverview Trap List

Serverview Trap List

Serverview Trap List

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

About this manual<br />

A <strong>Trap</strong> <strong>List</strong> Overview<br />

This describes how to read the trap list table and the screen display examples.<br />

B <strong>Trap</strong> <strong>List</strong><br />

The trap list is described according to its various classifications.<br />

■ Trademarks<br />

ServerView V3.6 <strong>Trap</strong> <strong>List</strong><br />

Microsoft, Windows, MS, Windows Server are registered trademarks of the Microsoft Corporation in the USA and other<br />

countries.<br />

Intel and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the USA and other<br />

countries.<br />

All other hardware and software names used are trademarks or registered trademarks of their respective manufacturers.<br />

Other product names are copyrights of their respective manufacturers.<br />

All Rights Reserved, Copyright © FUJITSU LIMITED 2005<br />

1


Contents<br />

A <strong>Trap</strong> <strong>List</strong> Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />

A.1 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5<br />

A.2 How to read the trap list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5<br />

A.3 Screen display examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6<br />

B <strong>Trap</strong> <strong>List</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

B.1 SNI-TRAP-MIB (trap.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

B.2 SNI-MYLEX-MIB (mylex.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . .16<br />

B.4 SNI-SERVERVIEW-MIB (serverview.mib) . . . . . . . . . . . . . . . . . . . . . . . . . .25<br />

B.5 SNI-HD-MIB (hd.mib ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26<br />

B.6 SNI-NT-CLUSTER-MIB (ntcluster.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . .26<br />

B.7 PCI-HOTPLUG-MIB (pcihotplug.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29<br />

B.8 SERVERVIEW-STATUS-MIB (status.mib) . . . . . . . . . . . . . . . . . . . . . . . . . .29<br />

B.9 SIEMENS-MULTIPATH-MIB (mp.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29<br />

B.10 SERVERVIEW-DUPLEXDATAMANAGER-MIB (ddm.mib) . . . . . . . . . . . .30<br />

B.11 FSC-SERVERCONTROL2-MIB (sc2.mib) . . . . . . . . . . . . . . . . . . . . . . . . .32<br />

B.12 BLADE-MIB (S31.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<br />

B.13 AdaptecArrayController-MIB (aac.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br />

B.14 DESKTRAP-MIB (desktrap.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42<br />

B.15 DPT-SCSI-MIB (dptscsi.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47<br />

B.16 MYLEXRAID-MIB (Mlxraid.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br />

B.17 MYLEXRAID-FJ-MIB (Mlxraidfj.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br />

B.18 FASTTRAK-MIB (promisev1.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br />

B.19 PROMISE-UNIFIED-MIB (promiseraid.mib) . . . . . . . . . . . . . . . . . . . . . . .52<br />

B.20 RAID-Adapter-MIB (megaraid.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54<br />

B.21 UPSMAN (Upsman.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56<br />

B.22 UPS-MIB (RFC1628.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57<br />

B.23 PowerNet-MIB (powernet.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58<br />

B.24 Alert-Definition-Originator-MIB (F5emt2o.mib) . . . . . . . . . . . . . . . . . . . . . .80<br />

B.25 LDSM-MIB (ldsm.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80<br />

B.26 LDCM-MIB (Ldcm.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81<br />

B.27 FUJITSU-SERVERVISOR-MIB (Servervi.mib) . . . . . . . . . . . . . . . . . . . . .82<br />

B.28 RFC1157 (RFC1157.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />

B.29 ROMPILOT-MIB (ROMPILOT.MIB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82<br />

B.30 SW-MIB (fcswitch.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84<br />

B.31 ADAPTECDURALINK-MIB (duralink.mib) . . . . . . . . . . . . . . . . . . . . . . . . .84<br />

B.32 TapeAlert-MIB (tapealrt.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85<br />

B.33 IOMMIB (iommib.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88<br />

B.34 BRIDGE-MIB (trap1493.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />

B.35 RMON-MIB (trap1757.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />

B.36 INTEL-WFM-MIB (WFM.mib ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90<br />

3


4<br />

B.37 EM4513-MIB (unicorn-trap.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114<br />

B.38 NET-SNMP-MIB (net-snmp.mib) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115


A <strong>Trap</strong> <strong>List</strong> Overview<br />

This manual shows an overview of SNMP traps viewable in the ServerView alarm<br />

service and explains how to read the trap lists in this manual.<br />

A.1 Notes<br />

A.1 Notes<br />

In this manual, traps shown as "Not supported" or traps not listed are unsupported. (Including traps<br />

not shown as UNKNOWN and traps shown in the class "4" and "5" alarm list in "A.2 How to read the<br />

trap list" (�pg.5)).<br />

Because the Agents of I/O component traps vary, they are supplied by the various vendors.<br />

Depending on the version of the Agents, message content may change. Refer to the manual provided<br />

with the server for details about messages.<br />

When "ENTERPRISE OID" is a version other than "enterprises.231" the contact representative will<br />

vary depending on the vendor it is supplied by.<br />

A.2 How to read the trap list<br />

The displayed content of trap messages is classed in the following way.<br />

1. Pop up messages<br />

2. OS event logs<br />

3. AlarmService alarm list<br />

4. Alarm list of the AlarmService alarm settings<br />

5. MIB file Help alarm list alarm type<br />

The trap list entries are displayed in the following way.<br />

TRAP-TYPE/<br />

Alarm type<br />

Specific Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system variable)<br />

: Name of the trap.<br />

Corresponding to "5. MIB file Help alarm list alarm type".<br />

: Name of the trap.<br />

Corresponding to "3. AlarmService alarm list" and "4. Alarm list of the<br />

AlarmService alarm settings".<br />

: <strong>List</strong> number of the trap.<br />

: Level of importance (error class) of the trap.<br />

: "1. Pop up messages" and "2. OS event logs".<br />

: Additional explanation or problem solution for the trap.<br />

Remarks<br />

5


6<br />

A <strong>Trap</strong> <strong>List</strong> Overview<br />

A.3 Screen display examples<br />

The screen display examples are as follows:<br />

● Popup<br />

● OS Event log


● AlarmService (Alarm Monitor) alarm list<br />

● Alarm list of the AlarmService alarm settings<br />

A.3 Screen display examples<br />

7


8<br />

A <strong>Trap</strong> <strong>List</strong> Overview<br />

● MIB file Help alarm list<br />

In order to use this display the above screens, you must perform the following operations:<br />

1. Start the ServerView AlarmService.<br />

2. Click AlarmService [Help].<br />

3. Click [Agent alarm information] in the [Contents].<br />

4. Click [RFC1157.mib] in "AlarmMib".<br />

■ Description examples that appear in the mib file.<br />

Description examples that appear in the mib file are shown below.<br />

test<strong>Trap</strong> TRAP-TYPE<br />

ENTERPRISE sniServerMgmt<br />

VARIABLES {<br />

trapServerName,<br />

trapTime<br />

}<br />

DESCRIPTION<br />

"Test trap to verify trap connection."<br />

--#TYPE "Test trap"<br />

--#SUMMARY "Test trap from server %s (no error)."<br />

--#ARGUMENTS { 0 }<br />

--#SEVERITY INFORMATIONAL<br />

--#TIMEINDEX 1<br />

--#HELP "Note: This is no error condition."<br />

--#HELPTAG<br />

--#STATE OPERATIONAL<br />

::= 600


B <strong>Trap</strong> <strong>List</strong><br />

B.1 SNI-TRAP-MIB (trap.mib)<br />

<strong>Trap</strong>s from the ServerView console.<br />

TRAP-TYPE/<br />

Alarm type<br />

sniNWVolSysMounted<br />

Volume SYS is mounted<br />

sniNWSysVolumeDismounted<br />

Volume SYS is dismounted<br />

sniNWVolumeMounted<br />

Volume is mounted<br />

sniNWVolumeDismounted<br />

Volume is dismounted<br />

sniNWDownServer<br />

Server is going down<br />

(NetWare)<br />

sniNWExitToDos<br />

Server exits to DOS<br />

sniNWModuleUnloaded<br />

Module is unloaded<br />

sniNWClearConnection<br />

Connection is cleared<br />

sniNWLoginUser<br />

User logged into server<br />

sniNWCreateBinderyObj<br />

Bindery object created<br />

sniNWDeleteBinderyObj<br />

Bindery object deleted<br />

sniNWChangeSecurity<br />

Security changed (NetWare)<br />

sniNWActivateScreen<br />

Screen activated<br />

sniNWUpdateScreen<br />

Screen updated<br />

sniNWUpdateCursor<br />

Cursor position updated<br />

sniNWKeyWasPressed<br />

Key pressed<br />

sniNWDeactivateScreen<br />

Screen deactivated<br />

sniNWTrusteeChange<br />

Trustee changed (NetWare)<br />

sniNWOpenScreen<br />

Screen opened<br />

table: SNI-TRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231)<br />

Specific<br />

Level of<br />

importance<br />

0 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.1 SNI-TRAP-MIB (trap.mib)<br />

Remarks<br />

Volume SYS is mounted on server %s A Netware monitor<br />

<strong>Trap</strong>. Not supported.<br />

1 CRITICAL Volume SYS is dismounted on server %s ↑<br />

2 INFORMAT<br />

IONAL<br />

3 INFORMAT<br />

IONAL<br />

Volume %s is mounted on server %s ↑<br />

Volume %s is dismounted on server %s ↑<br />

4 CRITICAL Server is going down: %s ↑<br />

7 CRITICAL Server exits to DOS : %s ↑<br />

8 INFORMAT<br />

IONAL<br />

9 INFORMAT<br />

IONAL<br />

10 INFORMAT<br />

IONAL<br />

11 INFORMAT<br />

IONAL<br />

12 INFORMAT<br />

IONAL<br />

13 INFORMAT<br />

IONAL<br />

14 INFORMAT<br />

IONAL<br />

15 INFORMAT<br />

IONAL<br />

16 INFORMAT<br />

IONAL<br />

17 INFORMAT<br />

IONAL<br />

18 INFORMAT<br />

IONAL<br />

19 INFORMAT<br />

IONAL<br />

20 INFORMAT<br />

IONAL<br />

Module %s is unloaded on server %s ↑<br />

A connection is cleared on server %s ↑<br />

A user logged into server %s ↑<br />

A bindery object is created on server %s ↑<br />

A bindery object is deleted on server %s ↑<br />

Security change has occurred on server<br />

%s<br />

A screen is activated on server %s ↑<br />

A screen is updated on server %s ↑<br />

The cursor position is updated on server<br />

%s<br />

A key is pressed on server %s ↑<br />

A screen is deactivated on server %s ↑<br />

Trustee is changed on server %s ↑<br />

A Screen is opened on server %s ↑<br />

↑<br />

↑<br />

9


10<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

sniNWCloseScreen<br />

Screen closed<br />

sniNWModifyDirEntry<br />

Directory entry changed<br />

sniNWNoRelinquishControl<br />

NLM has not relinquished<br />

control<br />

sniNWThreadSwitch<br />

Thread switch has occurred<br />

sniNWModuleLoaded<br />

Module loaded<br />

sniNWCreateProcess<br />

Process created<br />

sniNWDestroyProcess<br />

Process destroyed<br />

sniNWNewPublic<br />

New public symbol<br />

sniNWProtocolBind<br />

Protocol bound<br />

sniNWProtocolUnbind<br />

Protocol unbound<br />

sniNWAllocateConnection<br />

Connection allocated<br />

sniNWLogoutConnection<br />

User logged out<br />

sniNWMLIDRegister<br />

MLID registered<br />

sniNWMLIDDeRegister<br />

MLID deregistered<br />

sniNWDataMigration<br />

File data migrated<br />

sniNWDataDeMigration<br />

File data demigrated<br />

sniNWQueueAction<br />

Queue status changed<br />

sniNWAlert<br />

Alert written<br />

sniNWCreateObject<br />

DS object created<br />

sniNWDeleteObject<br />

DS object deleted<br />

sniNWRenameObject<br />

DS object renamed<br />

sniNWValueChanged<br />

DS object value changed<br />

sniNWCloseFile<br />

File closed<br />

sniNWChangeTime<br />

Time changed (NetWare)<br />

table: SNI-TRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231)<br />

Specific<br />

Level of<br />

importance<br />

21 INFORMAT<br />

IONAL<br />

22 INFORMAT<br />

IONAL<br />

A Screen is closed on server %s ↑<br />

Directory entry is changed on server %s ↑<br />

23 CRITICAL The NLM %s has not relinquished<br />

control on server %s<br />

25 INFORMAT<br />

IONAL<br />

27 INFORMAT<br />

IONAL<br />

28 INFORMAT<br />

IONAL<br />

29 INFORMAT<br />

IONAL<br />

32 INFORMAT<br />

IONAL<br />

33 INFORMAT<br />

IONAL<br />

A thread switch has occurred on server<br />

%s<br />

Module %s is loaded on server %s ↑<br />

A Process is created on server %s ↑<br />

A Process is destroyed on server %s ↑<br />

A new public symbol is registered on<br />

server %s<br />

A protocol is bound to a MLID on server<br />

%s<br />

34 MAJOR A protocol is unbound from a MLID on<br />

server %s<br />

37 INFORMAT<br />

IONAL<br />

38 INFORMAT<br />

IONAL<br />

39 INFORMAT<br />

IONAL<br />

40 INFORMAT<br />

IONAL<br />

41 INFORMAT<br />

IONAL<br />

42 INFORMAT<br />

IONAL<br />

43 INFORMAT<br />

IONAL<br />

44 INFORMAT<br />

IONAL<br />

46 INFORMAT<br />

IONAL<br />

47 INFORMAT<br />

IONAL<br />

48 INFORMAT<br />

IONAL<br />

49 INFORMAT<br />

IONAL<br />

50 INFORMAT<br />

IONAL<br />

51 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A connection is allocated on server %s ↑<br />

A user has logged out of server %s ↑<br />

A MLID is registered on server %s ↑<br />

A MLID is deregistered on server %s ↑<br />

A files data has been migrated on server<br />

%s<br />

A files data has been demigrated on<br />

server %s<br />

A queue is activated, deactivated, created<br />

or deleted on server %s<br />

A Netware Alert message is written to<br />

the console on server %s. Module %s: %s<br />

A Directory Service object is created on<br />

server %s<br />

A Directory Service object is deleted on<br />

server %s<br />

A Directory Service object is renamed on<br />

server %s<br />

A Directory Service object's value<br />

changed on server %s<br />

A file is closed on server %s ↑<br />

Time has changed or a nonuniform time<br />

adjustment has occurred on server %s<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

sniInvPoll<strong>Trap</strong>Exceeded<br />

Threshold exceeded<br />

sniInvPoll<strong>Trap</strong>Underflow<br />

Threshold underflow<br />

sniInvPollDeltaExceeded<br />

DELTA-Threshold exceeded<br />

sniInvDelta<strong>Trap</strong>Underflow<br />

DELTA-Threshold underflow<br />

sniInv<strong>Trap</strong>Invalid<br />

Threshold invalid<br />

sniInv<strong>Trap</strong>Valid<br />

Threshold valid<br />

sniNTDownServer<br />

Server is going down (NT)<br />

sniNTLoginUser<br />

User logged in<br />

sniNTChangeSecurity<br />

Security changed (NT)<br />

sniNTTrusteeChange<br />

Trustee changed (NT)<br />

sniNTAlert<br />

NT Alert written<br />

sniNTChangeTime<br />

Time changed (NT)<br />

sniNTRegChangeName<br />

Keyname changed<br />

sniNTRegChangeAttr<br />

Registry key attributes<br />

changed<br />

sniNTRegChangeLastWrite<br />

Registry last write time<br />

changed<br />

sniNTRegChangeSecurity<br />

Registry key security changed<br />

sniNTFileChangeName<br />

File name modified<br />

sniNTFileChangeDirName<br />

Directory name modified<br />

sniNTFileChangeAttr<br />

File attributes changed<br />

sniNTFileChangeSize<br />

File size changed<br />

sniNTFileChangeLastWrite<br />

File last write time changed<br />

sniNTFileChangeSecurity<br />

File security changed<br />

table: SNI-TRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231)<br />

Specific<br />

Level of<br />

importance<br />

128 INFORMAT<br />

IONAL<br />

129 INFORMAT<br />

IONAL<br />

130 INFORMAT<br />

IONAL<br />

131 INFORMAT<br />

IONAL<br />

132 INFORMAT<br />

IONAL<br />

133 INFORMAT<br />

IONAL<br />

300 INFORMAT<br />

IONAL<br />

301 INFORMAT<br />

IONAL<br />

302 INFORMAT<br />

IONAL<br />

303 INFORMAT<br />

IONAL<br />

304 INFORMAT<br />

IONAL<br />

305 INFORMAT<br />

IONAL<br />

310 INFORMAT<br />

IONAL<br />

311 INFORMAT<br />

IONAL<br />

312 INFORMAT<br />

IONAL<br />

313 INFORMAT<br />

IONAL<br />

320 INFORMAT<br />

IONAL<br />

321 INFORMAT<br />

IONAL<br />

322 INFORMAT<br />

IONAL<br />

323 INFORMAT<br />

IONAL<br />

324 INFORMAT<br />

IONAL<br />

325 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.1 SNI-TRAP-MIB (trap.mib)<br />

Threshold exceeded : %s, on Server %s This message shows<br />

that the threshold<br />

exceeded the value<br />

set in the threshold<br />

manager.<br />

Threshold underflow : %s, on Server %s ↑<br />

DELTA-Threshold exceeded : %s, on<br />

Server %s<br />

DELTA-Threshold underflow : %s, on<br />

Server %s<br />

Threshold Invalid: %s, on Server %s This message refers<br />

to the value set in the<br />

threshold manager.<br />

Threshold Valid: %s, on Server %s ↑<br />

Server is going down : %s<br />

A user logged into server %s<br />

Security change has occurred on server<br />

%s<br />

A trustee is changed on server %s<br />

An NT Alert message is written to the<br />

eventlog (Control String: %s) on server<br />

%s.<br />

Time has changed or a nonuniform time<br />

adjustment has occurred on server %s<br />

Keyname in registry has been changed on<br />

server %s<br />

Attributes for a key or its subtree in<br />

registry has been changed on server %s<br />

Last write time for a key or its subtree in<br />

registry has been changed on server %s<br />

Security for a key or its subtree in<br />

registry has been changed on server %s<br />

A file name has been changed, created or<br />

deleted on server %s<br />

A directory name has been changed,<br />

created or deleted on server %s<br />

File or directory attributes have been<br />

changed on server %s<br />

File size has been changed on server %s<br />

Last write time on a file has been<br />

changed on server %s<br />

Security on a file has been changed on<br />

server %s<br />

↑<br />

↑<br />

Remarks<br />

11


12<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

sniNTEventLogError<br />

Eventlog entry: error<br />

sniNTEventLogWarning<br />

Eventlog entry: warning<br />

sniNTEventLogInformation<br />

Eventlog entry: information<br />

sniNTEventLogSuccess<br />

Eventlog entry: success audit<br />

sniNTEventLogFailure<br />

Eventlog entry: failure audit<br />

330 INFORMAT<br />

IONAL<br />

331 INFORMAT<br />

IONAL<br />

332 INFORMAT<br />

IONAL<br />

333 INFORMAT<br />

IONAL<br />

334 INFORMAT<br />

IONAL<br />

B.2 SNI-MYLEX-MIB (mylex.mib)<br />

Error entry written to eventlog on server<br />

%s<br />

Warning entry written to eventlog on<br />

server %s<br />

Warning entry written to eventlog on<br />

server %s<br />

Informational entry written to eventlog<br />

on server %s<br />

Audit success entry written to eventlog<br />

on server %s<br />

Failure audit entry written to eventlog on<br />

server %s<br />

<strong>Trap</strong>s from the Mylex Disk Array Controller. For message details, refer to the RAID controller (RAID<br />

Manager (GAM: Global Array Manager)) manual.<br />

TRAP-TYPE/<br />

Alarm type<br />

mylexAutoRebuildStarted<br />

Automatic rebuild started<br />

mylexManualRebuildStarted<br />

Manual rebuild started<br />

mylexRebuildDone<br />

Rebuild done<br />

mylexRebuildCanceled<br />

Rebuild cancelled<br />

mylexRebuildStatus<br />

Rebuild status<br />

mylexRebuildError<br />

Rebuild error<br />

mylexRebuildNewDeviceFail<br />

ed<br />

Rebuild device failed<br />

mylexRebuildLogicalDriveFai<br />

led<br />

Rebuild drive failed<br />

mylexParityCheckStarted<br />

Parity check started<br />

mylexParityCheckDone<br />

Parity check done<br />

table: SNI-TRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231)<br />

Specific<br />

table: SNI-MYLEX-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

200 INFORMAT<br />

IONAL<br />

201 INFORMAT<br />

IONAL<br />

202 INFORMAT<br />

IONAL<br />

203 INFORMAT<br />

IONAL<br />

204 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Automatic rebuild of device %d on<br />

channel %d was started at disk array<br />

adapter in slot %d. The standby device<br />

%d at channel %d will be used (Server<br />

%s).<br />

Manual rebuild was started at disk array<br />

adapter in slot %d at server %s.<br />

Rebuild was successfully completed at<br />

disk array adapter in slot %d (Server %s).<br />

Rebuild was cancelled at disk array<br />

adapter in slot %d (Server %s).<br />

Rebuild status at disk array adapter in slot<br />

%d: current drive=%d, drive size=%d<br />

MBytes; %d MBytes remaining (Server<br />

%s).<br />

205 MAJOR Rebuild error at disk array adapter in slot<br />

%d: %d bad blocks detected (Server %s).<br />

206 MAJOR Rebuild finished at disk array adapter in<br />

slot %d: new device failed (Server %s).<br />

207 MAJOR Rebuild finished at disk array adapter in slot<br />

%d: logical drive failed, %d bad blocks<br />

detected (Server %s).<br />

208 INFORMAT<br />

IONAL<br />

209 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Parity check was started at disk array<br />

adapter in slot %d (Server %s).<br />

Parity check was successfully completed<br />

at disk array adapter in slot %d (Server<br />

%s).<br />

Remarks<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

mylexParityCheckCanceled<br />

Parity check cancelled<br />

mylexParityCheckStatus<br />

Parity check status<br />

mylexParityCheckError<br />

Parity check error<br />

mylexParityCheckLogicalDriv<br />

eFailed<br />

Parity check: drive failed<br />

mylexLogicalDriveOffline<br />

Logical drive offline<br />

mylexLogicalDriveCritical<br />

Logical drive critical<br />

mylexLogicalDriveOnline<br />

Logical drive online<br />

mylexPhysicalDeviceDied<br />

Physical device dead<br />

mylexPhysicalDeviceAlive<br />

Physical device online<br />

mylexWriteBackError<br />

Write back error<br />

mylexStateChangeTableFull<br />

Cache change table full<br />

mylexAdapterDied<br />

Disk controller died<br />

mylexAutoRebuildStarted2<br />

Automatic rebuild started<br />

mylexManualRebuildStarted2<br />

Manual rebuild started<br />

mylexRebuildDone2<br />

Rebuild done<br />

mylexRebuildCanceled2<br />

Rebuild cancelled<br />

mylexRebuildError2<br />

Rebuild error<br />

mylexRebuildNewDeviceFail<br />

ed2<br />

Rebuild device failed<br />

mylexRebuildLogicalDriveFai<br />

led2<br />

Rebuild drive failed<br />

table: SNI-MYLEX-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

210 INFORMAT<br />

IONAL<br />

211 INFORMAT<br />

IONAL<br />

Parity check was cancelled at disk array<br />

adapter in slot %d (Server %s).<br />

Parity check status at disk array adapter<br />

in slot %d: current drive=%d, drive<br />

size=%d MB; %d MBytes remaining<br />

(Server %s).<br />

212 MAJOR Parity check error at disk array adapter in<br />

slot %d: %d bad blocks detected (Server<br />

%s).<br />

213 MAJOR Parity check finished at disk array adapter in<br />

slot %d; logical drive failed: %d bad blocks<br />

detected (Server %s).<br />

214 CRITICAL Logical drive %d at disk array adapter in<br />

slot %d is offline (Server %s).<br />

215 MAJOR Logical drive %d at disk array adapter in<br />

slot %d is critical (Server %s).<br />

216 INFORMAT<br />

IONAL<br />

Logical drive %d at disk array adapter in<br />

slot %d is online (Server %s).<br />

217 CRITICAL Physical device %d on channel %d at<br />

disk array adapter in slot %d is DEAD<br />

(Server %s).<br />

218 INFORMAT<br />

IONAL<br />

Physical device %d on channel %d at<br />

disk array adapter in slot %d is now<br />

ONLINE (Server %s).<br />

219 MAJOR Controller cache write back error at disk<br />

array adapter in slot %d: %d bad blocks<br />

(Server %s).<br />

220 MAJOR Cache state-change table full at disk<br />

array adapter in slot %d (Server %s).<br />

221 CRITICAL Connection to disk array controller in slot<br />

%d on server %s lost.<br />

222 INFORMAT<br />

IONAL<br />

223 INFORMAT<br />

IONAL<br />

224 INFORMAT<br />

IONAL<br />

225 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Automatic rebuild of system drive %d<br />

was started at disk array adapter in slot<br />

%d at server %s.<br />

Manual rebuild of system drive %d was<br />

started at disk array adapter in slot %d at<br />

server %s.<br />

Rebuild of system drive %d was<br />

successfully completed at disk array<br />

adapter in slot %d at server %s.<br />

Rebuild of system drive %d was<br />

cancelled at disk array adapter in slot %d<br />

at server %s.<br />

226 MAJOR Rebuild error on system drive %d at disk<br />

array adapter in slot %d at server %s.<br />

227 MAJOR Rebuild of system drive %d finished at<br />

disk array adapter in slot %d: new device<br />

failed at server %s.<br />

228 MAJOR Rebuild of system drive %d finished at<br />

disk array adapter in slot %d: system<br />

drive failed at server %s.<br />

B.2 SNI-MYLEX-MIB (mylex.mib)<br />

Remarks<br />

13


14<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

mylexInitializationStarted<br />

Initialization started<br />

mylexInitializationDone<br />

Initialization done<br />

mylexInitializationCanceled<br />

Initialization canceled<br />

mylexInitializationFailed<br />

Initialization failed<br />

mylexSystemDriveCreated<br />

System drive created<br />

mylexSystemDriveDeleted<br />

System drive deleted<br />

mylexRaidExpansionStarted<br />

RAID expansion started<br />

mylexRaidExpansionDone<br />

RAID expansion done<br />

mylexRaidExpansionFailed<br />

RAID expansion failed<br />

mylexSystemDriveBadBlock<br />

Bad block<br />

mylexSystemDriveSizeChang<br />

ed<br />

System drive size changed<br />

mylexRaidTypeChanged<br />

RAID type changed<br />

mylexPhysicalDeviceHotspare<br />

Physical device hotspare<br />

mylexPhysicalDeviceHardErr<br />

or<br />

Physical device hard error<br />

mylexPhysicalDeviceSoftErro<br />

r<br />

Physical device soft error<br />

mylexPhysicalDeviceParityEr<br />

ror<br />

Physical device parity error<br />

mylexPhysicalDeviceMiscErr<br />

or<br />

Physical device miscellaneous<br />

error<br />

table: SNI-MYLEX-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

229 INFORMAT<br />

IONAL<br />

230 INFORMAT<br />

IONAL<br />

231 INFORMAT<br />

IONAL<br />

Initialization of system drive %d started<br />

at disk array adapter in slot %d at server<br />

%s.<br />

Initialization of system drive %d<br />

successfully finished at disk array adapter<br />

in slot %d at server %s.<br />

Initialization of system drive %d<br />

canceled at disk array adapter in slot %d<br />

at server %s.<br />

232 MAJOR Initialization of system drive %d failed at<br />

disk array adapter in slot %d at server<br />

%s.<br />

233 INFORMAT<br />

IONAL<br />

234 INFORMAT<br />

IONAL<br />

235 INFORMAT<br />

IONAL<br />

236 INFORMAT<br />

IONAL<br />

New system drive %d created at disk<br />

array adapter in slot %d at server %s.<br />

System drive %d deleted at disk array<br />

adapter in slot %d at server %s.<br />

RAID capacity expansion on system<br />

drive %d started at disk array adapter in<br />

slot %d at server %s.<br />

RAID capacity expansion on system<br />

drive %d successfully finished at disk<br />

array adapter in slot %d at server %s.<br />

237 MAJOR RAID capacity expansion failed on<br />

system drive %d at disk array adapter in<br />

slot %d at server %s.<br />

238 MINOR Bad block(s) detected on system drive<br />

%d at disk array adapter in slot %d at<br />

server %s.<br />

239 INFORMAT<br />

IONAL<br />

240 INFORMAT<br />

IONAL<br />

250 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Size of system drive %d was changed at<br />

disk array adapter in slot %d at server<br />

%s.<br />

RAID type of system drive %d was<br />

changed at disk array adapter in slot %d<br />

at server %s.<br />

Physical device %d on channel %d at<br />

disk array adapter in slot %d is now<br />

HOTSPARE (Server %s).<br />

251 MINOR Hard error occurred at physical device<br />

%d on channel %d at disk array adapter<br />

in slot %d (Server %s).<br />

252 MINOR Soft error occurred at physical device %d<br />

on channel %d at disk array adapter in<br />

slot %d (Server %s).<br />

253 MINOR Parity error occurred at physical device<br />

%d on channel %d at disk array adapter<br />

in slot %d (Server %s).<br />

254 MINOR Miscellaneous error occurred at physical<br />

device %d on channel %d at disk array<br />

adapter in slot %d (Server %s).<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

mylexPhysicalDevicePrefailur<br />

e<br />

Physical device prefailure<br />

mylexPhysicalDeviceUnconfi<br />

gured<br />

Physical device unconfigured<br />

mylexPhysicalDeviceAdded<br />

Physical device added<br />

mylexPhysicalDeviceRemove<br />

d<br />

Physical device removed<br />

mylexWriteBackError2<br />

Write back error<br />

mylexGamDriverMissing<br />

Missing GAM driver<br />

mylexGamDriverIncorrectVer<br />

sion<br />

Incorrect GAM driver version<br />

mylexSMARTFailurePredicte<br />

d<br />

SMART predicted disk failure<br />

mylexSMARTConfigurationC<br />

hanged<br />

SMART configuration<br />

changed<br />

mylexBBUFound<br />

BBU found<br />

mylexBBUPowerLow<br />

BBU power low<br />

mylexBBUPowerOK<br />

BBU power OK<br />

table: SNI-MYLEX-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

255 MAJOR Prefailure alert from physical device %d<br />

on channel %d at disk array adapter in<br />

slot %d (Server %s). Device will fail in<br />

near future!<br />

256 MAJOR Physical device %d on channel %d at<br />

disk array adapter in slot %d is<br />

unconfigured (Server %s).<br />

257 MAJOR Physical device %d on channel %d at<br />

disk array adapter in slot %d was added<br />

(Server %s).<br />

258 MAJOR Physical device %d on channel %d at<br />

disk array adapter in slot %d was<br />

removed (Server %s).<br />

260 MAJOR Controller cache write back error at disk<br />

array adapter in slot %d (Server %s).<br />

261 MINOR GAM driver is either not installed or has<br />

failed to start; required version: %s<br />

(server %s).<br />

262 MINOR Incorrect version of GAM driver installed<br />

(%s); required version: %s (server %s).<br />

270 CRITICAL SMART predicts failure for disk %d on<br />

channel %d at disk array adapter in slot<br />

%d (Server %s).<br />

271 INFORMAT<br />

IONAL<br />

275 INFORMAT<br />

IONAL<br />

SMART configuration has been changed<br />

for disk %d on channel %d at disk array<br />

adapter in slot %d (Server %s).<br />

A Battery Backup Unit was found on<br />

SCSI controller in slot %d (Server %s).<br />

276 CRITICAL The Battery Backup Unit power on SCSI<br />

controller in slot %d is low (Server %s).<br />

If this messages happens without power<br />

failure, replace the BBU.<br />

277 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The Battery Backup Unit power on SCSI<br />

controller in slot %d is OK (Server %s).<br />

B.2 SNI-MYLEX-MIB (mylex.mib)<br />

Remarks<br />

15


16<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

<strong>Trap</strong>s from the ServerView agent or RSB.<br />

TRAP-TYPE/<br />

Alarm type<br />

test<strong>Trap</strong><br />

Test trap<br />

fanError<br />

Fan failed<br />

tempOk<br />

Temperature normal<br />

tempWarn<br />

Temperature warning<br />

tempCritical<br />

Temperature critical<br />

trapOnBattery<br />

AC failed, on battery<br />

trapOnMains<br />

AC OK<br />

selftestWarning<br />

Controller selftest warning<br />

selftestError<br />

Controller selftest error<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

600 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Test trap from server %s (no error). No error.<br />

601 CRITICAL Fan %d failed in cabinet %d of server<br />

%s.<br />

602 INFORMAT<br />

IONAL<br />

Temperature at sensor %d in cabinet %d<br />

of server %s is within normal range.<br />

603 MAJOR Temperature at sensor %d in cabinet %d<br />

of server %s has reached the warning<br />

level.<br />

604 CRITICAL Temperature at sensor %d in cabinet %d<br />

of server %s has reached the critical level.<br />

606 CRITICAL AC failure. Cabinet %d is running on<br />

battery power since %d seconds. In %d<br />

minutes server %s will shutdown.<br />

607 INFORMAT<br />

IONAL<br />

Mains returned after power failure in cabinet<br />

%d at server %s.<br />

608 MINOR The Server Management controller in<br />

cabinet %d has detected an minor<br />

problem during selftest of server %s.<br />

609 CRITICAL The Server Management controller in<br />

cabinet %d of server %s failed.<br />

Remarks<br />

A fan error occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

The internal<br />

temperature of the<br />

server is within the<br />

normal range. No<br />

error.<br />

A device temperature<br />

error occurred. Check<br />

the room temperature.<br />

If room temperature is<br />

normal check whether<br />

the fan has failed.<br />

Other errors in<br />

hardware are possible.<br />

Refer to "Contact<br />

Information" in "Read<br />

me First", and contact<br />

your maintenance<br />

engineer.<br />

Running on UPS<br />

battery power.<br />

Check that UPS<br />

power cables are not<br />

unplugged and there<br />

has been no power<br />

interruption.<br />

Stopped running on<br />

the UPS battery.<br />

No problem. If<br />

multiple messages are<br />

detected, it is possible<br />

that the Server<br />

Management<br />

controller has failed.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.


TRAP-TYPE/<br />

Alarm type<br />

svCommunicationFailure<br />

Communication lost<br />

scbUnconfiguredUPSDetected<br />

UPS not configured<br />

scbUPSNotdetected<br />

UPS not detected<br />

scbUnconfiguredBBUDetected<br />

BBU not configured<br />

scbBBUNotdetected<br />

BBU not detected<br />

notEnoughCabinets<br />

SE's missing<br />

tooManyCabinets<br />

Too many SE's<br />

cabinetSwitchedOff<br />

Cabinet switched off<br />

cabinetSwitchedOn<br />

Cabinet switched on<br />

internalError<br />

Internal error<br />

serverShutdown<br />

Server shutdown<br />

610 MINOR Communication with the Server<br />

Management controller in cabinet %d of<br />

server %s lost.<br />

611 INFORMAT<br />

IONAL<br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

UPS detected by server %s, but no UPS<br />

is configured.<br />

612 MAJOR A UPS is configured but no UPS detected<br />

by server %s.<br />

613 INFORMAT<br />

IONAL<br />

614 INFORMAT<br />

IONAL<br />

BBU detected by server %s, but no BBU is<br />

configured.<br />

A BBU is configured but no BBU is<br />

detected by server %s.<br />

615 MAJOR The actual number of storage extensions<br />

at server %s is lower than the configured.<br />

616 MINOR The actual number of storage extensions<br />

at server %s is higher than the<br />

configured.<br />

617 INFORMAT<br />

IONAL<br />

618 INFORMAT<br />

IONAL<br />

620 INFORMAT<br />

IONAL<br />

621 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Cabinet %d was switched off because of<br />

%s (server %s).<br />

Cabinet %d was switched on because of<br />

%s (server %s).<br />

Internal error #%d in server management<br />

controller software. (module %s at server<br />

%s).<br />

The reason %s causes a shutdown at<br />

server %s.<br />

Remarks<br />

If recovered in event<br />

ID:10636 there is no<br />

problem.<br />

If not restored, refer<br />

to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

It is possible that<br />

there is an error in the<br />

settings. Recheck the<br />

settings.<br />

If there is no error in<br />

the settings it is<br />

possible that a UPS<br />

error occurred. Refer<br />

to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

There is an error in<br />

the configuration of<br />

the external memory<br />

device. Recheck this.<br />

Server%s has turned<br />

off.<br />

Server%s has turned<br />

on.<br />

This is a software<br />

error. Specify the<br />

name of the module<br />

and, refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Shutdown at the<br />

server is performed<br />

by ordering<br />

shutdown.<br />

17


18<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

fanCriticalError<br />

Fan will fail<br />

cabinetNotConfigured<br />

Cabinet not configured<br />

powerSupplyRemoved<br />

Power supply removed<br />

powerSupplyAdded<br />

Power supply added<br />

powerSupplyFailed<br />

Power supply failed<br />

powerSupplyOk<br />

Power supply OK<br />

powerSupplyStatusCritical<br />

Power supply critical<br />

fanOk<br />

Fan OK<br />

tempSensorBroken<br />

Temperature sensor broken<br />

serverManagementDisabled<br />

Server management disabled<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

622 MAJOR Fan %d will fail in near future in cabinet<br />

%d of server %s.<br />

623 INFORMAT<br />

IONAL<br />

624 INFORMAT<br />

IONAL<br />

625 INFORMAT<br />

IONAL<br />

Cabinet %d at server %s is not<br />

configured. Depending on the system<br />

type, run Server Configuration Utility<br />

(SCU) or Storage Extension Manager<br />

(SEMAN) and configure the cabinet!<br />

Power supply %d in cabinet %d at server<br />

%s was removed.<br />

Power supply %d in cabinet %d at server<br />

%s was added.<br />

626 MAJOR Power supply %d in cabinet %d at server<br />

%s failed.<br />

627 INFORMAT<br />

IONAL<br />

Power supply %d in cabinet %d at server<br />

%s is working again.<br />

628 CRITICAL Insufficiant operating power supplies<br />

available in cabinet %d at server %s.<br />

629 INFORMAT<br />

IONAL<br />

Fan %d in cabinet %d of server %s is<br />

working again.<br />

630 MAJOR Temperature sensor %d in cabinet %d of<br />

server %s is broken or not connected.<br />

631 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Server management BIOS on server %s<br />

is disabled. Enable it to have full server<br />

management functionality!<br />

Remarks<br />

This predicts a fan<br />

error. A failure will<br />

not occur soon.<br />

"Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

The cabinet is not<br />

correctly configured.<br />

Set again.<br />

The power supply<br />

unit was removed by<br />

the operator.<br />

The power supply<br />

unit was added by the<br />

operator.<br />

The PSU has failed.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

This message appears<br />

after the power<br />

supply unit has been<br />

attached.<br />

Install the power<br />

supply unit.<br />

This message shows<br />

that the fan has<br />

returned to normal.<br />

This message appears<br />

when a fan is<br />

replaced.<br />

Temperature sensor<br />

may be faulty.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

In order to enable the<br />

server management,<br />

perform settings<br />

using the<br />

maintenance tools<br />

attached to the<br />

hardware.


trapAcFail<br />

AC failed<br />

TRAP-TYPE/<br />

Alarm type<br />

trapDuplicateCabinetId<br />

Duplicate cabinet ID<br />

trapEventLog<br />

Error in event log<br />

tempSensorOk<br />

Temperature sensor OK<br />

svCommunicationEstablished<br />

Communication established<br />

correctableMemErrorAddr<br />

Correctable memory error<br />

uncorrectableMemErrorAddr<br />

Uncorrectable memory error<br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

632 CRITICAL AC failure in cabinet %d of server %s. This message is stored<br />

when performing UPS<br />

scheduled operations.<br />

There is no problem in<br />

this case.<br />

When not performing<br />

UPS scheduled<br />

operations, there is a<br />

possibility of a power<br />

supply error. Refer to<br />

"Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

633 MAJOR Two or more cabinets have the same ID<br />

%d on server %s.<br />

634 MAJOR An error was recorded on server %s. See<br />

server management event / error log<br />

(Recovery) for detailed information.<br />

635 INFORMAT<br />

IONAL<br />

636 INFORMAT<br />

IONAL<br />

637 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Temperature sensor %d in cabinet %d of<br />

server %s is working again.<br />

Communication with the Server<br />

Management controller in cabinet %d of<br />

server %s established again.<br />

Correctable memory error at address %d<br />

in cabinet %d of server %s.<br />

638 CRITICAL Uncorrectable memory error at address<br />

%d in cabinet %d of server %s.<br />

Remarks<br />

There is an error in<br />

the system<br />

configuration.<br />

Set the configuration<br />

again.<br />

An error occurred<br />

during POST.<br />

Refer to the<br />

information stored in<br />

"Action" and "Error<br />

buffer" in<br />

ServerView.<br />

This message appears<br />

when the temperature<br />

sensor recovers.<br />

This message appears<br />

when communication<br />

with the Server<br />

Management<br />

controller has<br />

recovered.<br />

An SBE (memory<br />

single bit error) has<br />

occurred.<br />

There is no effect<br />

because of the<br />

existence of ECC<br />

memory.<br />

An MBE (memory<br />

multibit error) has<br />

occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

19


20<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

correctableMemErrorBank<br />

Correctable memory error #1<br />

uncorrectableMemErrorBank<br />

Uncorrectable memory error<br />

#1<br />

correctableMemErrorModule<br />

Correctable memory error #2<br />

uncorrectableMemErrorModul<br />

e<br />

Uncorrectable memory error<br />

#2<br />

correctableMemError<br />

Correctable memory error #3<br />

uncorrectableMemError<br />

Uncorrectable memory error<br />

#3<br />

powerOffTimeReached<br />

Power off time reached<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

639 INFORMAT<br />

IONAL<br />

Correctable memory error at bank %d in<br />

cabinet %d of server %s.<br />

640 CRITICAL Uncorrectable memory error at bank %d<br />

in cabinet %d of server %s.<br />

641 INFORMAT<br />

IONAL<br />

Correctable memory error at module %d<br />

in cabinet %d of server %s.<br />

642 CRITICAL Uncorrectable memory error at module<br />

%d in cabinet %d of server %s.<br />

643 INFORMAT<br />

IONAL<br />

Correctable memory error in cabinet %d<br />

of server %s.<br />

644 CRITICAL Uncorrectable memory error in cabinet<br />

%d of server %s.<br />

645 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The power-off time is reached in cabinet<br />

%d on server %s! System shutdown in<br />

%d minutes.<br />

Remarks<br />

An SBE (memory<br />

single bit) has<br />

occurred.<br />

This error has no<br />

effect as ECC<br />

memory is being<br />

used.<br />

An MBE (memory<br />

multibit error) has<br />

occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

An SBE (memory<br />

single bit error) has<br />

occurred.<br />

This error has no<br />

effect as ECC<br />

memory is being<br />

used.<br />

An MBE (memory<br />

multibit error) has<br />

occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

An SBE (memory<br />

single bit error) has<br />

occurred.<br />

This error has no<br />

effect as ECC<br />

memory is being<br />

used.<br />

An MBE (memory<br />

multibit error) has<br />

occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Shut down is<br />

performed due to an<br />

order by the<br />

ServerView console<br />

or a power off<br />

scheduled in<br />

ServerView.


TRAP-TYPE/<br />

Alarm type<br />

frontDoorStatusChanged<br />

Front door status changed<br />

housingOpenStatusChanged<br />

Housing open status changed<br />

sniScRedundantFanFailed<br />

Redundant fan failed<br />

sniScRedundantPowerSupply<br />

Failed<br />

Redundant power supply<br />

failed<br />

sniScVoltageOk<br />

Voltage OK<br />

sniScVoltageTooLow<br />

Voltage too low<br />

sniScVoltageTooHigh<br />

Voltage too high<br />

sniScFanAdded<br />

Fan added<br />

sniScFanRemoved<br />

Fan removed<br />

646 INFORMAT<br />

IONAL<br />

647 INFORMAT<br />

IONAL<br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

The front door status of cabinet %d on<br />

server %s has changed.<br />

The housing open status of cabinet %d on<br />

server %s has changed.<br />

648 MAJOR The redundant fan %d failed in cabinet<br />

%d of server %s. System can become<br />

critical if another fan in this group fails.<br />

649 MAJOR Redundant power supply %d in cabinet<br />

%d at server %s failed. System can<br />

become critical if another power supply<br />

fails.<br />

650 INFORMAT<br />

IONAL<br />

Power supply voltage %d (%s) in cabinet<br />

%d at server %s is within normal range<br />

again.<br />

651 CRITICAL Power supply voltage %d (%s) in cabinet<br />

%d at server %s is too low.<br />

652 CRITICAL Power supply voltage %d (%s) in cabinet<br />

%d at server %s is too high.<br />

653 INFORMAT<br />

IONAL<br />

654 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The fan %d was added into cabinet %d of<br />

server %s.<br />

The fan %d was removed from cabinet<br />

%d of server %s.<br />

Remarks<br />

The door has been<br />

opened or closed by<br />

the operator.<br />

The cover of the<br />

server has been<br />

opened or closed by<br />

the operator.<br />

A redundant fan<br />

failure has occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

A redundant power<br />

supply failure has<br />

occurred.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

The server voltage<br />

has recovered.<br />

There is no problem.<br />

A problem may have<br />

occurred with the<br />

power supply unit,<br />

AC power supply or<br />

the base board etc.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

A problem may have<br />

occurred with the<br />

power supply unit,<br />

AC power supply or<br />

the base board etc.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

The fan was added by<br />

the operator.<br />

The fan was removed<br />

by the operator.<br />

21


22<br />

B <strong>Trap</strong> <strong>List</strong><br />

sniScShutdownCancelled<br />

Shutdown cancelled<br />

sniScCpuSpeedChanged<br />

CPU speed changed<br />

sieScPowerOn<br />

Power on<br />

sieScNoBootCpu<br />

No boot cpu<br />

sieScPostError<br />

Post error<br />

TRAP-TYPE/<br />

Alarm type<br />

sieScSetupEntered<br />

Setup entered<br />

sieScBootError<br />

Boot error<br />

sieScBootWatchdogExpired<br />

Boot watchdog expired<br />

sieScSoftwareWatchdogExpir<br />

ed<br />

Software watchdog expired<br />

sieScUserAuthenticationFailur<br />

e<br />

User authentication failure<br />

sieScDiagnosticBoot<br />

Diagnostic boot<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

655 INFORMAT<br />

IONAL<br />

656 INFORMAT<br />

IONAL<br />

657 INFORMAT<br />

IONAL<br />

658 INFORMAT<br />

IONAL<br />

659 INFORMAT<br />

IONAL<br />

660 INFORMAT<br />

IONAL<br />

661 INFORMAT<br />

IONAL<br />

662 INFORMAT<br />

IONAL<br />

663 INFORMAT<br />

IONAL<br />

Shutdown at server %s cancelled by the<br />

user.<br />

CPU speed at server %s changed to %d<br />

percent of its maximum speed. The CPU<br />

speed can be changed by the server<br />

management because of temperature<br />

problems.<br />

The reason %s causes a power on at<br />

server %s.<br />

System boot of the server %s failed,<br />

because no valid boot cpu available.<br />

The reason %s causes a power on at<br />

server %s.<br />

This is an operation.<br />

The speed of the CPU<br />

is lowered because of<br />

the high temperature<br />

of the CPU.<br />

Check CPU<br />

temperature.<br />

A broken fan may be<br />

causing the<br />

temperature of the<br />

CPU to rise.<br />

This message appears<br />

when the power<br />

supply is turned on.<br />

Check the system.<br />

A CPU error may<br />

have occurred.<br />

IF this occurs<br />

frequently, refer to<br />

"Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

The bios setup is entered at server %s. Setup operations have<br />

been performed by<br />

the operator.<br />

No bootable operation system found at<br />

server %s.<br />

Check the system.<br />

Boot watchdog of server %s expired. Operations were<br />

performed for the<br />

amount of retry<br />

counters set.<br />

Set the retry counters<br />

again.<br />

Software watchdog of server %s expired. Operations were<br />

performed for the<br />

amount of retry<br />

counters set.<br />

Set the retry counters<br />

again.<br />

664 MAJOR User authentication failure detected at<br />

server %s, interface %d, performing<br />

protocol %s.<br />

665 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Server %s is performing a diagnostic<br />

boot.<br />

Remarks<br />

Check the<br />

authentication<br />

operations.<br />

Diagnostic operations<br />

are performed by the<br />

operator.


TRAP-TYPE/<br />

Alarm type<br />

sieScBootRetryCountZero<br />

Boot retry counter zero<br />

sieScMessageLogFull<br />

Message log full<br />

memErrorModulePrefailure<br />

Memory module prefailure<br />

memErrorModuleFailing<br />

Memory module failing<br />

memErrorModuleReplaced<br />

Memory module replaced<br />

sniScPowerSupplyRedundanc<br />

yLost<br />

Power supply redundancy lost<br />

sieScMessageLogWarning<br />

Message log warning<br />

666 MAJOR Boot retry counter is zero on server %s.<br />

On next critical error shutdown the server<br />

will no longer try to reboot. System will<br />

run diagnostic system or switch off.<br />

667 MINOR The System Event Log on server %s in<br />

cabinet %d is full. No more messages can<br />

be logged. Please clear unneeded log<br />

entries as soon as possible!<br />

668 MAJOR Memory module failure is predicted for<br />

module %d in cabinet %d of server %s.<br />

669 MAJOR Memory module %d in cabinet %d of<br />

server %s is failing. Too many errors<br />

have occured.<br />

B.3 SNI-SERVER-CONTROL-MIB (sc.mib)<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

670 MAJOR Memory module module %d in cabinet<br />

%d of server %s had failed<br />

and was replaced by a hot-spare module.<br />

671 MINOR Power supply redundancy in cabinet %d<br />

at server %s lost. System will become<br />

critical if a power supply fails.<br />

672 MINOR The System Event Log for cabinet %d at<br />

server %s has exceeded %d%% of its<br />

capacity.<br />

Remarks<br />

Operations were<br />

performed for the<br />

amount of retry<br />

counters set.<br />

Set the retry counters<br />

again.<br />

Clear the unnecessary<br />

System Event Log<br />

using the<br />

maintenance tools<br />

attached to the<br />

hardware.<br />

This predicts a<br />

memory error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Warning predicting a<br />

memory error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Memory error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Power supply unit<br />

error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

This predicts a<br />

System Event Log.<br />

Clear the unnecessary<br />

System Event Log<br />

using the<br />

maintenance tools<br />

attached to the<br />

hardware.<br />

23


24<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

sieScCpuPrefailure<br />

CPU prefailure<br />

sieScPowerFail<br />

Power failed<br />

sieScBiosSelftestError<br />

Critical BIOS selftest error<br />

sieScBiosSelftestWatchdogEx<br />

pired<br />

BIOS selftest watchdog<br />

expired<br />

sniScVoltageFailure<br />

Voltage out of range<br />

sniScBatteryVoltagePrefailure<br />

Battery failure predicted<br />

table: SNI-SERVER-CONTROL-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

673 MAJOR CPU failure is predicted for CPU %d in<br />

cabinet %d of server %s.<br />

674 CRITICAL DC power failure in cabinet %d of server<br />

%s.<br />

675 CRITICAL A critical error happend while BIOS<br />

selftest in cabinet %d of server %s.See<br />

server management message log<br />

(recovery log) for detailed information.<br />

676 MAJOR BIOS selftest watchdog of server %s<br />

expired.<br />

677 CRITICAL Power supply voltage %d (%s) in cabinet<br />

%d at server %s is out of range.<br />

678 MAJOR Battery voltage %d (%s) in cabinet %d at<br />

server %s: Battery is predicted to fail in<br />

near future.<br />

Remarks<br />

Warning predicting a<br />

CPU error.<br />

Contact your nearest<br />

maintenance<br />

engineer.<br />

Power supply unit<br />

error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

An error has been<br />

detected during BIOS<br />

selftest.<br />

For details refer to<br />

SEL and, refer to<br />

"Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

An error has been<br />

detected during BIOS<br />

selftest.<br />

For details refer to<br />

SEL and, refer to<br />

"Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

Power supply unit<br />

error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

This predicts a power<br />

supply unit error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.


B.4 SNI-SERVERVIEW-MIB (serverview.mib)<br />

ServerView console traps.<br />

TRAP-TYPE/<br />

Alarm type<br />

sniSvGeneric<strong>Trap</strong>Forward<br />

ServerView alarm received<br />

sniSvPagerOff<br />

Pager turn off<br />

sniSvServerStateChanged<br />

Server changed state<br />

sniSvPassThrough<strong>Trap</strong>Forwar<br />

d<br />

ServerView alarm passed<br />

through<br />

sieSvAlarmServiceCommand<br />

Alarm Service Command<br />

fscSvServerAdded<br />

Server added<br />

fscSvServerRemoved<br />

Server removed<br />

fscSvServerChanged<br />

Server changed<br />

fscSvServerStatusChanged<br />

Server status changed<br />

fscSvGroupAdded<br />

Group added<br />

fscSvGroupRemoved<br />

Group removed<br />

fscSvGroupChanged<br />

Group changed<br />

fscSvExploreServer<br />

Explore server<br />

fscAsTestMail<br />

Alarm Service Test Mail<br />

fscAsTestPager<br />

Alarm Service Test Pager<br />

fscAsStop<strong>Trap</strong><strong>List</strong>enService<br />

Alarm Service Stop <strong>Trap</strong><br />

<strong>List</strong>en Service<br />

B.4 SNI-SERVERVIEW-MIB (serverview.mib)<br />

table: SNI-SERVERVIEW-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

700 INFORMAT<br />

IONAL<br />

701 INFORMAT<br />

IONAL<br />

702 INFORMAT<br />

IONAL<br />

703 INFORMAT<br />

IONAL<br />

704 INFORMAT<br />

IONAL<br />

705 INFORMAT<br />

IONAL<br />

706 INFORMAT<br />

IONAL<br />

707 INFORMAT<br />

IONAL<br />

708 INFORMAT<br />

IONAL<br />

709 INFORMAT<br />

IONAL<br />

710 INFORMAT<br />

IONAL<br />

711 INFORMAT<br />

IONAL<br />

712 INFORMAT<br />

IONAL<br />

747 INFORMAT<br />

IONAL<br />

748 INFORMAT<br />

IONAL<br />

749 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The server %s sent the trap to<br />

ServerView application at station %s<br />

Pager number %d should be turned off.<br />

The server %s has changed its state to %s<br />

Remarks<br />

<strong>Trap</strong> sent from the<br />

alarm service.<br />

%s <strong>Trap</strong> sent from the<br />

alarm service.<br />

Command %d from server %s.<br />

Server %s was added.<br />

Server %s was removed.<br />

Server %s was changed.<br />

Server status %s was changed.<br />

Group (%s, %d) was added.<br />

Group (%s, %d) was removed.<br />

Group (%s, %d) was changed.<br />

Explore server %s.<br />

The Alarm Service on server %s sends a<br />

test mail.<br />

The Alarm Service on server %s tests a<br />

pager.<br />

The ServerView Alarm Service <strong>Trap</strong><br />

<strong>List</strong>en Service on server %s stops.<br />

25


26<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.5 SNI-HD-MIB (hd.mib )<br />

<strong>Trap</strong>s from FSC HD SMARTMonitoring.<br />

TRAP-TYPE/<br />

Alarm type<br />

sniSMARTFailurePredicted<br />

SMART predicted disk failure<br />

sniSMARTMonitoringDisable<br />

d<br />

SMART configuration<br />

changed<br />

table: SNI-HD-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

B.6 SNI-NT-CLUSTER-MIB (ntcluster.mib)<br />

The next table shows SNI-NT-CLUSTER-MIB traps.<br />

TRAP-TYPE/<br />

Alarm type<br />

sniWpChangeUnknown<br />

unknown notification type<br />

sniWpChangeClusterNotFoun<br />

dActive<br />

abnormal cluster status<br />

sniWpChangeClusterActiveA<br />

gain<br />

normal cluster status<br />

sniWpChangeClusterNoLonge<br />

rActive<br />

abnormal cluster status<br />

sniWpChangeNodeDeleted<br />

node deleted<br />

sniWpChangeNodeAdded<br />

node added<br />

sniWpChangeNodeState<br />

node state change<br />

sniWpChangeResourceTypeD<br />

eleted<br />

resource type deleted<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

750 CRITICAL SMART predicts failure on disk %d<br />

(%s), adapter %d (%s), on Server %s.<br />

751 INFORMAT<br />

IONAL<br />

SMART configuration has been changed<br />

on hard disk %d (%s), adapter %d (%s),<br />

on Server %s.<br />

table: SNI-NT-CLUSTER-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231)<br />

Specific<br />

Level of<br />

importance<br />

801 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The cluster has sent the unknown<br />

notification 0x%X.<br />

810 CRITICAL SNMP cannot access cluster software.<br />

<strong>Trap</strong> sent from server %s.<br />

811 INFORMAT<br />

IONAL<br />

SNMP gained access to the cluster<br />

software. <strong>Trap</strong> sent from server %s.<br />

812 CRITICAL SNMP lost access to the cluster software.<br />

<strong>Trap</strong> sent from server %s.<br />

830 INFORMAT<br />

IONAL<br />

831 INFORMAT<br />

IONAL<br />

The node %s has been deleted. ↑<br />

The node %s has been added. ↑<br />

832 MAJOR The node %s has changed its state. ↑<br />

840 INFORMAT<br />

IONAL<br />

Resource type %s has been deleted. ↑<br />

Remarks<br />

Warning predicting a<br />

disk error.<br />

Refer to "Contact<br />

Information" in<br />

"Read me First", and<br />

contact your<br />

maintenance<br />

engineer.<br />

This message appears<br />

when SMART mode<br />

has been changed.<br />

Remarks<br />

<strong>Trap</strong> from an<br />

unsupported<br />

application<br />

(ClusterView).<br />

Not displayed<br />

normally.<br />

↑<br />

↑<br />


TRAP-TYPE/<br />

Alarm type<br />

sniWpChangeResourceTypeA<br />

dded<br />

resource type created<br />

sniWpChangeGroupDeleted<br />

group deleted<br />

sniWpChangeGroupAdded<br />

group created<br />

sniWpChangeGroupState<br />

group state change<br />

sniWpChangeGroupProperty<br />

group properties change<br />

sniWpChangeResourceDeleted<br />

resource deleted<br />

sniWpChangeResourceAdded<br />

resource added<br />

sniWpChangeResourceState<br />

resource state change<br />

sniWpChangeResourcePropert<br />

y<br />

resource properties change<br />

sniWpChangeRegistryAttribut<br />

es<br />

cluster attributes change<br />

sniWpChangeRegistryKey<br />

registry namespace change<br />

sniWpChangeRegistryValue<br />

registry value change<br />

sniWpChangeNetworkDeleted<br />

network deleted<br />

sniWpChangeNetworkAdded<br />

network created<br />

sniWpChangeNetworkState<br />

network state change<br />

sniWpChangeNetworkPropert<br />

y<br />

network properties change<br />

sniWpChangeNetInterfaceDel<br />

eted<br />

network interface deleted<br />

sniWpChangeNetInterfaceAd<br />

ded<br />

network interface created<br />

sniWpChangeNetInterfaceStat<br />

e<br />

network interface state change<br />

sniWpChangeNetInterfacePro<br />

perty<br />

network interface properties<br />

change<br />

sniWpNodeUp<br />

Cluster node online<br />

table: SNI-NT-CLUSTER-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231)<br />

Specific<br />

Level of<br />

importance<br />

841 INFORMAT<br />

IONAL<br />

850 INFORMAT<br />

IONAL<br />

851 INFORMAT<br />

IONAL<br />

B.6 SNI-NT-CLUSTER-MIB (ntcluster.mib)<br />

Resource type %s has been created. ↑<br />

Group %s has been deleted. ↑<br />

Group %s has been created. ↑<br />

852 MAJOR Group %s has changed its state. ↑<br />

853 INFORMAT<br />

IONAL<br />

860 INFORMAT<br />

IONAL<br />

861 INFORMAT<br />

IONAL<br />

The properties of group %s have<br />

changed.<br />

Resource %s has been deleted. ↑<br />

Resource %s has been added. ↑<br />

862 MAJOR Resource %s has changed its state. ↑<br />

863 INFORMAT<br />

IONAL<br />

895 INFORMAT<br />

IONAL<br />

896 INFORMAT<br />

IONAL<br />

897 INFORMAT<br />

IONAL<br />

910 INFORMAT<br />

IONAL<br />

911 INFORMAT<br />

IONAL<br />

The properties of resource %s have<br />

changed.<br />

The attributes of registry key %s have<br />

been changed.<br />

Registry key %s has been created or<br />

deleted.<br />

A value of registry key %s has been<br />

changed.<br />

Network %s has been deleted. ↑<br />

Network %s has been created. ↑<br />

912 MAJOR Network %s has changed its state. ↑<br />

913 INFORMAT<br />

IONAL<br />

920 INFORMAT<br />

IONAL<br />

921 INFORMAT<br />

IONAL<br />

The properties of Network %s have<br />

changed.<br />

Network interface %s has been deleted. ↑<br />

Network interface %s has been created. ↑<br />

922 MAJOR Network interface %s has changed its<br />

state.<br />

923 INFORMAT<br />

IONAL<br />

924 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The properties of network interface %s<br />

have changed.<br />

Cluster node %s is online. ↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks<br />

27


28<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

sniWpNodeDown<br />

Cluster node offline<br />

sniWpNodePaused<br />

Cluster node paused<br />

sniWpNodeJoining<br />

Cluster node joining<br />

sniWpGroupOnline<br />

Cluster group online<br />

sniWpGroupPartialOnline<br />

Cluster group partially online<br />

sniWpGroupPending<br />

Cluster group pending<br />

sniWpGroupOffline<br />

Cluster group offline<br />

sniWpGroupFailed<br />

Cluster group failed<br />

sniWpResourceOnline<br />

Cluster resource online<br />

sniWpResourceOffline<br />

Cluster resource offline<br />

sniWpResourceFailed<br />

Cluster resource failed<br />

sniWpNetworkUp<br />

Network reactivated<br />

sniWpNetworkDown<br />

Cluster network down<br />

sniWpNetworkUnavailable<br />

Cluster network unavailable<br />

sniWpNetInterfaceUp<br />

Cluster network interface<br />

reactivated<br />

sniWpNetInterfaceFailed<br />

Cluster network interface<br />

failed<br />

sniWpNetInterfaceUnreachable<br />

Cluster network interface<br />

unreachable<br />

sniWpNetInterfaceUnavailable<br />

Cluster network interface<br />

unavailable<br />

table: SNI-NT-CLUSTER-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231)<br />

Specific<br />

Level of<br />

importance<br />

925 INFORMAT<br />

IONAL<br />

926 INFORMAT<br />

IONAL<br />

927 INFORMAT<br />

IONAL<br />

928 INFORMAT<br />

IONAL<br />

929 INFORMAT<br />

IONAL<br />

930 INFORMAT<br />

IONAL<br />

931 INFORMAT<br />

IONAL<br />

Cluster node %s is offline. ↑<br />

Cluster node %s has been paused. ↑<br />

Cluster node %s is joining. ↑<br />

Cluster group %s is online. ↑<br />

Cluster group %s is partially online. ↑<br />

Cluster group %s is pending. ↑<br />

Cluster group %s is offline. ↑<br />

932 MAJOR Cluster group %s has failed. ↑<br />

933 INFORMAT<br />

IONAL<br />

934 INFORMAT<br />

IONAL<br />

Cluster resource %s is online. ↑<br />

Cluster resource %s is offline. ↑<br />

935 MAJOR Cluster resource %s has failed. ↑<br />

936 INFORMAT<br />

IONAL<br />

937 INFORMAT<br />

IONAL<br />

Cluster network %s reactivated. ↑<br />

Cluster network %s down. ↑<br />

938 MAJOR Cluster network %s unavailable. ↑<br />

939 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Cluster network interface %s reactivated. ↑<br />

940 MAJOR Cluster network interface %s has failed. ↑<br />

941 MAJOR Cluster network interface %s unreachable. ↑<br />

942 MAJOR Cluster network interface %s unavailable. ↑<br />

Remarks


B.7 PCI-HOTPLUG-MIB (pcihotplug.mib)<br />

<strong>Trap</strong>s from PCI HOTPLUG.<br />

TRAP-TYPE/<br />

Alarm type<br />

siePciHotPlug<strong>Trap</strong>HotRemoval<br />

Start of HotPlug action<br />

siePciHotPlug<strong>Trap</strong>HotReplace<br />

Start of HotPlug action<br />

siePciHotPlug<strong>Trap</strong>EndHotPlu<br />

gAction<br />

End of HotPlug action<br />

sieDeviceHotPlug<strong>Trap</strong>HotRe<br />

moval<br />

Device HotPlug action<br />

sieDeviceHotPlug<strong>Trap</strong>HotRep<br />

lace<br />

Device HotPlug action<br />

sieDeviceHotPlug<strong>Trap</strong>HotAdd<br />

Device HotPlug action<br />

table: PCI-HOTPLUG-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

1000 INFORMAT<br />

IONAL<br />

B.8 SERVERVIEW-STATUS-MIB (status.mib)<br />

<strong>Trap</strong>s from the ServerView status agent.<br />

TRAP-TYPE/<br />

Alarm type<br />

sieSt<strong>Trap</strong>StatusChanged<br />

Status changed<br />

1001 INFORMAT<br />

IONAL<br />

B.9 SIEMENS-MULTIPATH-MIB (mp.mib)<br />

<strong>Trap</strong>s from FSC MultiPath SNMP agent's.<br />

TRAP-TYPE/<br />

Alarm type<br />

sieMPError<br />

MP: Last port failed<br />

1002 INFORMAT<br />

IONAL<br />

1020 INFORMAT<br />

IONAL<br />

1021 INFORMAT<br />

IONAL<br />

1022 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A Hot Removal action is started on<br />

physical slot %d (server %s).<br />

A Hot Replace action is started on<br />

physical slot %d (Server %s).<br />

The HotPlug action on physical slot %d<br />

is terminated %s (Server %s). The card<br />

state is : %s<br />

A SCSI device on SCSI adapter<br />

(PCI Bus Number %d, Device<br />

Number %d) has been removed (server<br />

%s).<br />

A SCSI device on SCSI adapter<br />

(PCI Bus Number %d, Device<br />

Number %d) has been replaced (server<br />

%s).<br />

A SCSI device on SCSI adapter<br />

(PCI Bus Number %d, Device<br />

Number %d) has been added (server %s).<br />

B.7 PCI-HOTPLUG-MIB (pcihotplug.mib)<br />

table: SERVERVIEW-STATUS-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

1100 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks<br />

<strong>Trap</strong> from an<br />

unsupported<br />

application<br />

(ClusterView).<br />

Not displayed<br />

normally.<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks<br />

System status has changed at server %s. Check the previous and<br />

subsequent <strong>Trap</strong>s.<br />

table: SIEMENS-MULTIPATH-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1200 CRITICAL MultiPath group %d on server %s is<br />

down.<br />

Remarks<br />

29


30<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

sieMPRetry<br />

MP: Port failed<br />

sieMPActivePortChanged<br />

MP: Port activated<br />

sieMPReconfigured<br />

MP: Port added/removed<br />

sieMPStatusChanged<br />

MP: Behavior changed<br />

sieMPAutoRecovered<br />

MP: Port alive again<br />

sieMPErrorCleared<br />

MP: Status cleared<br />

1201 MAJOR Port %d of MultiPath group %d on server<br />

%s is down. Error on ID %d, Lun %d.<br />

1202 INFORMAT<br />

IONAL<br />

1203 INFORMAT<br />

IONAL<br />

1204 INFORMAT<br />

IONAL<br />

1205 INFORMAT<br />

IONAL<br />

1206 INFORMAT<br />

IONAL<br />

Active port for MultiPath group %d<br />

changed on server %s. Port %d is now<br />

active port.<br />

MultiPath group %d reconfigured on<br />

server %s. Port %d was affected.<br />

MultiPath behavior for group %d was<br />

changed on server %s.<br />

MultiPath group %d on server %s: Port<br />

%d recovered from error.<br />

MultiPath group %d on server %s: Error<br />

for MultiPath port %d was cleared.<br />

B.10 SERVERVIEW-DUPLEXDATAMANAGER-MIB<br />

(ddm.mib)<br />

<strong>Trap</strong>s from DuplexDataManage. Refer to the S60 manual for details.<br />

table: SERVERVIEW-DUPLEXDATAMANAGER-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

TRAP-TYPE/<br />

Alarm type<br />

fscDdmNewConfig<br />

DDM: New DuplexWrite<br />

configuration<br />

fscDdmPieceRemoved<br />

DDM: DuplexWrite piece<br />

removed<br />

fscDdmConfigRemoved<br />

DDM: DuplexWrite<br />

configuration removed<br />

fscDdmStatusSet<br />

DDM: DuplexWrite status<br />

changed<br />

fscDdmUpdateStatus<br />

DDM: DuplexWrite status<br />

updated<br />

fscDdmPieceRecovered<br />

DDM: DuplexWrite piece<br />

recovered<br />

fscDdmRecoverAborted<br />

DDM: Recover aborted<br />

fscDdmReservationConflict<br />

DDM: reservation conflict<br />

fscDdmConfigChanged<br />

DDM: DuplexWrite<br />

configuration changed<br />

table: SIEMENS-MULTIPATH-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

Specific<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

1400 INFORMAT<br />

IONAL<br />

1401 INFORMAT<br />

IONAL<br />

1402 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Configuration for DuplexWrite group<br />

%d/%d/%d/%d was created or updated<br />

on server %s.<br />

DuplexWrite piece %d/%d/%d/%d was<br />

removed from group on server %s.<br />

DuplexWrite group %d/%d/%d/%d was<br />

removed on server %s.<br />

1403 MINOR Status of DuplexWrite piece %d/%d/%d/<br />

%d on server %s has changed (user<br />

request).<br />

1404 MINOR Status of DuplexWrite piece %d/%d/%d/<br />

%d on server %s has changed (driver<br />

request).<br />

1405 INFORMAT<br />

IONAL<br />

DuplexWrite piece %d/%d/%d/%d<br />

successfully recovered on server %s.<br />

1406 MINOR DuplexWrite piece %d/%d/%d/%d<br />

aborted Recover process on server %s.<br />

1407 INFORMAT<br />

IONAL<br />

1408 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Reservation conflict occured on<br />

DuplexWrite group %d/%d/%d/%d on<br />

server %s - group is not accessible.<br />

DuplexWrite has found a new<br />

configuration on server %s.<br />

Remarks<br />

Remarks


fscDdmConfigInvalidated<br />

DDM: DuplexWrite<br />

configuration invalidated<br />

fscDdmActiveLunChanged<br />

DDM: Active DuplexWrite<br />

piece changed<br />

fscDdmPieceFailed<br />

DDM: DuplexWrite piece<br />

failed<br />

fscDdmRootFlagChanged<br />

DDM: RootDisk flag changed<br />

fscDdmForceActive<br />

DDM: DuplexWrite piece<br />

forced active<br />

fscDdmNameChanged<br />

DDM: DuplexWrite name<br />

changed<br />

fscDdmPathFailed<br />

DDM: MultiPath path failed<br />

fscDdmRetry<br />

DDM: MultiPath path retried<br />

fscDdmActivePortChanged<br />

DDM: Active MultiPath path<br />

changed<br />

fscDdmReconfigured<br />

DDM: MultiPath reconfigured<br />

fscDdmStatusChanged<br />

DDM: MultiPath status<br />

changed<br />

fscDdmAutoRecovered<br />

DDM: MultiPath path<br />

AutoRecovered<br />

fscDdmErrorCleared<br />

DDM: MultiPath path error<br />

cleared<br />

fscDdmPnPRemove<br />

DDM: PnP Removal<br />

fscDdmPnPNew<br />

DDM: PnP Add<br />

fscDdmCluster<br />

DDM: Cluster configuration<br />

changed<br />

1409 INFORMAT<br />

IONAL<br />

1410 INFORMAT<br />

IONAL<br />

B.10 SERVERVIEW-DUPLEXDATAMANAGER-MIB (ddm.mib)<br />

table: SERVERVIEW-DUPLEXDATAMANAGER-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2)<br />

TRAP-TYPE/<br />

Alarm type<br />

Specific<br />

Level of<br />

importance<br />

Configuration information was<br />

invalidated for DuplexWrite group %d/<br />

%d/%d/%d on server %s.<br />

DuplexWrite piece %d/%d/%d/%d is<br />

used for read commands on server %s.<br />

1411 CRITICAL DuplexWrite piece %d/%d/%d/%d failed<br />

on server %s.<br />

1412 INFORMAT<br />

IONAL<br />

1413 INFORMAT<br />

IONAL<br />

1414 INFORMAT<br />

IONAL<br />

RootDisk flag changed on DuplexWrite<br />

group %d/%d/%d/%d on server %s.<br />

DuplexWrite piece %d/%d/%d/%d<br />

marked forced active on server %s<br />

(Snapshot).<br />

Name of DuplexWrite group %d/%d/%d/<br />

%d has changed on server %s.<br />

1415 CRITICAL MultiPath path %d/%d/%d/%d failed on<br />

server %s.<br />

1416 MAJOR MultiPath path %d/%d/%d/%d failed on<br />

server %s - retry successful on other port.<br />

1417 INFORMAT<br />

IONAL<br />

1418 INFORMAT<br />

IONAL<br />

1419 INFORMAT<br />

IONAL<br />

1420 INFORMAT<br />

IONAL<br />

1421 INFORMAT<br />

IONAL<br />

1422 INFORMAT<br />

IONAL<br />

1423 INFORMAT<br />

IONAL<br />

1424 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

MultiPath path %d/%d/%d/%d is active<br />

on server %s.<br />

MultiPath configuration changed on<br />

server %s.<br />

Status of MultiPath path %d/%d/%d/%d<br />

has changed on server %s.<br />

MultiPath path %d/%d/%d/%d<br />

automatically recovered on server %s.<br />

Error cleared on MultiPath path %d/%d/<br />

%d/%d on server %s.<br />

Plug and Play Removal occured on<br />

server %s.<br />

Plug and Play Add occured on server %s.<br />

Cluster configuration changed on server<br />

%s.<br />

Remarks<br />

31


32<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.11 FSC-SERVERCONTROL2-MIB (sc2.mib)<br />

sc2<strong>Trap</strong>Test<br />

Test trap<br />

<strong>Trap</strong>s from the ServerView agent.<br />

table: FSC-SERVERCONTROL2-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2.2.10.20)<br />

TRAP-TYPE/<br />

Alarm type<br />

sc2<strong>Trap</strong>CommunicationFailure<br />

Communication lost<br />

sc2<strong>Trap</strong>CommunicationEstablished<br />

Communication established<br />

sc2<strong>Trap</strong>ControllerSelftestWarning<br />

Controller selftest warning<br />

sc2<strong>Trap</strong>ControllerSelftestError<br />

Controller selftest error<br />

sc2<strong>Trap</strong>BiosSelftestError<br />

Critical BIOS selftest error<br />

sc2<strong>Trap</strong>FanAdded<br />

Fan added<br />

sc2<strong>Trap</strong>FanRemoved<br />

Fan removed<br />

sc2<strong>Trap</strong>FanOk<br />

Fan OK<br />

sc2<strong>Trap</strong>FanCritical<br />

Fan failure predicted<br />

sc2<strong>Trap</strong>FanFailed<br />

Fan failed<br />

sc2<strong>Trap</strong>RedundantFanFailed<br />

Redundant fan failed<br />

sc2<strong>Trap</strong>TempOk<br />

Temperature normal<br />

sc2<strong>Trap</strong>TempWarning<br />

Temperature warning<br />

sc2<strong>Trap</strong>TempCritical<br />

Temperature critical<br />

sc2<strong>Trap</strong>TempSensorOk<br />

Temperature sensor OK<br />

sc2<strong>Trap</strong>TempSensorBroken<br />

Temperature sensor broken<br />

sc2<strong>Trap</strong>PowerSupplyAdded<br />

Power supply added<br />

sc2<strong>Trap</strong>PowerSupplyRemoved<br />

Power supply removed<br />

Specific<br />

Level of<br />

importance<br />

2000 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Test trap from server %s (no error).<br />

2001 MINOR Communication with the Server<br />

Management controller in cabinet %d of<br />

server %s lost.<br />

2002 INFORMAT<br />

IONAL<br />

Communication with the Server<br />

Management controller in cabinet %d of<br />

server %s established again.<br />

2003 MINOR The Server Management controller in<br />

cabinet %d has detected an minor<br />

problem during selftest of server %s.<br />

2004 CRITICAL The Server Management controller in<br />

cabinet %d of server %s failed.<br />

2005 CRITICAL A critical error happend while BIOS<br />

selftest in cabinet %d of server %s. See<br />

server management message log<br />

(recovery log) for detailed information.<br />

2010 INFORMAT<br />

IONAL<br />

2011 INFORMAT<br />

IONAL<br />

2012 INFORMAT<br />

IONAL<br />

Fan %s was added into cabinet %d of<br />

server %s.<br />

Fan %s was removed from cabinet %d of<br />

server %s.<br />

Fan %s in cabinet %d of server %s is<br />

working again.<br />

2013 MAJOR Fan %s will fail in near future in cabinet<br />

%d of server %s.<br />

2014 CRITICAL Fan %s failed in cabinet %d of server %s.<br />

2015 MAJOR The redundant fan %s failed in cabinet<br />

%d of server %s. System can become<br />

critical if another fan in this group fails.<br />

2020 INFORMAT<br />

IONAL<br />

Temperature at sensor %s in cabinet %d<br />

of server %s is within normal range.<br />

2021 MAJOR Temperature at sensor %s in cabinet %d<br />

of server %s has reached the warning<br />

level.<br />

2022 CRITICAL Temperature at sensor %s in cabinet %d<br />

of server %s has reached the critical<br />

level.<br />

2023 INFORMAT<br />

IONAL<br />

Temperature sensor %s in cabinet %d of<br />

server %s is working again.<br />

2024 MAJOR Temperature sensor %s in cabinet %d of<br />

server %s is broken or not connected.<br />

2030 INFORMAT<br />

IONAL<br />

2031 INFORMAT<br />

IONAL<br />

Power supply %s in cabinet %d at server<br />

%s was added.<br />

Power supply %s in cabinet %d at server<br />

%s was removed.<br />

Remarks


sc2<strong>Trap</strong>PowerSupplyOk<br />

Power supply OK<br />

sc2<strong>Trap</strong>PowerSupplyCritical<br />

Power supply critical<br />

sc2<strong>Trap</strong>PowerSupplyFailed<br />

Power supply failed<br />

sc2<strong>Trap</strong>RedundantPowerSupplyFailed<br />

Redundant power supply failed<br />

sc2<strong>Trap</strong>PowerSupplyRedundancyLost<br />

Power supply redundancy lost<br />

sc2<strong>Trap</strong>AcFail<br />

AC failed<br />

sc2<strong>Trap</strong>DcFail<br />

Power failed<br />

sc2<strong>Trap</strong>OnBattery<br />

AC failed, on battery<br />

sc2<strong>Trap</strong>OnMains<br />

AC OK<br />

sc2<strong>Trap</strong>VoltageOk<br />

Voltage OK<br />

2032 INFORMAT<br />

IONAL<br />

B.11 FSC-SERVERCONTROL2-MIB (sc2.mib)<br />

table: FSC-SERVERCONTROL2-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2.2.10.20)<br />

TRAP-TYPE/<br />

Alarm type<br />

sc2<strong>Trap</strong>VoltageTooLow<br />

Voltage too low<br />

sc2<strong>Trap</strong>VoltageTooHigh<br />

Voltage too high<br />

sc2<strong>Trap</strong>VoltageFailed<br />

Voltage out of range<br />

sc2<strong>Trap</strong>BatteryVoltagePrefail<br />

Battery failure predicted<br />

sc2<strong>Trap</strong>CorrectableMemErrorAddr<br />

Correctable memory error<br />

sc2<strong>Trap</strong>UncorrectableMemErrorAddr<br />

Uncorrectable memory error<br />

sc2<strong>Trap</strong>CorrectableMemErrorBank<br />

Correctable memory error<br />

sc2<strong>Trap</strong>UncorrectableMemErrorBank<br />

Uncorrectable memory error<br />

sc2<strong>Trap</strong>CorrectableMemErrorModule<br />

Correctable memory error<br />

sc2<strong>Trap</strong>UncorrectableMemErrorModule<br />

Uncorrectable memory error<br />

sc2<strong>Trap</strong>CorrectableMemError<br />

Correctable memory error<br />

sc2<strong>Trap</strong>UncorrectableMemError<br />

Uncorrectable memory error<br />

Specific<br />

Level of<br />

importance<br />

Power supply %s in cabinet %d at server<br />

%s is working again.<br />

2033 CRITICAL Insufficiant operating power supplies<br />

available in cabinet %d at server %s.<br />

2034 MAJOR Power supply %s in cabinet %d at server %s<br />

failed.<br />

2035 MAJOR Redundant power supply %s in cabinet<br />

%d at server %s failed. System can<br />

become critical if another power supply<br />

fails.<br />

2036 MINOR Power supply redundancy in cabinet %d<br />

at server %s lost. System will become<br />

critical if a power supply fails.<br />

2040 CRITICAL AC failure in cabinet %d of server %s.<br />

2041 CRITICAL DC power failure in cabinet %d of server<br />

%s.<br />

2042 CRITICAL AC failure. Cabinet %d is running on<br />

battery power since %d seconds. In %d<br />

minutes server %s will shutdown.<br />

2043 INFORMAT<br />

IONAL<br />

2050 INFORMAT<br />

IONAL<br />

Mains returned after power failure in<br />

cabinet %d at server %s.<br />

Power supply voltage %s in cabinet %d<br />

at server %s is within normal range<br />

again.<br />

2051 CRITICAL Power supply voltage %s in cabinet %d<br />

at server %s is too low.<br />

2052 CRITICAL Power supply voltage %s in cabinet %d<br />

at server %s is too high.<br />

2053 CRITICAL Power supply voltage %s in cabinet %d<br />

at server %s is out of range¥.<br />

2054 MAJOR Battery voltage %s in cabinet %d at<br />

server %s: Battery is predicted to fail in<br />

near future.<br />

2060 INFORMAT<br />

IONAL<br />

Correctable memory error at address %d<br />

in cabinet %d of server %s.<br />

2061 CRITICAL Uncorrectable memory error at address<br />

%d in cabinet %d of server %s.<br />

2062 INFORMAT<br />

IONAL<br />

Correctable memory error at bank %s in<br />

cabinet %d of server %s.<br />

2063 CRITICAL Uncorrectable memory error at bank %s<br />

in cabinet %d of server %s.<br />

2064 INFORMAT<br />

IONAL<br />

Correctable memory error at module %s<br />

in cabinet %d of server %s.<br />

2065 CRITICAL Uncorrectable memory error at module<br />

%s in cabinet %d of server %s.<br />

2066 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Correctable memory error in cabinet %d<br />

of server %s.<br />

2067 CRITICAL Uncorrectable memory error in cabinet<br />

%d of server %s.<br />

Remarks<br />

33


34<br />

B <strong>Trap</strong> <strong>List</strong><br />

table: FSC-SERVERCONTROL2-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.2.2.10.20)<br />

TRAP-TYPE/<br />

Alarm type<br />

sc2<strong>Trap</strong>MemErrorModulePrefail<br />

Memory module prefailure<br />

sc2<strong>Trap</strong>MemErrorModuleFailing<br />

Memory module failing<br />

sc2<strong>Trap</strong>MemErrorModuleReplaced<br />

Memory module replaced<br />

sc2<strong>Trap</strong>CpuSpeedChanged<br />

CPU speed changed<br />

sc2<strong>Trap</strong>CpuPrefail<br />

CPU prefailure<br />

sc2<strong>Trap</strong>CabinetSwitchedOff<br />

Cabinet switched off<br />

sc2<strong>Trap</strong>CabinetSwitchedOn<br />

Cabinet switched on<br />

sc2<strong>Trap</strong>PowerOffTimeReached<br />

Power off time reached<br />

sc2<strong>Trap</strong>ServerShutdown<br />

Server shutdown<br />

sc2<strong>Trap</strong>ShutdownCancelled<br />

Shutdown cancelled<br />

sc2<strong>Trap</strong>BootRetryCountZero<br />

Boot retry counter zero<br />

sc2<strong>Trap</strong>MessageLogFull<br />

Message log full<br />

sc2<strong>Trap</strong>MessageLogWarning<br />

Message log warning<br />

sc2<strong>Trap</strong>BootMessageLogEntry<br />

Error in message log<br />

sc2<strong>Trap</strong>IntrusionAssertion<br />

Front door or housing opened<br />

sc2<strong>Trap</strong>IntrusionDeassertion<br />

Front door or housing closed<br />

sc2<strong>Trap</strong>IntrusionChanged<br />

Front door or housing opened/closed<br />

Specific<br />

Level of<br />

importance<br />

2068 MAJOR Memory module failure is predicted for<br />

module %s in cabinet %d of server %s.<br />

2069 MAJOR Memory module %s in cabinet %d of<br />

server %s is failing. Too many errors<br />

have occured.<br />

2070 MAJOR Memory module module %s in cabinet<br />

%d of server %s had failed and was<br />

replaced by a hot-spare module<br />

2080 INFORMAT<br />

IONAL<br />

CPU speed at server %s changed to %d<br />

percent of its maximum speed.<br />

2081 MAJOR CPU failure is predicted for CPU %s in<br />

cabinet %d of server %s.<br />

2090 INFORMAT<br />

IONAL<br />

2091 INFORMAT<br />

IONAL<br />

2092 INFORMAT<br />

IONAL<br />

2093 INFORMAT<br />

IONAL<br />

2094 INFORMAT<br />

IONAL<br />

Cabinet %d was switched off because of<br />

%s (server %s).<br />

Cabinet %d was switched on because of<br />

%s (server %s).<br />

The power-off time is reached in cabinet<br />

%d on server %s! System shutdown in<br />

%d minutes.<br />

The reason %s causes a shutdown at<br />

server %s.<br />

Shutdown at server %s cancelled by the<br />

user.<br />

2095 MAJOR Boot retry counter is zero on server %s.<br />

2100 MINOR The System Event Log on server %s in<br />

cabinet %d is full. No more messages can<br />

be logged! Please clear unneeded log<br />

entries as soon as possible!<br />

2101 MINOR The System Event Log for cabinet %d at<br />

server %s has exceeded %d%% of its<br />

capacity.<br />

2102 MAJOR An error was recorded on server %s<br />

before the management agents were<br />

started (boot phase).<br />

See server management message log<br />

(Recovery log) for detailed information.<br />

2110 MAJOR The front door or housing of cabinet %d<br />

was opened on server %s.<br />

2111 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The front door or housing of cabinet %d<br />

was closed on server %s.<br />

2112 MAJOR The front door or housing of cabinet %d<br />

was opened or closed on server %s.<br />

Remarks


B.12 BLADE-MIB (S31.mib)<br />

<strong>Trap</strong>s from blade server (BX300/BX600). Refer to the blade server manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

s31Test<strong>Trap</strong><br />

Test trap<br />

s31MgmtBladeAdded<br />

Management blade added<br />

s31MgmtBladeRemoved<br />

Management blade removed<br />

s31MgmtBladeOk<br />

Status of management blade is<br />

OK<br />

s31MgmtBladeError<br />

Status of management blade is<br />

error<br />

s31MgmtBladeCriticalError<br />

Status of management blade is<br />

critical<br />

s31ServerBladeAdded<br />

Server blade added<br />

s31ServerBladeRemoved<br />

Server blade removed<br />

s31ServerBladeOk<br />

Status of server blade is OK<br />

s31ServerBladeError<br />

Status of server blade is error<br />

s31ServerBladeCriticalError<br />

Status of server blade is<br />

critical<br />

s31SwitchBladeAdded<br />

Switch blade added<br />

s31SwitchBladeRemoved<br />

Switch blade removed<br />

s31SwitchBladeOk<br />

Status of switch blade is OK<br />

s31SwitchBladeError<br />

Status of switch blade is error<br />

s31SwitchBladeCriticalError<br />

Status of switch blade is<br />

critical<br />

s31SysFanAdded<br />

System fan added<br />

s31SysFanRemoved<br />

System fan removed<br />

s31SysFanOk<br />

Status of system fan is OK<br />

s31SysFanError<br />

Status of system fan is error<br />

s31SysFanCriticalError<br />

Status of system fan is critical<br />

table: BLADE-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7244.1.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1600 INFORMAT<br />

IONAL<br />

1601 INFORMAT<br />

IONAL<br />

1602 INFORMAT<br />

IONAL<br />

1603 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Test trap from blade chassis %s (no<br />

error).<br />

Management blade %d at blade chassis<br />

%s was added.<br />

Management blade %d at blade chassis<br />

%s was removed.<br />

Management blade %d at blade chassis<br />

%s status is ok.<br />

1604 MAJOR Management blade %d at blade chassis<br />

%s status is error.<br />

1605 CRITICAL Management blade %d at blade chassis<br />

%s status is critical.<br />

1606 INFORMAT<br />

IONAL<br />

1607 INFORMAT<br />

IONAL<br />

1608 INFORMAT<br />

IONAL<br />

Server blade %d at blade chassis %s was<br />

added.<br />

Server blade %d at blade chassis %s was<br />

removed.<br />

Server blade %d at blade chassis %s<br />

status is OK.<br />

1609 MAJOR Server blade %d at blade chassis %s status<br />

is error.<br />

1610 CRITICAL Server blade %d at blade chassis %s<br />

status is critical.<br />

1611 INFORMAT<br />

IONAL<br />

1612 INFORMAT<br />

IONAL<br />

1613 INFORMAT<br />

IONAL<br />

Switch blade %d at blade chassis %s was<br />

added.<br />

Switch blade %d at blade chassis %s was<br />

removed.<br />

Switch blade %d at blade chassis %s<br />

status is OK.<br />

1614 MAJOR Switch blade %d at blade chassis %s<br />

status is error.<br />

1615 CRITICAL Switch blade %d at blade chassis %s<br />

status is critical.<br />

1616 INFORMAT<br />

IONAL<br />

1617 INFORMAT<br />

IONAL<br />

1618 INFORMAT<br />

IONAL<br />

System fan %d at blade chassis %s was<br />

added.<br />

System fan %d at blade chassis %s was<br />

removed.<br />

System fan %d at blade chassis %s status<br />

is OK.<br />

1619 MAJOR System fan %d at blade chassis %s status<br />

is error.<br />

1620 CRITICAL System fan %d at blade chassis %s status<br />

is critical.<br />

B.12 BLADE-MIB (S31.mib)<br />

Remarks<br />

35


36<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

s31SysTempOk<br />

Temperature normal<br />

s31SysTempError<br />

Temperature abnormal<br />

s31SysTempCriticalError<br />

Temperature critical<br />

s31SysTempSensorOk<br />

System temperature sensor<br />

OK<br />

s31SysTempSensorBroken<br />

System temperature sensor<br />

broken<br />

s31SysPowerSupplyAdded<br />

Power supply added<br />

s31SysPowerSupplyRemoved<br />

Power supply removed<br />

s31SysPowerSupplyOk<br />

Power supply OK<br />

s31SysPowerSupplyError<br />

Power supply failed<br />

s31SysPowerSupplyCriticalEr<br />

ror<br />

Power supply critical<br />

s31ServerPowerOn<br />

Power on<br />

s31ServerPostError<br />

Post error<br />

s31ServerBootError<br />

Boot error<br />

s31ServerShutdown<br />

Server shutdown<br />

s31ServerSoftwareWatchdogE<br />

xpired<br />

Software watchdog expired<br />

s31ServerBootWatchdogExpir<br />

ed<br />

Boot watchdog expired<br />

s31UserAuthenticationFailure<br />

User authentication failure<br />

s31<strong>Trap</strong>EventLog<br />

Error in event log<br />

s31ServerBladeNewAdd<br />

Server blade was added on a<br />

empty slot<br />

table: BLADE-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7244.1.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1621 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Temperature at system temperature sensor<br />

%d of blade chassis %s is within normal<br />

range.<br />

1622 MAJOR Temperature at system temperature<br />

sensor %d of blade chassis %s is out of<br />

normal range.<br />

1623 CRITICAL Temperature at system temperature<br />

sensor %d of blade chassis %s has<br />

reached the critical level.<br />

1624 INFORMAT<br />

IONAL<br />

System temperature sensor %d of blade<br />

chassis %s is working again.<br />

1625 MAJOR System temperature sensor %d of blade<br />

chassis %s is broken or not connected.<br />

1626 INFORMAT<br />

IONAL<br />

1627 INFORMAT<br />

IONAL<br />

1628 INFORMAT<br />

IONAL<br />

Power supply unit %d at blade chassis<br />

%s was added.<br />

Power supply unit %d at blade chassis<br />

%s was removed.<br />

Power supply unit %d at blade chassis<br />

%s is working again.<br />

1629 MAJOR Power supply unit %d at blade chassis<br />

%s failed.<br />

1630 CRITICAL Insufficiant operating power supplies unit<br />

available in power supply unit %d at<br />

blade chassis %s.<br />

1631 INFORMAT<br />

IONAL<br />

1632 INFORMAT<br />

IONAL<br />

1633 INFORMAT<br />

IONAL<br />

1634 INFORMAT<br />

IONAL<br />

1635 INFORMAT<br />

IONAL<br />

1636 INFORMAT<br />

IONAL<br />

Server blade %d at blade chassis %s is<br />

powered on.<br />

Server blade %d at blade chassis %s is<br />

posted error.<br />

No bootable operation system found at<br />

server blade %d of blade chassis %s.<br />

Server blade %d at blade chassis %s is<br />

shutdowned.<br />

Software watchdog at server blade %d of<br />

blade chassis %s expired.<br />

Boot watchdog at server blade %d of<br />

blade chassis %s expired.<br />

1637 MAJOR User authentication failure detected at<br />

blade chassis %s, performing protocol<br />

%s.<br />

1638 MAJOR An error was recorded on blade chassis<br />

%s. See server management event error<br />

log (Recovery) for detailed information.<br />

1639 INFORMAT<br />

IONAL<br />

Server blade %d at blade chassis %s is<br />

added on a empty slot.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

s31ServerBladeHotReplace<br />

Server blade was added on a<br />

marked for hot replacement<br />

slot<br />

s31ServerPowerOff<br />

Power off<br />

s31SysTempSensorAdded<br />

System temperature sensor<br />

added<br />

s31SysTempSensorRemoved<br />

System temperature sensor<br />

removed<br />

s31LivetimeError<br />

System live time has exceeded<br />

the limited count<br />

s31PowerOverBudget<br />

Server blade power on failed<br />

s31NicDetectionFail<br />

Nic detection failed<br />

s31SysPowerSupplyOvpFail<br />

Power supply OVP fail<br />

s31SysPowerSupplyOcpFail<br />

Power supply OCP fail<br />

s31FiberChannelAdded<br />

Fiber channel pass through<br />

card added<br />

s31FiberChannelRemoved<br />

Fiber channel pass through<br />

card removed<br />

s31SysPowerSupplyOverallSt<br />

atusOk<br />

System power supply overall<br />

status<br />

s31SysPowerSupplyOverallSt<br />

atusDegraded<br />

System power supply overall<br />

status<br />

s31SysPowerSupplyOverallSt<br />

atusCritical<br />

System power supply overall<br />

status<br />

s31SysFanOverallStatusOk<br />

System fan overall status<br />

s31SysFanOverallStatusDegra<br />

ded<br />

System fan overall status<br />

s31SysFanOverallStatusCritic<br />

al<br />

System fan overall status<br />

table: BLADE-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7244.1.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1640 INFORMAT<br />

IONAL<br />

1641 INFORMAT<br />

IONAL<br />

1642 INFORMAT<br />

IONAL<br />

1643 INFORMAT<br />

IONAL<br />

1644 INFORMAT<br />

IONAL<br />

1645 INFORMAT<br />

IONAL<br />

1646 INFORMAT<br />

IONAL<br />

1647 INFORMAT<br />

IONAL<br />

1648 INFORMAT<br />

IONAL<br />

1649 INFORMAT<br />

IONAL<br />

1650 INFORMAT<br />

IONAL<br />

1651 INFORMAT<br />

IONAL<br />

1652 INFORMAT<br />

IONAL<br />

1653 INFORMAT<br />

IONAL<br />

1654 INFORMAT<br />

IONAL<br />

1655 INFORMAT<br />

IONAL<br />

1656 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Server blade %d at blade chassis %s is<br />

added on a marked for hot replacement<br />

slot.<br />

Server blade %d at blade chassis %s is<br />

powered off.<br />

System temperature sensor %d of blade<br />

chassis %s is added.<br />

System temperature sensor %d of blade<br />

chassis %s is removed.<br />

Server %s live time has exceeded the<br />

limited count.<br />

Server blade %d at blade chassis %s<br />

power on failed because of over power<br />

budget.<br />

Management blade %d at blade chassis<br />

%s NIC detection failed.<br />

Power supply unit %d OVP fail.<br />

Power supply unit %d OCP fail.<br />

Fiber channel pass through card %d at<br />

blade chassis %s was added.<br />

Fiber channel pass through card %d at<br />

blade chassis %s was removed.<br />

System power supply overall status = OK<br />

System power supply overall status =<br />

degraded<br />

System power supply overall status =<br />

critical<br />

System fan overall status = OK<br />

System fan overall status = degraded<br />

system fan overall status = critical<br />

B.12 BLADE-MIB (S31.mib)<br />

Remarks<br />

37


38<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

s31SysTemperatureOverallSta<br />

tusOk<br />

System temperature overall<br />

status<br />

s31SysTemperatureOverallSta<br />

tusDegraded<br />

System temperature overall<br />

status<br />

s31SysTemperatureOverallSta<br />

tusCritical<br />

System temperature overall<br />

status<br />

1657 INFORMAT<br />

IONAL<br />

1658 INFORMAT<br />

IONAL<br />

1659 INFORMAT<br />

IONAL<br />

System temperature overall status = OK<br />

System temperature overall status =<br />

degraded<br />

System temperature overall status =<br />

critical<br />

B.13 AdaptecArrayController-MIB (aac.mib)<br />

<strong>Trap</strong>s from blade server (PRIMERGY BX600) HostRAID Adaptec Array Controller. Refer to the blade<br />

server manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

aacDriveLetterChange<br />

A Drive Letter Changed<br />

aacFailoverChange<br />

A change in failover<br />

assignments occurred<br />

aacContainerStateChange<br />

A container changed its state<br />

aacFileSystemChange<br />

A file system change has<br />

occurred<br />

aacGeneralContainerFailure<br />

An unknown error occurred on<br />

container<br />

aacMirrorNotMirroring<br />

Container no longer mirroring<br />

aacMirrorFailureNoSpace<br />

Not enough failover space for<br />

mirror<br />

aacMirrorFailureNoUnmirror<br />

Container could not be<br />

unmirrored<br />

aacMirrorFailoverStarted<br />

Mirror failover started<br />

aacMirrorFailoverFailed<br />

Mirror failover failed<br />

aacMirrorNoFailoverAssigned<br />

No failover for mirror<br />

table: BLADE-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7244.1.1.1)<br />

Specific<br />

table: AdaptecArrayController-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.10.1.1)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A Drive Letter Changed on controller %s<br />

for container %d.<br />

A change in failover assignments<br />

occurred on controller %s.<br />

3 MINOR A container changed its state on<br />

controller %s. Container : %d.<br />

4 INFORMAT<br />

IONAL<br />

A file system change has occurred on<br />

container %d on controller %s.<br />

6 MAJOR An unknown error occurred on container<br />

%d on adapter %s.<br />

7 MAJOR The container %d on controller %s is no<br />

longer in the mirroring state.<br />

8 CRITICAL A failover operation for controller %s<br />

container %d failed because there was<br />

not enough space available on the<br />

failover device.<br />

9 CRITICAL The container %d on controller %s could<br />

not be unmirrored.<br />

10 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A mirror failover operation started on<br />

controller %s for container %d.<br />

11 CRITICAL A failover operation on controller %s<br />

failed for container %d.<br />

12 MINOR There is no failover device assigned to<br />

container %d on controller %s.<br />

Remarks<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

aacMirrorDriveFailure<br />

Mirror drive failure<br />

aacRaidRebuildStart<br />

Rebuild started<br />

aacRaidRebuildRestart<br />

Rebuild restarted<br />

aacRaidDriveFailure<br />

RAID Drive Failure<br />

aacRaidNoFailover<br />

No failover for RAID<br />

aacRaidNoSpace<br />

Not enough failover space for<br />

RAID<br />

aacSnapshotContainerAlmost<br />

Full<br />

Snapshot almost full<br />

aacSnapshotContainerFull<br />

Snapshot full<br />

aacRaidRebuildComplete<br />

Rebuild complete<br />

aacDeviceFailure<br />

Device failure<br />

aacControllerResume<br />

Controller resume<br />

aacInterfaceUp<br />

Interface up<br />

aacBatteryReconditionRequired<br />

Battery reconditioning<br />

required<br />

aacEnclosureGeneralError<br />

Enclosure general error<br />

aacEnclosureFanError<br />

Enclosure fan error<br />

aacEnclosurePowerSupplyError<br />

Enclosure power supply error<br />

aacEnclosureTempAbnormal<br />

Enclosure temperature<br />

abnormal<br />

aacEnclosureTempOver<br />

Enclosure temperature too<br />

high<br />

aacBatteryDead<br />

Battery dead<br />

aacBatteryImproving<br />

Battery improving<br />

aacBatteryDegrading<br />

Battery degrading<br />

aacBatteryGood<br />

Battery good<br />

13 CRITICAL A drive that was part of the mirror set<br />

(container) %d failed. This occurred on<br />

controller %d.<br />

14 INFORMAT<br />

IONAL<br />

15 INFORMAT<br />

IONAL<br />

B.13 AdaptecArrayController-MIB (aac.mib)<br />

table: AdaptecArrayController-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.10.1.1)<br />

Specific<br />

Level of<br />

importance<br />

A rebuild operation started on controller<br />

%s for container %d.<br />

A rebuild operation restarted on<br />

controller %s for container %d.<br />

16 CRITICAL A drive that was part of the RAID set<br />

(container) %d failed. This occurred on<br />

controller %s.<br />

17 MINOR There is no failover device assigned to<br />

container %d on controller %s.<br />

18 CRITICAL A failover operation for controller %s<br />

container %d failed because there was<br />

not enough space available on the<br />

failover device.<br />

19 MAJOR The snapshot container %d on controller<br />

%s is almost full.<br />

20 CRITICAL The snapshot container %d on controller<br />

%s is full.<br />

21 INFORMAT<br />

IONAL<br />

The rebuild operation on controller %s<br />

for container %d has completed.<br />

22 CRITICAL A device has failed. Controller %s. Bus<br />

%d. ID %d LUN %d.<br />

23 INFORMAT<br />

IONAL<br />

24 INFORMAT<br />

IONAL<br />

The controller %s resumed normal I/O<br />

operations.<br />

The AAC management interface is up.<br />

25 MAJOR The controller %s requires battery<br />

reconditioning.<br />

26 MAJOR An enclosure connected to controller %s<br />

has reported an error.<br />

27 MAJOR An enclosure connected to controller %s<br />

has reported a fan failure.<br />

28 MAJOR An enclosure connected to controller %s<br />

has reported a power supply failure.<br />

29 MAJOR An enclosure connected to controller %s<br />

has reported an abnormal temperature<br />

reading.<br />

30 CRITICAL An enclosure connected to controller %s<br />

has reported a temperature reading above<br />

the user threshold.<br />

31 CRITICAL The battery connected to controller %s is<br />

dead.<br />

32 INFORMAT<br />

IONAL<br />

The battery connected to controller %s is<br />

improving.<br />

33 MAJOR The battery connected to controller %s<br />

has lost charge.<br />

34 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The controller %s reports that its battery<br />

is good.<br />

Remarks<br />

39


40<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

aacControllerPaused<br />

Controller paused<br />

aacContainerCreated<br />

Container created<br />

aacContainerDeleted<br />

Container deleted<br />

aacDeviceFailurePredictionTh<br />

resholdExceeded<br />

Device failure prediction<br />

threshold exceeded<br />

aacDeviceFailurePredictionTe<br />

st<br />

Device failure prediction test<br />

aacDeviceWarning<br />

Device warning<br />

aacDeviceTemperatureWarning<br />

Device temperature warning<br />

aacDeviceDegradedWarning<br />

Device degraded warning<br />

aacDeviceFailurePredictionCo<br />

nfigurationChanged<br />

Device failure prediction<br />

configuration changed<br />

aacGlobalHotSpareReplacedS<br />

uccess<br />

Failover Replaced<br />

aacDedicatedHotSpareReplac<br />

edSuccess<br />

Failover Replaced<br />

aacGlobalHotSpareReplacedT<br />

ooSmall<br />

Failover Replaced<br />

aacDedicatedHotSpareReplac<br />

edTooSmall<br />

Failover Replaced<br />

aacDedicatedHotSpareReplac<br />

edArrayNotExist<br />

Failover Replaced<br />

aacBatteryTemperatureWarning<br />

Battery Temperature Warning<br />

aacBatteryTemperatureCritical<br />

Battery Temperature Critical<br />

aacBatteryTemperatureCritical<br />

Recover<br />

Battery Temperature Critical<br />

Recover<br />

table: AdaptecArrayController-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.10.1.1)<br />

Specific<br />

Level of<br />

importance<br />

35 MINOR The controller %s has been paused.<br />

36 INFORMAT<br />

IONAL<br />

37 INFORMAT<br />

IONAL<br />

Container %d has been created on<br />

controller %s.<br />

Container %d has been deleted on<br />

controller %s.<br />

38 MAJOR A device reported that its Failure<br />

Prediction Threshold had been exceeded.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

39 INFORMAT<br />

IONAL<br />

A Failure Prediction Threshold test<br />

occurred. Controller %s. Bus %d. ID<br />

%d. LUN %d.<br />

40 MAJOR A Device issued a warning. Controller<br />

%s. Bus %d. ID %d LUN %d.<br />

41 MAJOR A Device issued a abnormal temperature<br />

warning. Controller %s. Bus %d. ID %d<br />

LUN %d.<br />

42 MINOR A device reported that its status is<br />

degraded. Controller %s. Bus %d. ID<br />

%d LUN %d.<br />

43 INFORMAT<br />

IONAL<br />

44 INFORMAT<br />

IONAL<br />

45 INFORMAT<br />

IONAL<br />

The failure prediction configuration<br />

changed for a device. Controller %s. Bus<br />

%d. ID %d LUN %d.<br />

A failover device has been replaced on<br />

controller %s.<br />

A failover device has been replaced on<br />

container %d, controller %s.<br />

46 WARNING The failover device that was replaced on<br />

controller %s is too small.<br />

47 WARNING The failover device that was replaced on<br />

container %d, controller %s is too small.<br />

48 WARNING The failover device has been replaced on<br />

container %d, controller %s. However,<br />

container %d does not exist.<br />

49 WARNING The battery connected to controller %s<br />

has reported an over temperature<br />

warning.<br />

50 CRITICAL The battery connected to controller %s,<br />

has reported that it is critically over<br />

temperature.<br />

51 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The battery connected to controller %s,<br />

has reported that it has recovered from a<br />

critical over temperature.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

aacBatteryTemperatureNormal<br />

Battery Temperature Warning<br />

Recover<br />

aacContainerMetadataUnkno<br />

wnError<br />

Container Metadata Unknown<br />

Error<br />

aacContainerMetadataReadErr<br />

or<br />

A metadata read error has<br />

occurred<br />

aacContainerMetadataCRCFai<br />

lureError<br />

Container Metadata CRC<br />

Failure Error<br />

aacContainerMiscompareError<br />

Container Miscompare Error<br />

aacSCSIBusReset<br />

There has been a SCSI bus<br />

reset<br />

aacSenseData<br />

Sense data event<br />

aacMediumError<br />

There has been a device<br />

medium error<br />

aacBadBlockRecoveryStarting<br />

The bad block recovery has<br />

started.<br />

aacBadBlockRecoveryComple<br />

ting<br />

The bad block recovery has<br />

completed<br />

aacInvalidIO<br />

An invalid I/O event has<br />

occurred<br />

aacDisablingChannel<br />

Disabling channel event<br />

aacCannotReadyDevice<br />

System can not ready the<br />

device<br />

aacChannelTimeout<br />

Channel Timeout<br />

aacSenseDataUnknown<br />

Sense data event<br />

aacCommandTimeout<br />

A command timeout has<br />

occurred<br />

52 INFORMAT<br />

IONAL<br />

B.13 AdaptecArrayController-MIB (aac.mib)<br />

table: AdaptecArrayController-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.10.1.1)<br />

Specific<br />

Level of<br />

importance<br />

The battery connected to controller %s,<br />

has returned to normal.<br />

53 CRITICAL Container %d has experienced an<br />

unknown metadata error on controller<br />

%s.<br />

54 CRITICAL A metadata read error has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

55 CRITICAL A metadata CRC faiure has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

56 CRITICAL Container %d has experienced<br />

miscompare error(s) on controller %s.<br />

57 INFORMAT<br />

IONAL<br />

58 INFORMAT<br />

IONAL<br />

There has been a SCSI bus reset.<br />

Controller %s. Bus %d.<br />

A sense data event has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Key %s. ASC %s ASCQ %s.<br />

59 MAJOR There has been a device medium error.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Begin LBA %s End LBA %s.<br />

60 INFORMAT<br />

IONAL<br />

61 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The bad block recovery has started.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

The bad block recovery has completed.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

62 MAJOR An invalid I/O event has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Expected Bytes %d, Actual Bytes %d.<br />

63 MINOR A disabling channel event has occurred.<br />

Controller %s. Bus %d. Error Code %d<br />

64 MAJOR The system can not ready the device.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

65 MAJOR A channel timeout has occurred.<br />

Controller %s. Bus %d.<br />

66 MAJOR A sense data event has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

Key %s. ASC %s ASCQ %s.<br />

67 MAJOR A command timeout has occurred.<br />

Controller %s. Bus %d. ID %d LUN %d.<br />

OpCode %s.<br />

Remarks<br />

41


42<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

aacContainerMediumErrorWa<br />

rning<br />

A medium error was<br />

encountered while rebuilding a<br />

container<br />

68 WARNING A medium error was encountered while<br />

rebuilding a container on Controller %s.<br />

Container %d. Block Number %s.<br />

B.14 DESKTRAP-MIB (desktrap.mib)<br />

The following table shows the DESKTRAP-MIB traps and their outline.<br />

<strong>Trap</strong>s from DeskView <strong>Trap</strong>-Agent.<br />

TRAP-TYPE/<br />

Alarm type<br />

sni<strong>Trap</strong>Error<br />

No Text found in DeskMon.ini<br />

sniSmartOK<br />

SMART hard disk reports OK<br />

sniSmartWarning<br />

SMART hard disk reports<br />

Warning<br />

sniSmartError<br />

SMART hard disk reports<br />

Error.<br />

sniCoverClosed<br />

The cover is closed<br />

sniCoverOpened<br />

The cover has been opened.<br />

sniCoverSensorincorporated<br />

The sensor for securing the<br />

cover is incorporated.<br />

sniCoverSensorMissing<br />

The sensor for securing the<br />

cover is missing or defective<br />

sniCoverRecognition<br />

The cover type cannot be<br />

recognized.<br />

sniCoverRecognitionMissing<br />

The sensor for recognizing the<br />

cover type is missing or<br />

defective.<br />

sniNoShortCurcuit<br />

No short circuit in the mouse,<br />

keyboard or USB interface.<br />

table: AdaptecArrayController-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.10.1.1)<br />

Specific<br />

table: DESKTRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.3)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks<br />

1 MINOR No Text found in DeskMon.ini on %s <strong>Trap</strong> from an<br />

unsupported<br />

application<br />

(DeskView).<br />

Not displayed<br />

normally.<br />

1001 INFORMAT<br />

IONAL<br />

SMART hard disk reports OK on %s ↑<br />

1002 MINOR SMART hard disk reports Warning on %s ↑<br />

1003 CRITICAL SMART hard disk reports Error on %s ↑<br />

2001 INFORMAT<br />

IONAL<br />

The cover is closed on %s ↑<br />

2003 CRITICAL The cover has been opened on %s ↑<br />

3001 INFORMAT<br />

IONAL<br />

The sensor for securing the cover is<br />

incorporated on %s<br />

3003 CRITICAL The sensor for securing the cover is<br />

missing or defective on %s<br />

4001 INFORMAT<br />

IONAL<br />

The cover type cannot be recognized on<br />

%s<br />

4003 CRITICAL The sensor for recognizing the cover type<br />

is missing or defective on %s<br />

5001 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

No short circuit in the mouse, keyboard<br />

or USB interface on %s<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

sniShortCurcuit<br />

Short circuit in the mouse,<br />

keyboard or USB interface.<br />

sniTemperatureOK<br />

The temperature sensor is<br />

functioning<br />

sniTemperatureWarning<br />

The temperature is high<br />

sniTemperatureCritical<br />

The temperature sensor is<br />

defective or the temperature is<br />

too high<br />

sniFanRunning<br />

The fan is running<br />

sniFanNotRunning<br />

The fan is not running<br />

sniFanWornOK<br />

The rotational speed of the fan<br />

is OK.<br />

sniFanWornWarning<br />

The rotational speed of the fan<br />

is almost critical.<br />

sniFanWornCritical<br />

The rotational speed of the fan<br />

is critical.<br />

sniVoltageOk<br />

The voltage monitor is<br />

functioning.<br />

sniVoltageWarning<br />

The voltage is almost critical.<br />

sniVoltageCritical<br />

The voltage monitor is not<br />

functioning or the voltage is<br />

critical.<br />

sniWatchdogOk<br />

The functionality of the<br />

operating system watchdog is<br />

guaranteed.<br />

sniWatchdogCritical<br />

The operating system<br />

watchdog caused too many<br />

consecutive system reboots<br />

and will be deactivated.<br />

sniInternalError<br />

Messages for system<br />

monitoring got lost because<br />

they could not be buffered!.<br />

The buffer has overrun or the<br />

harddisk was full.<br />

sniBIOSErrorLogOK<br />

BIOS error log contains no<br />

current entries<br />

table: DESKTRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.3)<br />

Specific<br />

Level of<br />

importance<br />

5003 CRITICAL Short circuit in the mouse, keyboard or<br />

USB interface on %s<br />

7001 INFORMAT<br />

IONAL<br />

The temperature sensor is functioning on<br />

%s<br />

7002 MINOR The temperature is high on %s ↑<br />

7003 CRITICAL The temperature sensor is defective or<br />

the temperature is too high on %s<br />

8001 INFORMAT<br />

IONAL<br />

The fan is running on %s ↑<br />

8003 CRITICAL The fan is not running on %s ↑<br />

9001 INFORMAT<br />

IONAL<br />

The rotational speed of the fan is OK on<br />

%s<br />

9002 MINOR The rotational speed of the fan is almost<br />

critical on %s<br />

9003 CRITICAL The rotational speed of the fan is critical<br />

on %s<br />

11001 INFORMAT<br />

IONAL<br />

The voltage monitor is functioning on %s ↑<br />

11002 MINOR The voltage is almost critical on %s ↑<br />

11003 CRITICAL The voltage monitor is not functioning or<br />

the voltage is critical on %s<br />

12001 INFORMAT<br />

IONAL<br />

The functionality of the operating system<br />

watchdog is guaranteed on %s<br />

12003 CRITICAL The operating system watchdog caused<br />

too many consecutive system reboots and<br />

will be deactivated on %s<br />

13001 MINOR Messages for system monitoring got lost<br />

because they could not be buffered!. The<br />

buffer has overrun or the harddisk was<br />

full on %s.<br />

14001 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

BIOS error log contains no current<br />

entries on %s<br />

B.14 DESKTRAP-MIB (desktrap.mib)<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks<br />

43


44<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

sniBIOSErrorLogWarning<br />

BIOS reported a non-critical<br />

problem<br />

sniBIOSErrorLogCritical<br />

BIOS reported a critical error<br />

sniAOLPOSTCritical<br />

Power On Self Test (POST)<br />

error.<br />

sniAOLWatchdogCritical<br />

The operating system may be<br />

hung or the computer failed to<br />

boot.<br />

sniAOLCoverOpened<br />

The cover was opened.<br />

sniAOLCPUMissingCritical<br />

The processor was removed<br />

from the computer.<br />

sniAOLHeartbeatCritical<br />

The computer is no longer<br />

available. (Presence Heartbeat<br />

Expired).<br />

sniFreeDiskSpaceOK<br />

Free hard disk space is<br />

sufficient.<br />

sniFreeDiskSpaceWarning<br />

Free hard disk space is low.<br />

sniFreeDiskSpaceError<br />

Free hard disk space is<br />

extremely low.<br />

sniMemoryChangesOK<br />

The memory size has not<br />

changed.<br />

sniMemoryChangesWarning<br />

The memory size increased.<br />

sniMemoryChangesError<br />

The memory size decreased.<br />

sniDeviceChangesOK<br />

No changes in devices.<br />

sniDeviceChangesWarning<br />

A device was added to the<br />

system.<br />

sniDeviceChangesError<br />

A device was removed from<br />

the system.<br />

sniAOLVoltage_Fan_Tempera<br />

tureCritical<br />

A Voltage/Fan/Temperature is<br />

operating out of specification.<br />

sniAOLLANLeashCritical<br />

The computer was recently<br />

reconnected to the network<br />

table: DESKTRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.3)<br />

Specific<br />

Level of<br />

importance<br />

14002 MINOR BIOS reported a non-critical problem on<br />

%s<br />

14003 CRITICAL BIOS reported a critical error on %s ↑<br />

15003 CRITICAL Power On Self Test (POST) error on %s ↑<br />

16003 CRITICAL The operating system may be hung or the<br />

computer failed to boot on %s<br />

17003 CRITICAL The cover was opened on %s ↑<br />

18003 CRITICAL The processor was removed from the<br />

computer %s<br />

20003 CRITICAL The computer %s is no longer available.<br />

(Presence Heartbeat Expired)<br />

21001 INFORMAT<br />

IONAL<br />

Free hard disk space is sufficient on %s. ↑<br />

21002 MINOR Free hard disk space is low on %s. ↑<br />

21003 CRITICAL Free hard disk space is extremely low on<br />

%s.<br />

22001 INFORMAT<br />

IONAL<br />

The memory size has not changed on %s. ↑<br />

22002 MINOR The memory size increased on %s. ↑<br />

22003 CRITICAL The memory size decreased on %s. ↑<br />

23001 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

No changes in devices on %s. ↑<br />

23002 MINOR A device was added to system %s. ↑<br />

23003 CRITICAL A device was removed from system %s. ↑<br />

24003 CRITICAL A Voltage/Fan/Temperature is operating<br />

out of specification on %s<br />

25003 CRITICAL The computer was recently reconnected<br />

to the network on %s<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

sniAOLProcessorTemperature<br />

Critical<br />

The processor temperature is<br />

out of specification.<br />

sniAOLProcessor0MissingCri<br />

tical<br />

The processor P0 was<br />

removed from the computer.<br />

sniAOLProcessor1MissingCri<br />

tical<br />

The processor P1 was<br />

removed from the computer.<br />

sniAOLVoltage_FanCritical<br />

A Voltage/Fan is operating out<br />

of specification.<br />

sniAOLVoltageCritical<br />

A Voltage is operating out of<br />

specification.<br />

sniAOLFanCritical<br />

A Fan is operating out of<br />

specification.<br />

sniAOLFan_TemperatureCriti<br />

cal<br />

A Fan/Temperature is<br />

operating out of specification.<br />

sniAOLVoltage_Temperature<br />

Critical<br />

A Voltage/Temperature is<br />

operating out of specification.<br />

sniAOLNICSMBusSlotCritical<br />

NIC with Capelookout has<br />

been plugged into a PCI slot<br />

without SMBus connection.<br />

sniAOLPresencePongCritical<br />

Received a presence pong<br />

reply.<br />

sniAOLHardwareMonitorCriti<br />

cal<br />

Hardware Monitor has<br />

detected an external event.<br />

sniAOL1_5VGTLVoltageCriti<br />

cal<br />

+1.5 GTL Voltage is out of<br />

specification.<br />

sniAOLCPUCoreVoltageCriti<br />

cal<br />

CPU Core Voltage is out of<br />

specification.<br />

sniAOL3_3VStandbyCritical<br />

+3.3V Standby Voltage is out<br />

of specification.<br />

table: DESKTRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.3)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

26003 CRITICAL The processor temperature is out of<br />

specification on %s<br />

28003 CRITICAL The processor P0 was removed from the<br />

computer on %s<br />

29003 CRITICAL The processor P1 was removed from the<br />

computer on %s<br />

30003 CRITICAL A Voltage/Fan is operating out of<br />

specification on %s<br />

31003 CRITICAL A Voltage is operating out of<br />

specification on %s<br />

32003 CRITICAL A Fan is operating out of specification on<br />

%s<br />

33003 CRITICAL A Fan/Temperature is operating out of<br />

specification on %s<br />

34003 CRITICAL A Voltage/Temperature is operating out<br />

of specification on %s<br />

35003 CRITICAL NIC with Capelookout has been plugged<br />

into a PCI slot without SMBus<br />

connection on %s<br />

36003 CRITICAL Received a presence pong reply on %s ↑<br />

37003 CRITICAL Hardware Monitor has detected an<br />

external event on %s<br />

38003 CRITICAL +1.5 GTL Voltage is out of specification<br />

on %s<br />

39003 CRITICAL CPU Core Voltage is out of specification<br />

on %s<br />

40003 CRITICAL +3.3V Standby Voltage is out of<br />

specification on %s<br />

B.14 DESKTRAP-MIB (desktrap.mib)<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks<br />

45


46<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

sniAOL5VoltageCritical<br />

+5V Voltage is out of<br />

specification.<br />

sniAOLHardwareMonitorInter<br />

nalTemperatureCritical<br />

Hardware Monitor Internal<br />

Temperature is out of<br />

specification.<br />

sniAOLCPUDiodeSensorCriti<br />

cal<br />

CPU Diode Sensor is<br />

operating out of specification.<br />

sniAOLCPUFanCritical<br />

CPU Fan is operating out of<br />

specification.<br />

sniAOLChassisFanCritical<br />

Chassis Fan is operating out of<br />

specification.<br />

sniAOL12VoltageCritical<br />

+12V is operating out of<br />

specification.<br />

sniAOL3_3VoltageCritical<br />

+3.3V is operating out of<br />

specification.<br />

sniAOLCPUDiodeCritical<br />

Open/Short has occurred in the<br />

CPU Diode Sensor.<br />

sniAOL2_5VoltageCritical<br />

+2.5V is operating out of<br />

specification.<br />

sniAOLAmbientTemperature<br />

Critical<br />

Ambient temperature is out of<br />

specification.<br />

sniAOLRemoteTemperatureC<br />

ritical<br />

Remote Temperature is out of<br />

specification.<br />

sniAOLUndockEventCritical<br />

Surprised undock event (no<br />

information is available).<br />

sniFreeSystemDiskSpaceOK<br />

Free hard disk space on system<br />

disk is sufficient.<br />

sniFreeSystemDiskSpaceWarn<br />

ing<br />

Free hard disk space on system<br />

disk is low.<br />

sniFreeSystemDiskSpaceError<br />

Free hard disk space on system<br />

disk is extremely low.<br />

table: DESKTRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.3)<br />

Specific<br />

Level of<br />

importance<br />

41003 CRITICAL +5V Voltage is out of specification on %s ↑<br />

42003 CRITICAL Hardware Monitor Internal Temperature<br />

is out of specification on %s<br />

43003 CRITICAL CPU Diode Sensor is operating out of<br />

specification on %s<br />

44003 CRITICAL CPU Fan is operating out of specification<br />

on %s<br />

45003 CRITICAL Chassis Fan is operating out of<br />

specification on %s<br />

46003 CRITICAL +12V is operating out of specification on<br />

%s<br />

47003 CRITICAL +3.3V is operating out of specification on<br />

%s<br />

48003 CRITICAL Open/Short has occurred in the CPU<br />

Diode Sensor on %s<br />

49003 CRITICAL +2.5V is operating out of specification on<br />

%s<br />

50003 CRITICAL Ambient temperature is out of<br />

specification on %s<br />

51003 CRITICAL Remote Temperature is out of<br />

specification on %s<br />

52003 CRITICAL Surprised undock event (no information<br />

is available) on %s<br />

56001 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Free hard disk space on system disk is<br />

sufficient on %s.<br />

56002 MINOR Free hard disk space on system disk is<br />

low on %s.<br />

56003 CRITICAL Free hard disk space on system disk is<br />

extremely low on %s.<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

sniLeaseExpirationOK<br />

The lease contract has not yet<br />

expired or no expiration date<br />

has been set.<br />

sniLeaseExpirationWarning<br />

The lease contract will expire<br />

soon.<br />

sniLeaseExpirationError<br />

The lease contract has expired.<br />

sniProcessorChangeOK<br />

No processor change<br />

determined.<br />

sniProcessorChangeWarning<br />

A processor has also been<br />

installed or replaced.<br />

sniProcessorChangeError<br />

A processor has been<br />

removed.<br />

57001 INFORMAT<br />

IONAL<br />

B.15 DPT-SCSI-MIB (dptscsi.mib)<br />

The lease contract has not yet expired or<br />

no expiration date has been set on %s.<br />

57002 MINOR The lease contract will expire soon on<br />

%s.<br />

57003 CRITICAL The lease contract has expired on %s. ↑<br />

58001 INFORMAT<br />

IONAL<br />

No processor change determined on %s.<br />

58002 MINOR A processor has also been installed or<br />

replaced on %s.<br />

58003 CRITICAL A processor has been removed on %s.<br />

B.15 DPT-SCSI-MIB (dptscsi.mib)<br />

<strong>Trap</strong>s from Adaptec's I2O-based RAID Card. Refer to the RAID controller manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

dptHbaTemperatureVeryHigh<br />

<strong>Trap</strong><br />

Very high temperature on<br />

controller<br />

dptArrayStatusChangeFailedT<br />

rap<br />

Array failed<br />

dptHbaVoltageChange<strong>Trap</strong><br />

5V Voltage outside range on<br />

controller<br />

dptHbaTemperatureHigh<strong>Trap</strong><br />

High temperature on controller<br />

dptHbaEccRAMErrorUncorre<br />

ctable<strong>Trap</strong><br />

Controller detected an ECC<br />

RAM error that could not be<br />

corrected<br />

dptArrayStatusChangeDegrad<br />

ed<strong>Trap</strong><br />

Array degraded<br />

dptDevReqSenseSeriousError<br />

<strong>Trap</strong><br />

Serious: Request sense data<br />

received.<br />

table: DESKTRAP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.231.2.10.3)<br />

Specific<br />

table: ADAPTECDURALINK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.1597)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

400 CRITICAL Very high temperature on controller %d<br />

401 CRITICAL Array failed on Controller %d Bus %d ID<br />

%d LUN %d.<br />

300 MAJOR 5V Voltage status is now %d on<br />

controller %d<br />

301 MINOR High temperature on controller %d<br />

302 MAJOR Uncorrectable ECC error found on<br />

controller %d<br />

303 MAJOR Array on Controller %d Bus %d ID %d<br />

LUN %d running degraded.<br />

304 MAJOR Serious: Request sense data for controller<br />

%d Bus %d ID %d LUN %d.<br />

↑<br />

↑<br />

Remarks<br />

Remarks<br />

47


48<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

dptDevArrayDataInconsistenc<br />

y<strong>Trap</strong><br />

Array data inconsistency<br />

found.<br />

dptHbaError<strong>Trap</strong><br />

controller error found.<br />

dptDevFailed<strong>Trap</strong><br />

Unprotected drive has failed.<br />

dptDevSmartFailed<strong>Trap</strong><br />

SMART failure reported.<br />

dptHbaAuxVoltageChange<strong>Trap</strong><br />

Auxiliary voltage outside<br />

range on controller<br />

dptHbaVoltageChange2<strong>Trap</strong><br />

5V Voltage outside range on<br />

controller<br />

dptHbaAuxVoltageChange2Tr<br />

ap<br />

Auxiliary voltage outside<br />

range on controller<br />

dptHbaEccRAMErrorCorrecte<br />

d<strong>Trap</strong><br />

ECC RAM Error detected and<br />

corrected.<br />

dptDevBlockReassigned<strong>Trap</strong><br />

Disk block was reassigned<br />

dptDevReqSenseError<strong>Trap</strong><br />

Warning: request sense data<br />

received.<br />

dptHbaVoltageNormal<strong>Trap</strong><br />

Normal 5V voltage on<br />

controller<br />

dptHbaTemperatureNormalTr<br />

ap<br />

Normal temperature on<br />

controller<br />

dptHbaEccRAMErrorNotFou<br />

nd<strong>Trap</strong><br />

ECC RAM Error detected but<br />

not found on correction.<br />

dptDevStatusChanged<strong>Trap</strong><br />

Device status change<br />

dptDevReqSense<strong>Trap</strong><br />

Request sense received from<br />

controller.<br />

dptArrayChange<strong>Trap</strong><br />

Array change.<br />

dptBatteryChange<strong>Trap</strong><br />

Battery status change.<br />

dptHbaAuxVoltageNormal<strong>Trap</strong><br />

Normal auxiliary voltage on<br />

controller<br />

table: ADAPTECDURALINK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.1597)<br />

Specific<br />

Level of<br />

importance<br />

305 MAJOR Array Data Inconsistency: Controller %d<br />

Bus %d ID %d LUN %d.<br />

306 MAJOR controller %d reported a non-SCSI related<br />

error.<br />

307 MAJOR Drive failure on controller %d Bus %d<br />

ID %d LUN %d.<br />

308 MAJOR SMART failure on controller %d Bus %d<br />

ID %d LUN %d reported.<br />

309 MAJOR An auxiliary voltage status is now %d on<br />

controller %d<br />

310 MAJOR 5V Voltage status is now %s on controller<br />

%d<br />

311 MAJOR An auxiliary voltage status is now %s on<br />

controller %d<br />

200 MINOR Correctable ECC RAM Error detected on<br />

controller %d<br />

201 MINOR Block %d reassigned: Controller %d Bus<br />

%d ID %d LUN %d<br />

202 MINOR Warning: Request sense data for<br />

controller %d Bus %d ID %d LUN %d.<br />

100 INFORMAT<br />

IONAL<br />

101 INFORMAT<br />

IONAL<br />

102 INFORMAT<br />

IONAL<br />

103 INFORMAT<br />

IONAL<br />

104 INFORMAT<br />

IONAL<br />

105 INFORMAT<br />

IONAL<br />

106 INFORMAT<br />

IONAL<br />

107 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Normal 5V voltage restored on controller<br />

%d<br />

Normal temperature restored on<br />

controller %d<br />

ECC RAM Error detected at %d on<br />

controller %d, but not found.<br />

Device status on Controller %d Bus %d ID<br />

%d LUN %d : %d.<br />

Request sense data for controller %d Bus<br />

%d ID %d LUN %d.<br />

Array change on controller %d Bus %d<br />

ID %d LUN %d.<br />

Battery status is now %d on controller<br />

%d.<br />

Normal auxiliary voltage restored on<br />

controller %d<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

dptHbaNoSpares<strong>Trap</strong><br />

No hot spares detected on<br />

controller<br />

dptDevStatusChanged2<strong>Trap</strong><br />

Device status change<br />

dptBatteryChange2<strong>Trap</strong><br />

Battery status change.<br />

dptOther<strong>Trap</strong><br />

Controller generated an event<br />

108 INFORMAT<br />

IONAL<br />

109 INFORMAT<br />

IONAL<br />

110 INFORMAT<br />

IONAL<br />

14 INFORMAT<br />

IONAL<br />

No available hot spares were detected<br />

during a scan on controller %d<br />

B.16 MYLEXRAID-MIB (Mlxraid.mib)<br />

Device status on Controller %d Bus %d<br />

ID %d LUN %d : %s.<br />

Battery status is now %s on controller<br />

%d.<br />

Controller generated event: %s<br />

B.16 MYLEXRAID-MIB (Mlxraid.mib)<br />

<strong>Trap</strong>s from the Mylex Disk Array Controller. For message details, refer to the RAID controller (RAID<br />

Manager (GAM: Global Array Manager)) manual.<br />

B.17 MYLEXRAID-FJ-MIB (Mlxraidfj.mib)<br />

<strong>Trap</strong>s from the Mylex Disk Array Controller. For message details, refer to the RAID controller (RAID<br />

Manager (GAM: Global Array Manager)) manual.<br />

B.18 FASTTRAK-MIB (promisev1.mib)<br />

<strong>Trap</strong>s from Promise IDE RAID Adapter. Refer to the RAID controller(RAID<br />

Manager(FastCheckMonitor)) manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

trpUnknown<br />

Unknown - possibly new<br />

driver error code<br />

trpEccError<br />

ECC Error on Disk <br />

LBA <br />

trpDiskDown<br />

Disk Down <br />

trpDiskOffline<br />

Disk Offline <br />

trpDiskPlugin<br />

Disk Plugin <br />

trpAryBadSector<br />

Array had BadSector<br />

at LBA <br />

table: ADAPTECDURALINK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.1597)<br />

Specific<br />

table: FASTTRAK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7933.2.12)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Unknown<br />

2 CRITICAL ECC Error on Disk<br />

3 MAJOR Disk Set Down by Driver<br />

4 MAJOR Disk %d of array %d set offline by driver.<br />

Description: %d<br />

5 MINOR New Disk Plugged In<br />

6 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Bad sector encountered<br />

Remarks<br />

Remarks<br />

49


50<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

trpRebuildStart<br />

Rebuild Started Array <br />

disk <br />

trpSyncStart<br />

Synchronization Started,<br />

Array <br />

trpRetryDisk<br />

Retry Disk Task, disk <br />

lba <br />

trpArrayOffline<br />

Array Offline <br />

trpArrayCritical<br />

Array Critical <br />

trpArrayRebuildComplete<br />

Rebuild Completed, Array<br />

, disk <br />

trpArraySyncComplete<br />

Sync Completed, array<br />

<br />

trpMediaError<br />

Array , disk <br />

has Media Error at LBA<br />

, cmd=,<br />

status=<br />

trpReserveSectorError<br />

Reserved Sector Error, Disk<br />

lba <br />

trpRebuildAborted<br />

Rebuild Aborted, Array<br />

, disk , percent<br />

<br />

trpSyncAborted<br />

Synchronization Aborted,<br />

array , percent<br />

<br />

trpECCFixFail<br />

ECC Fix Failed<br />

trpSyncCompError<br />

Sync Compare Error, Array<br />

, LBA= <br />

trpSwapBoxPowerDown<br />

Swap Box Power Down,<br />

channel , msl <br />

trpSwapBoxPowerUp<br />

Swap Box Power Up, channel<br />

, msl <br />

trpSwapBoxBadSwap<br />

Swap Box, Bad Swap, channel<br />

, msl <br />

trpSwapBoxOverTemp<br />

Swap Box, Over Temp,<br />

channel , msl ,<br />

Temp , C <br />

table: FASTTRAK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7933.2.12)<br />

Specific<br />

Level of<br />

importance<br />

7 INFORMAT<br />

IONAL<br />

8 INFORMAT<br />

IONAL<br />

Rebuild started<br />

Synchronization Started<br />

9 MINOR Retry Disk Task<br />

10 MAJOR Array Offline<br />

11 CRITICAL Array Critical<br />

12 INFORMAT<br />

IONAL<br />

13 INFORMAT<br />

IONAL<br />

Rebuild Completed<br />

Synchronization Completed<br />

14 CRITICAL Media Error on Disk<br />

15 MINOR Reserved Sector Error<br />

16 CRITICAL Rebuild Aborted<br />

17 CRITICAL Sync. Aborted<br />

18 CRITICAL ECC Fix Failed<br />

19 MINOR Sync. Compare Error<br />

20 INFORMAT<br />

IONAL<br />

21 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Swap Box Power Down<br />

Swap Box Power Up<br />

22 MINOR Swap Box, Bad Swap<br />

23 MINOR Swap Box Over Temp<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

trpSwapBoxFanStopped<br />

Swap Box Fan Stop, channel<br />

, msl , RPM=<br />

<br />

trpSwapBox12VOutOfRange<br />

Swap Box, 12V Out of Range,<br />

channel , msl ,<br />

12V=<br />

trpSwapBox5VOutOfRange<br />

Swap Box, 5V Out of Range,<br />

channel , msl ,<br />

5V=<br />

table: FASTTRAK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7933.2.12)<br />

Specific<br />

Level of<br />

importance<br />

24 MINOR Swap Box Fan Stop<br />

25 MINOR 12V Out of Range<br />

26 MINOR 5V Out of Range<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.18 FASTTRAK-MIB (promisev1.mib)<br />

Remarks<br />

51


52<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.19 PROMISE-UNIFIED-MIB (promiseraid.mib)<br />

<strong>Trap</strong>s from Promise FastTrak SATA RAID Adapter. For message details, refer to the RAID controller<br />

(RAID Manager (PAM: Promise Array Management)) manual.<br />

TRAP-TYPE/<br />

Alarm type<br />

trpDiskOffline<br />

Disk offline<br />

trpDiskPlugin<br />

New disk plugged in<br />

trpDiskMediaError<br />

Media error on disk<br />

trpDiskSMARTFail<br />

SMART error on disk<br />

trpDiskAccessRetry<br />

Disk retry<br />

trpDiskECCError<br />

Disk ECC Error<br />

trpDiskTimeOut<br />

Disk timed out<br />

trpDiskBadSector<br />

Bad sector on array<br />

trpArrayMediaError<br />

Array Media Error<br />

trpArrayOffline<br />

Array offline<br />

trpArrayCritical<br />

Array critical<br />

trpArrayCreate<br />

Array creation<br />

trpArrayDelete<br />

Array deletion<br />

trpArrayRebuildStart<br />

Rebuild started<br />

trpArrayAutoRebuildStart<br />

Automatic rebuild started<br />

trpArrayRebuildAborted<br />

Rebuild aborted on array<br />

trpArrayRebuildPaused<br />

Rebuild paused on array<br />

trpArrayRebuildResumed<br />

Rebuild resumed on array<br />

trpArrayRebuildCompleted<br />

Rebuild successfully<br />

completed<br />

trpArrayRebuildFailed<br />

Rebuild failed<br />

trpArraySyncStarted<br />

Synchronization started on<br />

array<br />

table: PROMISE-UNIFIED-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7933.2.12)<br />

Specific<br />

Level of<br />

importance<br />

1 CRITICAL Disk Offline: %s<br />

2 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

New Disk Plugged In: %s<br />

3 MAJOR Disk Media Error: %s<br />

4 MAJOR Disk SMART Fail: %s<br />

5 INFORMAT<br />

IONAL<br />

Retry Disk Access: %s<br />

6 MAJOR ECC Error on Disk: %s<br />

7 MAJOR Disk Time Out: %s<br />

8 CRITICAL Bad sector encountered on array:%s<br />

9 CRITICAL Array has a read/write error: %s<br />

10 CRITICAL Array offline: %s<br />

11 MAJOR Array critical: %s<br />

12 INFORMAT<br />

IONAL<br />

Create array: %s<br />

13 MAJOR Delete array: %s<br />

14 INFORMAT<br />

IONAL<br />

15 INFORMAT<br />

IONAL<br />

Rebuild started on array: %s<br />

Automatic Rebuild started on array: %s<br />

16 MAJOR Rebuild aborted on array: %s<br />

17 MAJOR Rebuild paused on array: %s<br />

18 INFORMAT<br />

IONAL<br />

19 INFORMAT<br />

IONAL<br />

20 INFORMAT<br />

IONAL<br />

21 INFORMAT<br />

IONAL<br />

Rebuild resumed on array: %s<br />

Rebuild completed on array: %s<br />

Rebuild failed on array: %s<br />

Synchronization started on array: %s<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

trpArraySyncAborted<br />

Synchronization aborted on<br />

array<br />

trpArraySyncPaused<br />

Synchronization paused on<br />

array<br />

trpArraySyncResumed<br />

Synchronization resumed on<br />

array<br />

trpArraySyncCompleted<br />

Synchronization successfully<br />

completed on array<br />

trpArraySyncFailed<br />

Synchronization failed on<br />

array<br />

trpSyncComparisonError<br />

Synchronization comparison<br />

error on array<br />

trpSwapBoxOverTemp<br />

Temperature is too high for<br />

enclosure<br />

trpSwapBoxFanStop<br />

Fan stopped for enclosure<br />

trpSwapBox5VOutOfRange<br />

5V over/under threshold for<br />

enclosure<br />

trpSwapBox12VOutOfRange<br />

12V over/under threshold for<br />

enclosure<br />

trpSwapBoxPowerUp<br />

Enclosure power on<br />

trpSwapBoxPowerDown<br />

Enclosure power off<br />

trpUnknown<br />

Unknown - possibly new<br />

driver error code<br />

trpBatteryTempOutOfRange<br />

Battery Temperature Out of<br />

Range<br />

trpBatteryUnstableTemp<br />

Battery Temperature Unstable<br />

trpBatteryVoltOfRange<br />

Battery Voltage Out of Range<br />

trpBatteryUnstableVolt<br />

Battery Voltage Unstable<br />

trpBatteryCommError<br />

Battery Communication Error<br />

trpBatteryBecomeNormal<br />

Battery Communication Error<br />

trpWriteModeChange<br />

Write Mode Change/Toggle<br />

22 INFORMAT<br />

IONAL<br />

23 INFORMAT<br />

IONAL<br />

24 INFORMAT<br />

IONAL<br />

25 INFORMAT<br />

IONAL<br />

B.19 PROMISE-UNIFIED-MIB (promiseraid.mib)<br />

table: PROMISE-UNIFIED-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7933.2.12)<br />

Specific<br />

Level of<br />

importance<br />

Synchronization aborted on array: %s<br />

Synchronization paused on array: %s<br />

Synchronization resumed on array: %s<br />

Synchronization completed on array: %s<br />

26 CRITICAL Synchronization failed on array: %s<br />

27 CRITICAL Synchronization comparison error on<br />

array: %s<br />

28 MAJOR Swap Box Over Temp on enclosure: %s<br />

29 MAJOR Swap Box Fan Stop: %s<br />

30 MAJOR 5V Out of Range for array: %s<br />

31 MAJOR 12V Out of Range for array: %s<br />

32 INFORMAT<br />

IONAL<br />

33 INFORMAT<br />

IONAL<br />

34 INFORMAT<br />

IONAL<br />

Swap Box Power On: %s<br />

Swap Box Power Off: %s<br />

Unknown<br />

35 MAJOR The battery's temperature is out of range<br />

36 MAJOR The battery's temperature is unstable<br />

37 MAJOR The battery's voltage is out of range<br />

38 MAJOR The battery's voltage is unstable<br />

39 MAJOR There is a communication error in the<br />

battery<br />

40 INFORMAT<br />

IONAL<br />

41 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The battery status becomes normal<br />

Write Mode state changed<br />

Remarks<br />

53


54<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

trpDiskErrorFix<br />

Disk error fixed<br />

trpMediaPatrolStart<br />

Media Patrol<br />

trpMediaPatrolStop<br />

Media Patrol<br />

trpMediaPatrolAbort<br />

Media Patrol<br />

trpMediaPatrolComplete<br />

Media Patrol<br />

trpMediaPatrolPause<br />

Media Patrol<br />

trpMediaPatrolResume<br />

Media Patrol<br />

42 INFORMAT<br />

IONAL<br />

43 INFORMAT<br />

IONAL<br />

44 INFORMAT<br />

IONAL<br />

Disk error fixed by entity<br />

Media patrol started<br />

Media patrol stopped<br />

45 CRITICAL Media patrol aborted<br />

46 INFORMAT<br />

IONAL<br />

47 INFORMAT<br />

IONAL<br />

48 INFORMAT<br />

IONAL<br />

Media patrol completed<br />

Media patrol paused<br />

Media patrol resumed<br />

B.20 RAID-Adapter-MIB (megaraid.mib)<br />

<strong>Trap</strong>s from MegaRAID SCSI 320-2. For message details, refer to the RAID controller (RAID Manager<br />

(GAM: Global Array Manager)) manual.<br />

TRAP-TYPE/<br />

Alarm type<br />

rtConfigUpdated<br />

RAID <strong>Trap</strong>: Configuration<br />

Updated<br />

rtPhysicalDriveStateChange<br />

RAID <strong>Trap</strong>: Physical Drive<br />

State Change<br />

rtLogicalDriveStateChange<br />

RAID <strong>Trap</strong>: Logical Drive<br />

State Change<br />

rtInitializeStarted<br />

RAID <strong>Trap</strong>: Initialize Started<br />

rtInitializeCompleted<br />

RAID <strong>Trap</strong>: Initialize<br />

Completed<br />

rtInitializeAborted<br />

RAID <strong>Trap</strong>: Initialize Aborted<br />

rtInitializeFailed<br />

RAID <strong>Trap</strong>: Initialize Failed<br />

rtCheckConsistencyStarted<br />

RAID <strong>Trap</strong>: Check<br />

Consistency Started<br />

rtCheckConsistencyCompleted<br />

RAID <strong>Trap</strong>: Check<br />

Consistency Completed<br />

table: PROMISE-UNIFIED-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.7933.2.12)<br />

Specific<br />

table: RAID-Adapter-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.16.1.1.200)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

9001 INFORMAT<br />

IONAL<br />

9002 INFORMAT<br />

IONAL<br />

9003 INFORMAT<br />

IONAL<br />

9004 INFORMAT<br />

IONAL<br />

9005 INFORMAT<br />

IONAL<br />

9006 INFORMAT<br />

IONAL<br />

9007 INFORMAT<br />

IONAL<br />

9008 INFORMAT<br />

IONAL<br />

9009 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Host Adapter-%d: A New Configuration<br />

has been written.<br />

Adapter-%d, Channel-%d, Target-%d:<br />

Drive State Changed from %s to %s.<br />

Adapter-%d, Logical Drive-%d: State<br />

Changed from %s to %s.<br />

Adapter-%d, Logical Drive-%d:<br />

Initialization Started.<br />

Adapter-%d, Logical Drive-%d:<br />

Initialization Completed Successfully.<br />

Adapter-%d, Logical Drive-%d:<br />

Initialization Aborted by User.<br />

Adapter-%d, Logical Drive-%d:<br />

Initialization Failed.<br />

Adapter-%d, Logical Drive-%d: Check<br />

Consistency Started.<br />

Adapter-%d, Logical Drive-%d: Check<br />

Consistency Completed. No<br />

Inconsistencies Found.<br />

Remarks<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

rtCheckConsistencyAborted<br />

RAID <strong>Trap</strong>: Check<br />

Consistency Aborted<br />

rtConsistencyCorrected<br />

RAID <strong>Trap</strong>: Check<br />

Consistency Corrected<br />

rtCheckConsistencyFailed<br />

RAID <strong>Trap</strong>: Check<br />

Consistency Failed<br />

rtReconstructionStarted<br />

RAID <strong>Trap</strong>: Reconstruction<br />

Started<br />

rtReconstructionCompleted<br />

RAID <strong>Trap</strong>: Reconstruction<br />

Completed<br />

rtReconstructionFailed<br />

RAID <strong>Trap</strong>: Reconstruction<br />

Failed<br />

rtPredictiveFailuresExceeded<br />

RAID <strong>Trap</strong>: Physical Drive<br />

Failure Prediction Threshold<br />

Exceeded<br />

rtPredictiveFailuresFalse<br />

RAID <strong>Trap</strong>: Physical Drive<br />

Predictive Failures [FALSE]<br />

rtCheckConditionStatus<br />

RAID <strong>Trap</strong>: Physical Drive<br />

Check Conditions<br />

rtNewDriveInserted<br />

RAID <strong>Trap</strong>: New Drive<br />

Inserted<br />

rtBatteryMissing<br />

RAID <strong>Trap</strong>: Battery Missing<br />

rtBatteryVolatageLow<br />

RAID <strong>Trap</strong>: Battery Voltage<br />

Low<br />

rtBatteryTemperatureHigh<br />

RAID <strong>Trap</strong>: Battery<br />

Temperature High<br />

table: RAID-Adapter-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.16.1.1.200)<br />

Specific<br />

Level of<br />

importance<br />

9010 INFORMAT<br />

IONAL<br />

9011 INFORMAT<br />

IONAL<br />

9012 INFORMAT<br />

IONAL<br />

9013 INFORMAT<br />

IONAL<br />

9014 INFORMAT<br />

IONAL<br />

9015 INFORMAT<br />

IONAL<br />

9016 INFORMAT<br />

IONAL<br />

9017 INFORMAT<br />

IONAL<br />

9018 INFORMAT<br />

IONAL<br />

9019 INFORMAT<br />

IONAL<br />

9020 INFORMAT<br />

IONAL<br />

9021 INFORMAT<br />

IONAL<br />

9022 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Adapter-%d, Logical Drive-%d: Check<br />

Consistency Aborted by User.<br />

Adapter-%d, Logical Drive-%d: Check<br />

Consistency Operation Completed.<br />

Inconsistencies have been Cured.<br />

Adapter-%d, Logical Drive-%d: Check<br />

Consistency Failed.<br />

Adapter-%d, Logical Drive-%d:<br />

Reconstruction Started.<br />

Adapter-%d, Logical Drive-%d:<br />

Reconstruction Completed Successfully.<br />

Adapter-%d, Logical Drive-%d:<br />

Reconstruction Failed.<br />

Adapter-%d, Channel-%d, Target-%d:<br />

Reported Predictive Failure. (Failure<br />

Threshold Exceeded) Drive Identification<br />

String = %s Sense Key = 0x%x, ASC =<br />

0x%x, ASCQ = 0x%x.<br />

Adapter-%d, Channel-%d, Target-%d:<br />

Reported Predictive Failure. (Failure<br />

Prediction Threshold Exceeded<br />

[FALSE]) Drive Identification String =<br />

%s Sense Key = 0x%x, ASC = 0x%x,<br />

ASCQ = 0x%x.<br />

Adapter-%d, Channel-%d, Target-%d:<br />

Command Completed with Sense_Key-<br />

0x%x ASC-0x%x ASCQ-0x%x.<br />

Adapter-%d, Channel-%d, Target-%d:<br />

New Device Inserted.<br />

Adapter-%d: Battery Module is missing.<br />

Adapter-%d: Battery Module Voltage is<br />

Low.<br />

Adapter-%d: Battery Module<br />

Temperature Exceeded Danger<br />

Threshold.<br />

B.20 RAID-Adapter-MIB (megaraid.mib)<br />

Remarks<br />

55


56<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.21 UPSMAN (Upsman.mib)<br />

<strong>Trap</strong>s from NetpowerView F. Refer to the NetpowerView F manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

communicationLost<br />

UPS: Communication failure<br />

upsOverload<br />

UPS: UPS overload<br />

upsTurnedOff<br />

UPS: Switching off<br />

communicationEstablished<br />

UPS: Communication<br />

established<br />

powerRestored<br />

UPS: power restored<br />

upsOnBattery<br />

UPS: On battery<br />

testStarted<br />

UPS: Test started<br />

testCompleted<br />

UPS: Test completed<br />

upsBatteryLow<br />

UPS: Battery Low<br />

upsShutdownImminent<br />

UPS: Shutdown Imminent<br />

upsmanStarted<br />

UPS: UpsMan service started<br />

upsman<strong>Trap</strong>InputBad<br />

UPS: Abnormal input<br />

condition<br />

upsman<strong>Trap</strong>OutputOverloadR<br />

emoved<br />

UPS: Overload Removed<br />

table: UPSMAN trap (ENTERPRISE : enterprises.1356)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1 CRITICAL Communication with the UPS has been<br />

lost.<br />

2 CRITICAL The UPS has sensed a load greater than<br />

100 percent of its rated capacity.<br />

3 MAJOR The UPS is being switched off by a<br />

management station.<br />

4 INFORMAT<br />

IONAL<br />

5 INFORMAT<br />

IONAL<br />

Communication with the UPS has been<br />

established.<br />

Normal power has been restored to the<br />

UPS.<br />

6 MAJOR The UPS system has switched to battery<br />

backup power.<br />

7 INFORMAT<br />

IONAL<br />

8 INFORMAT<br />

IONAL<br />

Remarks<br />

There is an error in<br />

communication<br />

between the agent and<br />

UPS.<br />

UPS output overload<br />

has occurred.<br />

UPS output is<br />

switched off.<br />

Communication<br />

between the agent<br />

and UPS has been reestablished.<br />

UPS power voltage<br />

has returned to within<br />

the specification<br />

range.<br />

UPS is running on<br />

backup power.<br />

This trap will be sent<br />

in the one minute<br />

period until the UPS<br />

has stopped or<br />

running on backup<br />

power is stopped.<br />

UPS test has been started. This signals the start<br />

of UPS test.<br />

UPS test has been completed. This signals the end<br />

of UPS test.<br />

9 MAJOR UPS Battery Low. The battery capacity<br />

is low.<br />

Refer to<br />

upsBatteryStatus. The<br />

repeat value depends<br />

on<br />

upsConfigIntervalTra<br />

pTime.<br />

10 INFORMAT<br />

IONAL<br />

11 INFORMAT<br />

IONAL<br />

UPS Shutdown Imminent. Signals there is one<br />

minute to server<br />

shutdown.<br />

UpsMan service started. Start service.<br />

12 MAJOR Abnormal input condition UPS power voltage is<br />

beyond the<br />

specification range.<br />

13 INFORMAT<br />

IONAL<br />

Overload Removed UPS output overload<br />

has removed.


TRAP-TYPE/<br />

Alarm type<br />

upsman<strong>Trap</strong>BatteryBad<br />

UPS: Bad battery<br />

upsman<strong>Trap</strong>TempBad<br />

UPS: Bad temperature<br />

upsman<strong>Trap</strong>TempBadRemoved<br />

UPS: Bad temperatureRemove<br />

upsman<strong>Trap</strong>FatalFault<br />

UPS: Fatal fault<br />

B.22 UPS-MIB (RFC1628.mib)<br />

<strong>Trap</strong>s from NetpowerView F. Refer to the NetpowerView F manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

ups<strong>Trap</strong>OnBattery<br />

UPS on Battery<br />

ups<strong>Trap</strong>TestCompleted<br />

UPS Test Completed<br />

ups<strong>Trap</strong>AlarmEntryAdded<br />

UPS Alarm Entry Added<br />

ups<strong>Trap</strong>AlarmEntryRemoved<br />

UPS Alarm Entry Removed<br />

table: UPSMAN trap (ENTERPRISE : enterprises.1356)<br />

Specific<br />

B.22 UPS-MIB (RFC1628.mib)<br />

14 MAJOR Bad battery Battery replacement<br />

necessary.<br />

15 MAJOR Bad temperature Temperature is<br />

beyond the<br />

specification range. It<br />

is not necessary to<br />

identify the place<br />

where the<br />

temperature error<br />

occurred.<br />

For details about the<br />

content of<br />

temperature errors,<br />

refer to<br />

upsAlarmTempBadD<br />

etail.<br />

16 INFORMAT<br />

IONAL<br />

Bad temperatureRemove Temperature has<br />

returned to within the<br />

specification range.<br />

17 CRITICAL Fatal fault UPS fatal fault<br />

occurred.<br />

This appears when a<br />

fatal fault that makes<br />

running on backup<br />

power impossible has<br />

occurred in the UPS.<br />

table: UPS-MIB <strong>Trap</strong> (ENTERPRISE : mib2.33.2)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1 CRITICAL The UPS is on battery power since %d<br />

seconds<br />

2 INFORMAT<br />

IONAL<br />

3 INFORMAT<br />

IONAL<br />

4 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

This trap is sent upon completion of a<br />

UPS diagnostic test.<br />

This trap is sent each time an alarm is<br />

inserted into to the alarm table. It is sent<br />

on the insertion of all alarms except for<br />

upsAlarmOnBattery and<br />

upsAlarmTestInProgress.<br />

This trap is sent each time an alarm is<br />

removed from the alarm table. It is sent<br />

on the removal of all alarms except for<br />

upsAlarmTestInProgress.<br />

Remarks<br />

Remarks<br />

57


58<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.23 PowerNet-MIB (powernet.mib)<br />

<strong>Trap</strong>s from APC UPS Web card. Refer to the APC UPS manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

communicationLost<br />

APC UPS: Communication<br />

failure<br />

upsOverload<br />

APC UPS: UPS overload<br />

upsDiagnosticsFailed<br />

APC UPS: Failed self-test<br />

upsDischarged<br />

APC UPS: batteries are<br />

discharged<br />

upsOnBattery<br />

APC UPS: On battery<br />

smartBoostOn<br />

APC UPS: SmartBoost<br />

lowBattery<br />

APC UPS: Low battery<br />

communicationEstablished<br />

APC UPS: Communication<br />

established<br />

powerRestored<br />

APC UPS: Utility restored<br />

upsDiagnosticsPassed<br />

APC UPS: Passed self-test<br />

returnFromLowBattery<br />

APC UPS: Battery normal<br />

upsTurnedOff<br />

APC UPS: Switching off<br />

upsSleeping<br />

APC UPS: Going to sleep<br />

upsWokeUp<br />

APC UPS: Wake up<br />

upsRebootStarted<br />

APC UPS: Starting reboot<br />

upsDipSwitchChanged<br />

APC UPS: DIP switch altered<br />

upsBatteryNeedsReplacement<br />

APC UPS: UPS batteries<br />

needs replacement<br />

contactFault<br />

APC M-UPS: Contact fault<br />

contactFaultResolved<br />

APC M-UPS: Contact normal<br />

hardwareFailureBypass<br />

APC UPS: On bypass due to<br />

internal fault<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1 CRITICAL Communication lost between the agent<br />

and the UPS.<br />

2 CRITICAL The UPS has sensed a load greater than<br />

100 percent of its rated capacity.<br />

3 CRITICAL The UPS has failed its internal self-test.<br />

4 CRITICAL The UPS batteries are discharged.<br />

5 MAJOR The UPS is now providing battery<br />

backup power.<br />

6 MINOR The UPS has enabled SmartBoost.<br />

7 CRITICAL The UPS system's batteries are low and<br />

will soon be exhausted.<br />

8 INFORMAT<br />

IONAL<br />

9 INFORMAT<br />

IONAL<br />

10 INFORMAT<br />

IONAL<br />

11 INFORMAT<br />

IONAL<br />

Communication established between the<br />

agent and the UPS.<br />

Normal power has been restored to the<br />

UPS.<br />

The UPS has passed its internal self-test.<br />

The UPS has returned from a low battery<br />

condition.<br />

12 MAJOR The UPS is being switched off by a<br />

management station.<br />

13 MAJOR The UPS is going into sleep mode.<br />

14 INFORMAT<br />

IONAL<br />

The UPS has returned from sleep mode.<br />

15 MAJOR The UPS has started its reboot sequence.<br />

16 MINOR The DIP switch settings on the UPS have<br />

been changed.<br />

17 CRITICAL The UPS batteries require immediate<br />

replacement.<br />

18 CRITICAL A Measure-UPS contact closure has<br />

faulted.<br />

19 INFORMAT<br />

IONAL<br />

A Measure-UPS contact closure has<br />

returned to it's default state.<br />

20 CRITICAL The UPS is on bypass due to an internal<br />

fault.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

softwareBypass<br />

APC UPS: On bypass by user<br />

via software or panel<br />

switchedBypass<br />

APC UPS: On bypass initiated<br />

by user<br />

returnFromBypass<br />

APC UPS: UPS has returned<br />

from bypass<br />

bypassPowerSupplyFailure<br />

APC UPS: Base module<br />

bypass power supply needs<br />

repair<br />

baseFanFailure<br />

APC UPS: Base module fan<br />

needs repair<br />

batteryPackCommLost<br />

APC UPS: Communication<br />

lost with battery packs<br />

batteryPackCommEstablished<br />

APC UPS: Communication<br />

established with battery packs<br />

calibrationStart<br />

APC UPS: Calibration<br />

initiated<br />

restartAgent<br />

APC SNMP Agent: Agent<br />

restarting<br />

upsTurnedOn<br />

APC UPS: A UPS is turned<br />

on.<br />

smartAvrReducing<br />

APC UPS: Smart-AVR<br />

reducing<br />

codeAuthenticationDone<br />

APC CODE: Authentication<br />

on agent code image is done.<br />

upsOverloadCleared<br />

APC UPS: Overload cleared.<br />

smartBoostOff<br />

APC UPS: Smartboost off.<br />

smartAvrReducingOff<br />

APC UPS: Smart-AVR<br />

reducing off<br />

upsBatteryReplaced<br />

APC UPS: Bad battery<br />

replaced<br />

calibrationEnd<br />

APC UPS: Calibration end<br />

dischargeCleared<br />

APC UPS: Discharge cleared.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

21 MINOR UPS put on bypass by user via software<br />

or front UPS panel.<br />

22 MINOR UPS put on bypass by user.<br />

23 INFORMAT<br />

IONAL<br />

The UPS has returned from bypass mode.<br />

24 CRITICAL The base module bypass power supply<br />

needs repair.<br />

25 CRITICAL The base module fan needs repair.<br />

26 MINOR Communication lost with external battery<br />

packs, check battery signal cable.<br />

27 INFORMAT<br />

IONAL<br />

28 INFORMAT<br />

IONAL<br />

29 INFORMAT<br />

IONAL<br />

30 INFORMAT<br />

IONAL<br />

Communication established with external<br />

battery packs.<br />

A battery run time calibration test has<br />

been initiated.<br />

Agent restarting as commanded by<br />

manager.<br />

A UPS is turned on.<br />

31 MINOR The UPS has enabled Smart-AVR voltage<br />

reduction.<br />

32 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Authentication on agent code image is<br />

done.<br />

33 MINOR The overload condition has been cleared.<br />

34 MINOR The UPS has returned from smartboost.<br />

35 MINOR The UPS has returned from Smart-AVR<br />

voltage reduction.<br />

36 MINOR The UPS has returned from a bad battery<br />

fault.<br />

37 MINOR The UPS has finished calibrating<br />

38 MINOR The UPS discharge condition has been<br />

cleared.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

59


60<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

gracefullShutdown<br />

APC UPS: A gracefull<br />

shutdown has been initiated.<br />

outletOn<br />

APC PDU: State change.<br />

outletOff<br />

APC PDU: State change.<br />

outletReboot<br />

APC PDU: State change.<br />

configChangeSNMP<br />

APC: State change.<br />

configChangeOutlet<br />

APC PDU: State change.<br />

accessViolationConsole<br />

APC: Access violation.<br />

accessViolationHTTP<br />

APC: Access violation.<br />

passwordChange<br />

APC: Password change.<br />

badVoltage<br />

APC UPS: Bad output voltage.<br />

badVoltageCleared<br />

APC UPS: The bad voltage<br />

output condition has been<br />

cleared.<br />

chargerFailure<br />

APC UPS: The battery charger<br />

has failed.<br />

chargerFailureCleared<br />

APC UPS: The battery charger<br />

failure condition has been<br />

cleared.<br />

batteryOverTemperature<br />

APC UPS: The battery<br />

temperature threshold has<br />

been violated.<br />

batteryOverTemperatureClear<br />

ed<br />

APC UPS: The battery over<br />

temperature has been cleared.<br />

smartRelayFault<br />

APC UPS: SmartBoost(TM)<br />

or SmartTrim(TM) relay fault.<br />

smartRelayFaultCleared<br />

APC UPS: SmartBoost(TM)<br />

or SmartTrim(TM) relay fault<br />

has been cleared.<br />

humidityThresholdViolation1<br />

APC UPS: Probe 1 humidity<br />

threshold violated.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

39 MINOR A gracefull shutdown has been initiated.<br />

41 WARNING An OUTLET has been turned on<br />

42 WARNING An OUTLET has turned off.<br />

43 WARNING An OUTLET has rebooted.<br />

44 WARNING The SNMP configuration has been<br />

changed.<br />

45 WARNING An outlet configuration has been<br />

changed.<br />

46 WARNING Three unsuccessful logins have been<br />

attempted.<br />

47 WARNING An unsuccessful attempt to login via<br />

HTTP.<br />

48 WARNING Someone has changed the password on<br />

the PDU.<br />

49 WARNING The output voltage is not within<br />

acceptable range.<br />

50 INFORMAT<br />

IONAL<br />

The output voltage has returned to an<br />

acceptable level.<br />

51 WARNING The battery charger has failed.<br />

52 INFORMAT<br />

IONAL<br />

The battery charger failure condition has<br />

been cleared.<br />

53 WARNING The battery temperature threshold has<br />

been violated.<br />

54 INFORMAT<br />

IONAL<br />

The battery over temperature has been<br />

cleared.<br />

55 WARNING SmartBoost(TM) or SmartTrim(TM)<br />

relay fault.<br />

56 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

SmartBoost(TM) or SmartTrim(TM)<br />

relay fault has been cleared.<br />

57 WARNING Probe 1 humidity threshold violated.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

humidityThresholdViolationCl<br />

eared1<br />

APC MEASURE-UPS: A<br />

humidity threshold violation<br />

has been cleared on probe 1.<br />

temperatureThresholdViolatio<br />

n1<br />

APC MEASURE-UPS: A<br />

temperature threshold has<br />

been violated on probe 1.<br />

temperatureThresholdViolatio<br />

nCleared1<br />

APC MEASURE-UPS: A<br />

temperature threshold<br />

violation has been cleared on<br />

probe 1.<br />

humidityThresholdViolation2<br />

APC MEASURE-UPS: A<br />

humidity threshold has been<br />

violated on probe 2.<br />

humidityThresholdViolationCl<br />

eared2<br />

APC MEASURE-UPS: A<br />

humiditythreshold violation<br />

has been cleared on probe 2.<br />

temperatureThresholdViolatio<br />

n2<br />

APC MEASURE-UPS: A<br />

temperature threshold has<br />

been violated on probe 2.<br />

temperatureThresholdViolatio<br />

nCleared2<br />

APC MEASURE-UPS: A<br />

temperature threshold<br />

violation has been cleared on<br />

probe 2.<br />

mupsCommunicationEstablish<br />

ed<br />

APC MUPS: Communication<br />

established with the Measure-<br />

UPS<br />

mupsCommunicationLost<br />

APC MUPS: MUPS<br />

Communication failure<br />

batteryIncrease<br />

APC UPS: The number of<br />

batteries has increased.<br />

batteryDecrease<br />

APC UPS: The number of<br />

batteries has decreased.<br />

powerModuleIncrease<br />

APC UPS: The number of<br />

power modules has increased.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

58 INFORMAT<br />

IONAL<br />

A humidity threshold violation has been<br />

cleared on probe 1.<br />

59 CRITICAL A temperature threshold has been<br />

violated on probe 1.<br />

60 MINOR A temperature threshold violation has<br />

been cleared on probe 1.<br />

61 CRITICAL A humidity threshold has been violated<br />

on probe 2.<br />

62 INFORMAT<br />

IONAL<br />

A humidity threshold violation has been<br />

cleared on probe 2.<br />

63 CRITICAL A temperature threshold has been<br />

violated on probe 2.<br />

64 INFORMAT<br />

IONAL<br />

65 INFORMAT<br />

IONAL<br />

A tempreature threshold violation has<br />

been cleared on probe 2.<br />

Communication established between the<br />

agent and the MUPS.<br />

66 CRITICAL Communication lost between the agent<br />

and the MUPS.<br />

67 INFORMAT<br />

IONAL<br />

68 INFORMAT<br />

IONAL<br />

69 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The number of batteries has increased.<br />

The number of batteries has decreased.<br />

The number of power modules has<br />

increased.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

61


62<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

powerModuleDecrease<br />

APC UPS: The number of<br />

power modules has decreased.<br />

intelligenceModuleInserted<br />

APC UPS: An intelligence<br />

module has been inserted.<br />

intelligenceModuleRemoved<br />

APC UPS: An intelligence<br />

module has been removed.<br />

rintelligenceModuleInserted<br />

APC UPS: A redundant<br />

intelligence module has been<br />

inserted.<br />

rintelligenceModuleRemoved<br />

APC UPS: An redundant<br />

intelligence module has been<br />

removed.<br />

extBatteryFrameIncease<br />

APC UPS: An external battery<br />

frame has been added.<br />

extBatteryFrameDecrease<br />

APC UPS: An external battery<br />

frame has been removed.<br />

abnormalCondition<br />

APC UPS: An abnormal<br />

condition has been detected.<br />

abnormalConditionCleared<br />

APC UPS: An abnormal<br />

condition has been cleared.<br />

deviceStatusChange<br />

APC : The status of the device<br />

being monitored has changed.<br />

noBatteries<br />

APC UPS: No batteries<br />

attached.<br />

noBatteriesCleared<br />

APC UPS: The no batteries<br />

attached condition has been<br />

cleared.<br />

userAdded<br />

APC: A new user has been<br />

added.<br />

userDeleted<br />

APC: A user has been deleted.<br />

userModified<br />

APC: A user has been<br />

modified.<br />

msvmCommunicationEstablis<br />

hed<br />

APC: Communications with<br />

the MasterSwitch VM has<br />

been established.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

70 INFORMAT<br />

IONAL<br />

71 INFORMAT<br />

IONAL<br />

72 INFORMAT<br />

IONAL<br />

73 INFORMAT<br />

IONAL<br />

74 INFORMAT<br />

IONAL<br />

75 INFORMAT<br />

IONAL<br />

76 INFORMAT<br />

IONAL<br />

The number of power modules has<br />

decreased.<br />

An intelligence module has been<br />

inserted.<br />

An intelligence module has been<br />

removed.<br />

A redundant intelligence module has<br />

been inserted.<br />

An redundant intelligence module has<br />

been removed.<br />

An external battery frame has been<br />

added.<br />

An external battery frame has been<br />

removed.<br />

77 MAJOR An abnormal condition has been<br />

detected.<br />

78 INFORMAT<br />

IONAL<br />

79 INFORMAT<br />

IONAL<br />

An abnormal condition has been cleared.<br />

The status of the device being monitored<br />

has changed.<br />

80 WARNING The UPS has no batteries attached.<br />

81 INFORMAT<br />

IONAL<br />

82 INFORMAT<br />

IONAL<br />

83 INFORMAT<br />

IONAL<br />

84 INFORMAT<br />

IONAL<br />

85 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The UPS's batteries have been attached.<br />

A new user has been added.<br />

A user has been deleted.<br />

A user has been modified.<br />

Communications with the MasterSwitch<br />

VM has been established.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

msvmCommunicationLost<br />

APC: Communications with<br />

the MasterSwitch VM has<br />

been lost.<br />

msvmOverload<br />

APC: The MasterSwitch VM<br />

is near or at an overload<br />

condition.<br />

msvmOverloadCleared<br />

APC: The overload condition<br />

on the MasterSwitch VM has<br />

been cleared.<br />

msvmOutletOn<br />

APC: An outlet on the<br />

MasterSwitch VM has turned<br />

on.<br />

msvmOutletOff<br />

APC: An outlet on the<br />

MasterSwitch VM has turned<br />

off.<br />

msvmDeviceConfigChange<br />

APC: A device configuration<br />

change has been made on a<br />

MasterSwitch VM.<br />

msvmOutletConfigChange<br />

APC: An outlet configuration<br />

change has been made on a<br />

MasterSwitch VM.<br />

msvmLowLoad<br />

APC: The MasterSwitch VM<br />

has violated the low load<br />

threshold.<br />

msvmLowLoadCleared<br />

APC: The low load condition<br />

on the MasterSwitch VM has<br />

been cleared.<br />

msvmNearOverload<br />

APC: The MasterSwitch VM<br />

is near or at an overload<br />

condition.<br />

msvmNearOverloadCleared<br />

APC: The overload condition<br />

on the MasterSwitch VM has<br />

been cleared.<br />

msvmPowerSupplyStatusCha<br />

nge<br />

APC: The power supply status<br />

of the MasterSwitch VM has<br />

changed.<br />

mspCommunicationEstablished<br />

APC: Communications with<br />

the MasterSwitch plus has<br />

been established.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

86 INFORMAT<br />

IONAL<br />

87 INFORMAT<br />

IONAL<br />

88 INFORMAT<br />

IONAL<br />

89 INFORMAT<br />

IONAL<br />

90 INFORMAT<br />

IONAL<br />

91 INFORMAT<br />

IONAL<br />

92 INFORMAT<br />

IONAL<br />

93 INFORMAT<br />

IONAL<br />

94 INFORMAT<br />

IONAL<br />

95 INFORMAT<br />

IONAL<br />

96 INFORMAT<br />

IONAL<br />

97 INFORMAT<br />

IONAL<br />

98 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Communications with the MasterSwitch<br />

VM has been lost.<br />

The MasterSwitchVM is near or at an<br />

overload condition.<br />

The overload condition on the<br />

MasterSwitch VM has been cleared.<br />

An outlet on the MasterSwitch VM has<br />

turned on.<br />

An outlet on the MasterSwitch VM has<br />

turned off.<br />

A device configuration change has been<br />

made on a MasterSwitch VM.<br />

An outlet configuration change has been<br />

made on a MasterSwitch VM.<br />

The MasterSwitch VM has violated the<br />

low load threshold.<br />

The low load condition on the<br />

MasterSwitch VM has been cleared.<br />

The MasterSwitchVM is near or at an<br />

overload condition.<br />

The overload condition on the<br />

MasterSwitch VM has been cleared.<br />

The power supply status of the<br />

MasterSwitch VM has changed.<br />

Communications with the MasterSwitch<br />

plus has been established.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

63


64<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

mspCommunicationLost<br />

APC: Communications with<br />

the MasterSwitch plus has<br />

been lost.<br />

mspOutletOn<br />

APC: An outlet on the<br />

MasterSwitch plus has turned<br />

on.<br />

mspOutletOff<br />

APC: An outlet on the<br />

MasterSwitch plus has turned<br />

off.<br />

mspDeviceConfigChange<br />

APC: A device configuration<br />

change has been made on a<br />

MasterSwitch plus.<br />

mspOutletConfigChange<br />

APC: An outlet configuration<br />

change has been made on a<br />

MasterSwitch plus.<br />

rsSourceSwitched<br />

APC Redundant Switch: The<br />

Redundant Switch has<br />

switched source.<br />

rsLostRedundancy<br />

APC Redundant Switch: The<br />

Redundant Switch has lost<br />

redundancy.<br />

rsRedundancyRestored<br />

APC Redundant Switch:<br />

Redundancy has been restored<br />

to the Redundant Switch .<br />

rsConfigChange<br />

APC: A configuration change<br />

has been made on a Redundant<br />

Switch.<br />

rsCommunicationEstablished<br />

APC: Communications with<br />

the Redundant Switch has<br />

been established.<br />

rsCommunicationLost<br />

APC: Communications with<br />

the Redundant Switch has<br />

been lost.<br />

dcCommunicationEstablished<br />

APC: Communications with<br />

the DC power plant has been<br />

established.<br />

dcCommunicationLost<br />

APC: Communications with<br />

the DC power plant has been<br />

lost.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

99 INFORMAT<br />

IONAL<br />

100 INFORMAT<br />

IONAL<br />

101 INFORMAT<br />

IONAL<br />

102 INFORMAT<br />

IONAL<br />

103 INFORMAT<br />

IONAL<br />

104 INFORMAT<br />

IONAL<br />

Communications with the MasterSwitch<br />

plus has been lost.<br />

An outlet on the MasterSwitch plus has<br />

turned on.<br />

An outlet on the MasterSwitch plus has<br />

turned off.<br />

A device configuration change has been<br />

made on a MasterSwitch plus.<br />

An outlet configuration change has been<br />

made on a MasterSwitch plus.<br />

The Redundant Switch has switched<br />

source.<br />

105 MAJOR The Redundant Switch has has lost<br />

redundancy.<br />

106 INFORMAT<br />

IONAL<br />

107 INFORMAT<br />

IONAL<br />

108 INFORMAT<br />

IONAL<br />

Redundancy has been restored to the<br />

Redundant Switch.<br />

A configuration change has been made<br />

on a Redundant Switch.<br />

Communications with the Redundant<br />

Switch has been established.<br />

109 CRITICAL Communications with the Redundant<br />

Switch has been lost.<br />

110 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Communications with the DC power<br />

plant has been established.<br />

111 CRITICAL Communications with the DC power<br />

plant has been lost.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

dcActivePINChanged<br />

APC: The active PIN on the<br />

DC controller has been<br />

changed.<br />

dcMajorAlarm<br />

APC: A Major alarm is active<br />

in the DC power plant.<br />

dcMajorAlarmCleared<br />

APC: A Major alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcMinorAlarm<br />

APC: A Minor alarm is active<br />

in the DC power plant.<br />

dcMinorAlarmCleared<br />

APC: A Minor alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcOutputRelayOn<br />

APC: An output relay has<br />

gone on.<br />

dcOutputRelayOff<br />

APC: An output relay has<br />

gone off.<br />

dcInputRelayOn<br />

APC: An input relay has gone<br />

on.<br />

dcInputRelayOff<br />

APC: An input relay has gone<br />

off.<br />

logicPowerSuppliesIncreased<br />

APC UPS: The number of<br />

system power supplies has<br />

increased.<br />

logicPowerSuppliesDecreased<br />

APC UPS: The number of<br />

system power supplies has<br />

decreased.<br />

externalSwitchGearClosed<br />

APC UPS: External Switch<br />

Gear closed.<br />

externalSwitchGearOpened<br />

APC UPS: External Switch<br />

Gear opened.<br />

generalDeviceEvent<br />

APC Device event<br />

atsSourceSwitched<br />

APC Automatic Transfer<br />

Switch: The ATS has switched<br />

source<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

112 INFORMAT<br />

IONAL<br />

The active PIN on the DC controller has<br />

been changed.<br />

113 CRITICAL A Major alarm is active in the DC power<br />

plant.<br />

114 INFORMAT<br />

IONAL<br />

115 INFORMAT<br />

IONAL<br />

116 INFORMAT<br />

IONAL<br />

117 INFORMAT<br />

IONAL<br />

118 INFORMAT<br />

IONAL<br />

119 INFORMAT<br />

IONAL<br />

120 INFORMAT<br />

IONAL<br />

121 INFORMAT<br />

IONAL<br />

122 INFORMAT<br />

IONAL<br />

123 INFORMAT<br />

IONAL<br />

124 INFORMAT<br />

IONAL<br />

125 INFORMAT<br />

IONAL<br />

126 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A Major alarm is no longer active in the<br />

DC power plant.<br />

A Minor alarm is active in the DC power<br />

plant.<br />

A Minor alarm is no longer active in the<br />

DC power plant.<br />

An output relay has gone on in the DC<br />

power plant.<br />

An output relay has gone off in the DC<br />

power plant.<br />

An input relay has gone on in the DC<br />

power plant.<br />

An input relay has gone off in the DC<br />

power plant.<br />

The number of system power supplies<br />

has increased.<br />

The number of system power supplies<br />

has decreased.<br />

External Switch Gear closed.<br />

External Switch Gear opened.<br />

APC Device event.<br />

The Automatic Transfer Switch has<br />

switched source.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

65


66<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

atsLostRedundancy<br />

APC Automatic Transfer<br />

Switch: The ATS has lost<br />

redundancy.<br />

atsRedundancyRestored<br />

APC Automatic Transfer<br />

Switch: Redundancy has been<br />

restored.<br />

atsConfigChange<br />

APC Automatic Transfer<br />

Switch: ATS configuration<br />

changed.<br />

atsCommunicationEstablished<br />

APC Automatic Transfer<br />

Switch: Communications<br />

established.<br />

atsCommunicationLost<br />

APC Automatic Transfer<br />

Switch: Communications lost.<br />

atsOverCurrent<br />

APC Automatic Transfer<br />

Switch: Output Current<br />

exceeded threshold.<br />

atsOverCurrentCleared<br />

APC Automatic Transfer<br />

Switch: Output Current below<br />

threshold.<br />

atsPowerSupplyFailure<br />

APC Automatic Transfer<br />

Switch: The ATS Power<br />

Supply has failed.<br />

atsPowerSupplyFailureCleared<br />

APC Automatic Transfer<br />

Switch: Power Supply Failure<br />

Cleared.<br />

dcMainsFailAlarm<br />

APC: A Mains Fail alarm is<br />

active in the DC power plant.<br />

dcMainsFailAlarmCleared<br />

APC: Mains Fail alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcFanFailAlarm<br />

APC: A Fan Fail alarm is<br />

active in the DC power plant.<br />

dcFanFailAlarmCleared<br />

APC: A Fan Fail alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcRectifierOvertempAlarm<br />

APC: Rect. Overtemp alarm is<br />

active in the power plant.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

127 MAJOR The Automatic Transfer Switch has has<br />

lost redundancy.<br />

128 INFORMAT<br />

IONAL<br />

129 INFORMAT<br />

IONAL<br />

130 INFORMAT<br />

IONAL<br />

Redundancy has been restored to the<br />

Automatic Transfer Switch.<br />

A configuration change has been made<br />

on a Automatic Transfer Switch.<br />

Communications with the Automatic<br />

Transfer Switch has been established.<br />

131 MAJOR Communications with the Automatic<br />

Transfer Switch has been lost.<br />

132 MAJOR Output Current has exceeded Threshold.<br />

133 INFORMAT<br />

IONAL<br />

Output Current has returned below<br />

threshold.<br />

134 MAJOR The Automatic Transfer Switch Power<br />

Supply has failed.<br />

135 INFORMAT<br />

IONAL<br />

The Automatic Transfer Switch Power<br />

Supply Failure Cleared.<br />

136 WARNING A Mains Fail alarm is active in the DC<br />

power plant.<br />

137 INFORMAT<br />

IONAL<br />

Mains Fail alarm is no longer active in<br />

the DC power plant.<br />

138 WARNING A Fan Fail alarm is active in the DC<br />

power plant.<br />

139 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A Fan Fail alarm is no longer active in<br />

the DC power plant.<br />

140 WARNING Rect. Overtemp alarm is active in the<br />

power plant.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

dcRectifierOvertempAlarmCl<br />

eared<br />

APC: Rect. Overtmp alarm is<br />

no longer active in the power<br />

plant.<br />

dcCurrentLimitAlarm<br />

APC: A Current Limit alarm is<br />

active in the power plant.<br />

dcCurrentLimitAlarmCleared<br />

APC: Current Limit alarm is<br />

no longer active in the power<br />

plant.<br />

dcRectifierFailAlarm<br />

APC: A Rect. Fail alarm is<br />

active in the power plant.<br />

dcRectifierFailAlarmCleared<br />

APC: Rect. Fail alarm is no<br />

longer active in the power<br />

plant.<br />

dcMultRectFailAlarm<br />

APC: Multiple Rect. Fail<br />

alarm is active in the power<br />

plant.<br />

dcMultRectFailAlarmCleared<br />

APC: Mult Rect Fail alarm is<br />

no longer active in the<br />

powerplant.<br />

dcBatteryBreakerAlarm<br />

APC: Batt. Breaker alarm is<br />

active in the power plant.<br />

dcBatteryBreakerAlarmCleared<br />

APC: Batt. Breaker alarm is<br />

no longer active in the power<br />

plant.<br />

dcRectifierOVPAlarm<br />

APC: A Rect. OVP alarm is<br />

active in the power plant.<br />

dcRectifierOVPAlarmCleared<br />

APC: A Rect. OVP alarm is no<br />

longer active in the power<br />

plant.<br />

dcLVDImminentAlarm<br />

APC: A LVD Imminent alarm<br />

is active in the power plant.<br />

dcLVDImminentAlarmCleared<br />

APC: A LVD Imminent alarm<br />

is no longer active in the<br />

power plant.<br />

dcFuseCBAlarm<br />

APC: A Fuse/CB alarm alarm<br />

is active in the DC power<br />

plant.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

141 INFORMAT<br />

IONAL<br />

Rect. Overtmp alarm is no longer active<br />

in the power plant.<br />

142 WARNING A Current Limit alarm is active in the<br />

power plant.<br />

143 INFORMAT<br />

IONAL<br />

Current Limit alarm is no longer active in<br />

the power plant.<br />

144 WARNING A Rect. Fail alarm is active in the power<br />

plant.<br />

145 INFORMAT<br />

IONAL<br />

Rect. Fail alarm is no longer active in the<br />

power plant.<br />

146 WARNING Multiple Rect. Fail alarm is active in the<br />

powerplant.<br />

147 INFORMAT<br />

IONAL<br />

Mult Rect Fail alarm is no longer active<br />

in the powerplant.<br />

148 WARNING Batt. Breaker alarm is active in the power<br />

plant.<br />

149 INFORMAT<br />

IONAL<br />

Batt. Breaker alarm is no longer active in<br />

the power plant.<br />

150 WARNING A Rect. OVP alarm is active in the power<br />

plant.<br />

151 INFORMAT<br />

IONAL<br />

A Rect. OVP alarm is no longer active in<br />

the power plant.<br />

152 WARNING A LVD Imminent alarm is active in the<br />

powerplant.<br />

153 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A LVD Imminent alarm is no longer<br />

active in the powerplant.<br />

154 WARNING A Fuse/CB alarm is active in the DC<br />

power plant.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

67


68<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

dcFuseCBAlarmCleared<br />

APC: A Fuse/CB alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcBatteryTestFail<br />

APC: A Battery Test failed in<br />

the DC power plant.<br />

dcTemperatureAlarm<br />

APC: A Temperature alarm is<br />

active in the power plant.<br />

dcTemperatureAlarmCleared<br />

APC: A Temperature alarm is<br />

no longer active in the power<br />

plant.<br />

dcHumidityAlarm<br />

APC: A Humidity alarm is<br />

active in the DC power plant.<br />

dcHumidityAlarmCleared<br />

APC: A Humidity alarm is no<br />

longer active in the DC power<br />

plant.<br />

dcBBCommunicationEstablis<br />

hed<br />

APC: Power plant bridging<br />

board communications<br />

established.<br />

dcBBCommunicationLost<br />

APC: Power plant bridging<br />

board communications lost.<br />

iemHighTempThresholdViolat<br />

ion<br />

APC IEM: High temperature<br />

threshold violation.<br />

iemHighTempThresholdViolat<br />

ionCleared<br />

APC IEM: High temperature<br />

threshold violation cleared.<br />

iemLowTempThresholdViolat<br />

ion<br />

APC IEM: Low temperature<br />

threshold violation.<br />

iemLowTempThresholdViolat<br />

ionCleared<br />

APC IEM: Low temperature<br />

threshold violation cleared.<br />

iemHighHumidThresholdViol<br />

ation<br />

APC IEM: High humidity<br />

threshold violation.<br />

iemHighHumidThresholdViol<br />

ationCleared<br />

APC IEM: High humidity<br />

threshold violation cleared.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

155 INFORMAT<br />

IONAL<br />

A Fuse/CB alarm is no longer active in<br />

the DC power plant.<br />

156 WARNING A Battery Test failed in the DC power<br />

plant.<br />

157 WARNING A Temperature alarm is active in the<br />

power plant.<br />

158 INFORMAT<br />

IONAL<br />

A Temperature alarm is no longer active<br />

in the power plant.<br />

159 WARNING A Humidity alarm is active in the DC<br />

power plant.<br />

160 INFORMAT<br />

IONAL<br />

161 INFORMAT<br />

IONAL<br />

A Humidity alarm is no longer active in<br />

the DC power plant.<br />

Power plant bridging board<br />

communications established.<br />

162 MAJOR Power plant bridging board<br />

communications lost.<br />

163 MAJOR High temperature threshold violation.<br />

164 INFORMAT<br />

IONAL<br />

High temperature threshold violation has<br />

been cleared.<br />

165 MAJOR Low temperature threshold violation.<br />

166 INFORMAT<br />

IONAL<br />

Low temperature threshold violation has<br />

been cleared.<br />

167 MAJOR High humidity threshold violation.<br />

168 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

High humidity threshold violation has<br />

been cleared.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

iemLowHumidThresholdViola<br />

tion<br />

APC IEM: Low humidity<br />

threshold violation.<br />

iemLowHumidThresholdViola<br />

tionCleared<br />

APC IEM: Low humidity<br />

threshold violation cleared.<br />

iemProbeDisconnected<br />

APC IEM: Probe<br />

disconnected.<br />

iemProbeConnected<br />

APC IEM: Probe Connected.<br />

iemContactFault<br />

APC IEM: Contact fault.<br />

iemContactFaultCleared<br />

APC IEM: Contact fault.<br />

iemRelayFault<br />

APC IEM: Output relay fault.<br />

iemRelayFaultCleared<br />

APC IEM: Output relay fault<br />

condition cleared.<br />

bmBatManCommEstab<br />

BatMan : Communications<br />

Established.<br />

bmBatManCommLost<br />

BatMan : Communications<br />

Lost.<br />

bmBatManKneeAlarm<br />

BatMan : Knee Alarm<br />

Detected.<br />

bmBatManKneeAlarmCleared<br />

BatMan : Knee Alarm<br />

Cleared.<br />

bmBatManChargerAlarm<br />

BatMan : Charger Alarm<br />

Detected.<br />

bmBatManChargerAlarmClea<br />

red<br />

BatMan : Charger Alarm<br />

Cleared.<br />

bmBatManBatteryAlarm<br />

BatMan : Battery Alarm<br />

Detected.<br />

bmBatManBatteryAlarmClear<br />

ed<br />

BatMan : Battery Alarm<br />

Cleared.<br />

bmBatManEnvironmentAlarm<br />

BatMan : Environment Alarm<br />

Detected.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

169 MAJOR Low humidity threshold violation.<br />

170 INFORMAT<br />

IONAL<br />

Low humidity threshold violation has<br />

been cleared.<br />

171 WARNING Probe has been disconnected.<br />

172 INFORMAT<br />

IONAL<br />

Probe has been connected.<br />

173 MAJOR Contact fault.<br />

174 INFORMAT<br />

IONAL<br />

Contact fault cleared.<br />

175 MAJOR Output relay has faulted.<br />

176 INFORMAT<br />

IONAL<br />

177 INFORMAT<br />

IONAL<br />

Output relay fault cleared.<br />

Communications Established.<br />

178 MAJOR Communications Lost.<br />

179 MAJOR Knee Alarm Detected.<br />

180 INFORMAT<br />

IONAL<br />

Knee Alarm Cleared.<br />

181 WARNING Charger Alarm Detected.<br />

182 INFORMAT<br />

IONAL<br />

Charger Alarm Cleared.<br />

183 WARNING Battery Alarm Detected.<br />

184 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Battery Alarm Cleared.<br />

185 WARNING Environment Alarm Detected.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

69


70<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

bmBatManEnvironmentAlarm<br />

Cleared<br />

BatMan : Environment Alarm<br />

Cleared.<br />

bmBatManMaintenanceAlarm<br />

BatMan : Maintenance Due<br />

Alarm Detected.<br />

bmBatManMaintenanceAlarm<br />

Cleared<br />

BatMan : Maintenance Due<br />

Alarm Cleared.<br />

pduCommunicationEstablished<br />

APC PDU: Communication<br />

Established.<br />

pduCommunicationLost<br />

APC PDU: Communication<br />

Lost.<br />

pduUtilityLineUndervoltage<br />

APC PDU: Utility Line<br />

Undervoltage.<br />

pduUtilityLineUndervoltageCl<br />

eared<br />

APC PDU: Utility Line<br />

Undervoltage Cleared.<br />

pduUtilityLineOvervoltage<br />

APC PDU: Utility Line<br />

Overvoltage.<br />

pduUtilityLineOvervoltageCle<br />

ared<br />

APC PDU: Utility Line<br />

Overvoltage Cleared.<br />

pduGroundOvercurrent<br />

APC PDU: Ground<br />

Overcurrent.<br />

pduGroundOvercurrentCleared<br />

APC PDU: Ground<br />

Overcurrent Cleared.<br />

pduCircuitPanelInputUndervo<br />

ltage<br />

APC PDU: Circuit Panel Input<br />

Undervoltage.<br />

pduCircuitPanelInputUndervo<br />

ltageCleared<br />

APC PDU: Circuit Panel Input<br />

Undervoltage Cleared.<br />

pduCircuitPanelInputOvervolt<br />

age<br />

APC PDU: Circuit Panel Input<br />

Overvoltage.<br />

pduCircuitPanelInputOvervolt<br />

ageCleared<br />

APC PDU: Circuit Panel Input<br />

Overvoltage Cleared.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

186 INFORMAT<br />

IONAL<br />

187 INFORMAT<br />

IONAL<br />

188 INFORMAT<br />

IONAL<br />

189 INFORMAT<br />

IONAL<br />

Environment Alarm Cleared.<br />

Maintenance Due Alarm Detected.<br />

Maintenance Due Alarm Cleared.<br />

Communication Established.<br />

190 MAJOR Communication Lost.<br />

191 MAJOR Utility Line Undervoltage.<br />

192 INFORMAT<br />

IONAL<br />

Utility Line Undervoltage Cleared.<br />

193 MAJOR Utility Line Overvoltage.<br />

194 INFORMAT<br />

IONAL<br />

Utility Line Overvoltage Cleared.<br />

195 MAJOR Ground Overcurrent.<br />

196 INFORMAT<br />

IONAL<br />

Ground Overcurrent Cleared.<br />

197 MAJOR Circuit Panel Input Undervoltage.<br />

198 INFORMAT<br />

IONAL<br />

Circuit Panel Input Undervoltage<br />

Cleared.<br />

199 MAJOR Circuit Panel Input Overvoltage.<br />

200 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Circuit Panel Input Overvoltage Cleared.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

pduCircuitPanelInputUndercu<br />

rrent<br />

APC PDU: Circuit Panel Input<br />

Undercurrent.<br />

pduCircuitPanelInputUndercu<br />

rrentCleared<br />

APC PDU: Circuit Panel Input<br />

Undercurrent Cleared.<br />

pduCircuitPanelInputOvercurr<br />

ent<br />

APC PDU: Circuit Panel Input<br />

Overcurrent.<br />

pduCircuitPanelInputOvercurr<br />

entCleared<br />

APC PDU: Circuit Panel Input<br />

Overcurrent Cleared.<br />

pduCircuitPanelFrequencyOut<br />

OfRange<br />

APC PDU: Circuit Panel Input<br />

Frequency Out Of Range.<br />

pduCircuitPanelFrequencyOut<br />

ofRangeCleared<br />

APC PDU: Circuit Panel Input<br />

Frequency No Longer Out Of<br />

Range.<br />

pduCircuitPanelNeutralOverc<br />

urrent<br />

APC PDU: Circuit Panel Input<br />

Neutral Overcurrent.<br />

pduCircuitPanelNeutralOverc<br />

urrentCleared<br />

APC PDU: Circuit Panel Input<br />

Neutral Overcurrent Cleared.<br />

pduSystemOff<br />

APC PDU: System Off.<br />

pduOnBatteryMode<br />

APC PDU: On Battery Mode.<br />

pduMaintenanceBypassMode<br />

APC PDU: Maintenance<br />

Bypass Mode.<br />

pduAtypicalBypassMode<br />

APC PDU: Atypical Bypass<br />

Mode.<br />

pduNoPanelFeedMode<br />

APC PDU: No Panel Feed<br />

Mode.<br />

pduUpsOperationMode<br />

APC PDU: Ups Operation<br />

Mode.<br />

pduForcedBypassMode<br />

APC PDU: Forced Bypass<br />

Mode.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

201 MAJOR Circuit Panel Input Undercurrent.<br />

202 INFORMAT<br />

IONAL<br />

Circuit Panel Input Undercurrent<br />

Cleared.<br />

203 MAJOR Circuit Panel Input Overcurrent.<br />

204 INFORMAT<br />

IONAL<br />

Circuit Panel Input Overcurrent Cleared.<br />

205 MAJOR Circuit Panel Input Frequency Out Of<br />

Range.<br />

206 INFORMAT<br />

IONAL<br />

Circuit Panel Input Frequency No Longer<br />

Out Of Range.<br />

207 MAJOR Circuit Panel Input Neutral Overcurrent.<br />

208 INFORMAT<br />

IONAL<br />

209 MAJOR PDU System Off.<br />

Circuit Panel Input Neutral Overcurrent<br />

Cleared.<br />

210 MAJOR PDU is in On Battery Mode.<br />

211 INFORMAT<br />

IONAL<br />

PDU is in Maintenance Bypass Mode.<br />

212 WARNING PDU is in Atypical Bypass Mode.<br />

213 MAJOR PDU is in No Panel Feed Mode.<br />

214 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

PDU is in Ups Operation Mode.<br />

215 WARNING PDU is in Forced Bypass Mode.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

71


72<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

pduInputTransformerOverTem<br />

perature<br />

APC PDU: Input Transformer<br />

Over Temperature.<br />

pduInputTransformerOverTem<br />

peratureCleared<br />

APC PDU: Input Transformer<br />

Over Temperature Cleared.<br />

pduUPSInputVoltageLost<br />

APC PDU: UPS Input Voltage<br />

phase-N Lost.<br />

pduUPSInputVoltageRestored<br />

APC PDU: UPS Input Voltage<br />

phase-N Restored.<br />

pduContactFault<br />

APC PDU: Contact Abnormal.<br />

pduContactFaultCleared<br />

APC PDU: Contact Normal.<br />

rmPDUUndercurrent<br />

APC RM PDU: Undercurrent.<br />

rmPDUUndercurrentCleared<br />

APC RM PDU: Undercurrent<br />

Cleared.<br />

rmPDUOvercurrent<br />

APC RM PDU: Overcurrent.<br />

rmPDUOvercurrentCleared<br />

APC RM PDU: Overcurrent<br />

Cleared.<br />

rmPDUOverload<br />

APC RM PDU: Overload.<br />

rmPDUOverloadCleared<br />

APC RM PDU: Overload<br />

Cleared.<br />

rmPDUCommunicationEstabli<br />

shed<br />

APC RM PDU:<br />

Communication Established.<br />

rmPDUCommunicationLost<br />

APC RM PDU:<br />

Communication Lost.<br />

emsCommunicationEstablished<br />

APC EMS: Communication<br />

Established.<br />

emsCommunicationLost<br />

APC EMS: Communication<br />

Lost.<br />

emsProbeConnected<br />

APC EMS: Probe Connected.<br />

emsProbeDisconnected<br />

APC EMS: Probe<br />

Disconnected.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

216 MAJOR Input Transformer Over Temperature.<br />

217 INFORMAT<br />

IONAL<br />

Input Transformer Over Temperature<br />

Cleared.<br />

218 MAJOR UPS Input Voltage phase-N Lost.<br />

219 INFORMAT<br />

IONAL<br />

UPS Input Voltage phase-N Restored.<br />

220 MAJOR Contact Abnormal.<br />

221 INFORMAT<br />

IONAL<br />

Contact Normal.<br />

222 MAJOR Undercurrent.<br />

223 INFORMAT<br />

IONAL<br />

Undercurrent Cleared.<br />

224 MAJOR Overcurrent.<br />

225 INFORMAT<br />

IONAL<br />

226 MAJOR Overload.<br />

227 INFORMAT<br />

IONAL<br />

228 INFORMAT<br />

IONAL<br />

Overcurrent Cleared.<br />

Overload Cleared.<br />

Communication Established.<br />

229 MAJOR Communication Lost.<br />

230 INFORMAT<br />

IONAL<br />

Communication Established.<br />

231 MAJOR Communication Lost.<br />

232 INFORMAT<br />

IONAL<br />

Probe Connected.<br />

233 MAJOR Probe Disconnected.<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

emsSensorConnected<br />

APC EMS: Sensor Connected.<br />

emsSensorDisconnected<br />

APC EMS: Sensor<br />

Disconnected.<br />

emsSensorFault<br />

APC EMS: Sensor Fault.<br />

emsSensorFaultCleared<br />

APC EMS: Sensor Fault<br />

Cleared.<br />

emsBeaconConnected<br />

APC EMS: Beacon<br />

Connected.<br />

emsBeaconDisconnected<br />

APC EMS: Beacon<br />

Disconnected.<br />

emsBeaconOn<br />

APC EMS: Beacon On.<br />

emsBeaconOff<br />

APC EMS: Beacon Off.<br />

emsMajorAlarm<br />

APC EMS: Major Alarm.<br />

emsMajorAlarmCleared<br />

APC EMS: Major Alarm<br />

Cleared.<br />

emsMinorAlarm<br />

APC EMS: Minor Alarm.<br />

emsMinorAlarmCleared<br />

APC EMS: Minor Alarm<br />

Cleared.<br />

emsOutletStateAbnormal<br />

APC EMS: Outlet has changed<br />

to its abnormal state.<br />

emsOutletStateNormal<br />

APC EMS: Outlet has changed<br />

to its normal state.<br />

emsInputContactStateAbnorm<br />

al<br />

APC EMS: Input contact has<br />

changed to its abnormal state.<br />

emsInputContactStateNormal<br />

APC EMS: Input contact has<br />

changed to its normal state.<br />

emsOutputRelayStateAbnorm<br />

al<br />

APC EMS: Output Relay has<br />

changed to its abnormal state.<br />

emsOutputRelayStateNormal<br />

APC EMS: Output Relay has<br />

changed to its normal state.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

234 INFORMAT<br />

IONAL<br />

Sensor Connected.<br />

235 MAJOR Sensor Disconnected.<br />

236 MAJOR Sensor Fault.<br />

237 INFORMAT<br />

IONAL<br />

238 INFORMAT<br />

IONAL<br />

Sensor Fault Cleared.<br />

Beacon Connected.<br />

239 MAJOR Beacon Disconnected.<br />

240 INFORMAT<br />

IONAL<br />

241 INFORMAT<br />

IONAL<br />

Beacon On.<br />

Beacon Off.<br />

242 MAJOR Major Alarm.<br />

243 INFORMAT<br />

IONAL<br />

Major Alarm Cleared.<br />

244 MAJOR Minor Alarm.<br />

245 INFORMAT<br />

IONAL<br />

Minor Alarm Cleared.<br />

246 WARNING Outlet has changed to its abnormal state.<br />

247 INFORMAT<br />

IONAL<br />

Outlet has changed to its normal state.<br />

248 WARNING Input contact has changed to its abnormal<br />

state.<br />

249 INFORMAT<br />

IONAL<br />

Input contact has changed to its normal<br />

state.<br />

250 WARNING Output Relay has changed to its<br />

abnormal state.<br />

251 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Output Relay has changed to its normal<br />

state.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

73


74<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

emsDeviceConfigChange<br />

APC: A device configuration<br />

change on a EMS.<br />

envHighTempThresholdViolat<br />

ion<br />

APC ENV: High temperature<br />

threshold violation.<br />

envHighTempThresholdViolat<br />

ionCleared<br />

APC ENV: High temperature<br />

threshold violation cleared.<br />

envLowTempThresholdViolati<br />

on<br />

APC ENV: Low temperature<br />

threshold violation.<br />

envLowTempThresholdViolati<br />

onCleared<br />

APC ENV: Low temperature<br />

threshold violation cleared.<br />

envHighHumidityThresholdVi<br />

olation<br />

APC ENV: High humidity<br />

threshold violation.<br />

envHighHumidityThresholdVi<br />

olationCleared<br />

APC ENV: High humidity<br />

threshold violation cleared.<br />

envLowHumidityThresholdVi<br />

olation<br />

APC ENV: Low humidity<br />

threshold violation.<br />

envLowHumidityThresholdVi<br />

olationCleared<br />

APC ENV: Low humidity<br />

threshold violation cleared.<br />

rPDUCommunicationEstablis<br />

hed<br />

APC Rack PDU:<br />

Communication established.<br />

rPDUCommunicationLost<br />

APC Rack PDU:<br />

Communication lost.<br />

rPDUOutletOn<br />

APC Switched Rack PDU: An<br />

outlet has turned on.<br />

rPDUOutletOff<br />

APC Switched Rack PDU: An<br />

outlet has turned off.<br />

rPDUDeviceConfigChange<br />

APC Rack PDU: Device<br />

configuration change made.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

252 INFORMAT<br />

IONAL<br />

A device configuration change has been<br />

made on a EMS.<br />

253 MAJOR High temperature threshold violation.<br />

254 INFORMAT<br />

IONAL<br />

High temperature threshold violation<br />

cleared.<br />

255 MAJOR Low temperature threshold violation.<br />

256 INFORMAT<br />

IONAL<br />

Low temperature threshold violation<br />

cleared.<br />

257 MAJOR High humidity threshold violation.<br />

258 INFORMAT<br />

IONAL<br />

High humidity threshold violation<br />

cleared.<br />

259 MAJOR Low humidity threshold violation.<br />

260 INFORMAT<br />

IONAL<br />

266 INFORMAT<br />

IONAL<br />

Low humidity threshold violation<br />

cleared.<br />

Communication with a Rack PDU<br />

established.<br />

267 MAJOR Communication with a Rack PDU has<br />

been lost.<br />

268 INFORMAT<br />

IONAL<br />

269 INFORMAT<br />

IONAL<br />

270 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

An outlet on a Switched Rack PDU has<br />

turned on.<br />

An outlet on a Switched Rack PDU has<br />

turned off.<br />

Device configuration change has been<br />

made on a Rack PDU.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

rPDUOutletConfigChange<br />

APC Switched Rack PDU:<br />

Outlet configuration change<br />

made.<br />

rPDULowLoad<br />

APC Rack PDU: Violation of<br />

low load threshold.<br />

rPDULowLoadCleared<br />

APC Rack PDU: Low load<br />

condition cleared.<br />

rPDUNearOverload<br />

APC Rack PDU: Near an<br />

overload condition.<br />

rPDUNearOverloadCleared<br />

APC Rack PDU: Near<br />

overload condition has<br />

cleared.<br />

rPDUOverload<br />

APC Rack PDU: Overload<br />

condition.<br />

rPDUOverloadCleared<br />

APC Rack PDU: Overload<br />

condition has cleared.<br />

rPDUPowerSupply1Fail<br />

APC Rack PDU: Power<br />

Supply 1 is in FAIL state.<br />

rPDUPowerSupply1Ok<br />

APC Rack PDU: Power<br />

Supply 1 is operating<br />

normally.<br />

rPDUPowerSupply2Fail<br />

APC Rack PDU: Power<br />

Supply 2 is in FAIL state.<br />

rPDUPowerSupply2Ok<br />

APC Rack PDU: Power<br />

Supply 2 is operating<br />

normally.<br />

rPDUPhaseConfigChange<br />

APC Rack PDU: Phase<br />

configuration change made.<br />

rPDUCancelPendingCommand<br />

APC Switched Rack PDU:<br />

Cancel Pending Command<br />

made.<br />

aruAlinkCommunicationEstab<br />

lished<br />

APC ARU: Communication<br />

Established.<br />

aruAlinkCommunicationLost<br />

APC ARU: Communication<br />

Lost.<br />

aruFanFail<br />

APC ARU: Fan Fail.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

271 INFORMAT<br />

IONAL<br />

Outlet configuration change has been<br />

made on a Switched Rack PDU.<br />

272 WARNING A Rack PDU has violated the low load<br />

threshold.<br />

273 INFORMAT<br />

IONAL<br />

The low load condition on a Rack PDU<br />

has been cleared.<br />

274 WARNING A Rack PDU is near an overload<br />

condition.<br />

275 INFORMAT<br />

IONAL<br />

Rack PDU near overload condition has<br />

cleared.<br />

276 MAJOR A Rack PDU is in an overload condition.<br />

277 INFORMAT<br />

IONAL<br />

The overload condition on a Rack PDU<br />

has cleared.<br />

278 MAJOR Power Supply 1 on Rack PDU is in FAIL<br />

state.<br />

279 INFORMAT<br />

IONAL<br />

Power Supply 1 on Rack PDU is<br />

operating normally.<br />

280 MAJOR Power Supply 2 on Rack PDU is in FAIL<br />

state.<br />

281 INFORMAT<br />

IONAL<br />

282 INFORMAT<br />

IONAL<br />

283 INFORMAT<br />

IONAL<br />

284 INFORMAT<br />

IONAL<br />

Power Supply 2 on Rack PDU is<br />

operating normally.<br />

Phase configuration change has been<br />

made on a Rack PDU.<br />

A Cancel Pending Command has been<br />

made on a Switched Rack PDU.<br />

Communication Established.<br />

285 MAJOR Communication Lost.<br />

286 MAJOR Fan Fail.<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

75


76<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

aruFanFailCleared<br />

APC ARU: Fan Fail Cleared.<br />

aruSmokeAlarm<br />

APC ARU: Smoke Alarm.<br />

aruSmokeAlarmCleared<br />

APC ARU: Smoke Alarm<br />

Cleared.<br />

aruHighTemperatureAlarm<br />

APC ARU: High Temperature<br />

Alarm.<br />

aruHighTemperatureAlarmCle<br />

ared<br />

APC ARU: High Temperature<br />

Alarm Cleared.<br />

aruExhaustTemperatureAlarm<br />

APC ARU: Exhaust<br />

Temperature Alarm.<br />

aruExhaustTemperatureAlarm<br />

Cleared<br />

APC ARU: Exhaust<br />

Temperature Alarm Cleared.<br />

envAlinkCommunicationEsta<br />

blished<br />

APC ENV: Communication<br />

Established.<br />

envAlinkCommunicationLost<br />

APC ENV: Communication<br />

Lost.<br />

emsAlinkPowerOverload<br />

APC EMS: Alink Power<br />

Overload.<br />

emsAlinkPowerOverloadClear<br />

ed<br />

APC EMS: Alink Power<br />

Overload Cleared.<br />

upsOutletGroupTurnedOn<br />

APC UPS: Outlet Group<br />

turned on.<br />

upsOutletGroupTurnedOff<br />

APC UPS: Outlet Group<br />

turned off.<br />

smwCriticalCondition<br />

APC Symmetra MW UPS: A<br />

critical condition has been<br />

detected.<br />

smwCriticalConditionCleared<br />

APC Symmetra MW UPS: A<br />

critical condition has been<br />

cleared.<br />

smwWarningCondition<br />

APC Symmetra MW UPS: A<br />

warning condition has been<br />

detected.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

287 INFORMAT<br />

IONAL<br />

Fan Fail Cleared.<br />

288 MAJOR Smoke Alarm.<br />

289 INFORMAT<br />

IONAL<br />

Smoke Alarm Cleared.<br />

290 MAJOR High Temperature Alarm.<br />

291 INFORMAT<br />

IONAL<br />

High Temperature Alarm Cleared.<br />

292 MAJOR Exhaust Temperature Alarm.<br />

293 INFORMAT<br />

IONAL<br />

294 INFORMAT<br />

IONAL<br />

Exhaust Temperature Alarm Cleared.<br />

Communication Established.<br />

295 MAJOR Communication Lost.<br />

296 MAJOR Alink Power Overload.<br />

297 INFORMAT<br />

IONAL<br />

298 INFORMAT<br />

IONAL<br />

Alink Power Overload Cleared.<br />

Outlet Group turned on<br />

299 WARNING Outlet Group turned off.<br />

300 MAJOR A critical condition has been detected.<br />

301 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A critical condition has been cleared.<br />

302 WARNING A warning condition has been detected.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

smwWarningConditionCleared<br />

APC Symmetra MW UPS: A<br />

warning condition has been<br />

cleared.<br />

smwInformationalCondition<br />

APC Symmetra MW UPS:<br />

Informational condition<br />

detected.<br />

smwInformationalConditionCl<br />

eared<br />

APC Symmetra MW UPS:<br />

Informational condition<br />

cleared.<br />

airCriticalCondition<br />

APC Air: A critical condition<br />

was detected.<br />

airCriticalConditionCleared<br />

APC Air: A critical condition<br />

was cleared.<br />

airWarningCondition<br />

APC Air: A warning condition<br />

was detected.<br />

airWarningConditionCleared<br />

APC Air: A warning condition<br />

was cleared.<br />

airInformationalCondition<br />

APC Air: Informational<br />

condition detected.<br />

airInformationalConditionCle<br />

ared<br />

APC Air: Informational<br />

condition was cleared.<br />

xPDUThreePhaseInputVoltage<br />

Alarm<br />

APC PDU: Main input voltage<br />

out-of-range alarm.<br />

xPDUThreePhaseInputVoltage<br />

Normal<br />

APC PDU: Main input voltage<br />

back in range.<br />

xPDUThreePhaseBypassVolta<br />

geAlarm<br />

APC PDU: Bypass input<br />

voltage out-of-range alarm.<br />

xPDUThreePhaseBypassVolta<br />

geNormal<br />

APC PDU: Bypass input<br />

voltage back in range.<br />

xPDUThreePhaseOutputVolta<br />

geAlarm<br />

APC PDU: Output voltage<br />

out-of-range alarm.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

303 INFORMAT<br />

IONAL<br />

304 INFORMAT<br />

IONAL<br />

305 INFORMAT<br />

IONAL<br />

A warning condition has been cleared.<br />

An informational condition has been<br />

detected.<br />

An informational condition has been<br />

cleared.<br />

306 MAJOR A critical condition was detected.<br />

307 INFORMAT<br />

IONAL<br />

A critical condition was cleared.<br />

308 WARNING A warning condition was detected.<br />

309 INFORMAT<br />

IONAL<br />

310 INFORMAT<br />

IONAL<br />

311 INFORMAT<br />

IONAL<br />

A warning condition was cleared.<br />

An informational condition was detected.<br />

An informational condition was cleared.<br />

312 MAJOR Input voltage is out-of-range.<br />

313 INFORMAT<br />

IONAL<br />

Input voltage in range.<br />

314 MAJOR Bypass input voltage is out-of-range.<br />

315 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Bypass input voltage in range.<br />

316 MAJOR Output voltage is out-of-range.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

77


78<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

xPDUThreePhaseOutputVolta<br />

geNormal<br />

APC PDU: Output voltage<br />

back in range.<br />

xPDUThreePhaseOutputCurre<br />

ntAlarm<br />

APC PDU: Output (load)<br />

current out-of-range alarm.<br />

xPDUThreePhaseOutputCurre<br />

ntNormal<br />

APC PDU: Output (load)<br />

current back in range.<br />

xPDUOutputFrequencyAlarm<br />

APC PDU: Output frequency<br />

out-of-range alarm.<br />

xPDUOutputFrequencyNormal<br />

APC PDU: Output frequency<br />

back in range.<br />

xPDUSystemGroundCurrentA<br />

larm<br />

APC PDU: Earth ground<br />

current over range alarm.<br />

xPDUSystemGroundCurrentN<br />

ormal<br />

APC PDU: Earth ground<br />

current back in range.<br />

xPDUInputContactStateAbnor<br />

mal<br />

APC PDU: Input contact has<br />

changed to its abnormal state.<br />

xPDUInputContactStateNorm<br />

al<br />

APC PDU: Input contact has<br />

changed to its normal state.<br />

xPDUOutputRelayStateAbnor<br />

mal<br />

APC PDU: Output Relay has<br />

changed to its abnormal state.<br />

xPDUOutputRelayStateNorm<br />

al<br />

APC PDU: Output Relay has<br />

changed to its normal state.<br />

xPDUCoolingFanAlarm<br />

APC PDU: Cooling fan failure<br />

alarm.<br />

xPDUCoolingFanAlarmClear<br />

ed<br />

APC PDU: Cooling fan alarm<br />

cleared.<br />

xPDUTransformerTempAlarm<br />

APC PDU: Isolation<br />

transformer over temperature<br />

alarm.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

317 INFORMAT<br />

IONAL<br />

Output voltage in range.<br />

318 MAJOR Output current is out-of-range.<br />

319 INFORMAT<br />

IONAL<br />

Output current in range.<br />

320 MAJOR Output frequency is out-of-range.<br />

321 INFORMAT<br />

IONAL<br />

Output frequency in range.<br />

322 MAJOR Earth ground current is over limit.<br />

323 INFORMAT<br />

IONAL<br />

Earth ground current in range.<br />

324 WARNING Input contact has changed to its abnormal<br />

state.<br />

325 INFORMAT<br />

IONAL<br />

Input contact has changed to its normal<br />

state.<br />

326 WARNING Output Relay has changed to its<br />

abnormal state.<br />

327 INFORMAT<br />

IONAL<br />

Output Relay has changed to its normal<br />

state.<br />

328 MAJOR Cooling fan failure.<br />

329 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Cooling fan alarm cleared.<br />

330 MAJOR Transformer temp alarm.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

xPDUTransformerTempAlarm<br />

Cleared<br />

APC PDU: Isolation<br />

transformer over temperature<br />

alarm cleared.<br />

xPDUBranchCurrentAlarm<br />

APC PDU: Branch circuit<br />

current out-of-range alarm.<br />

xPDUBranchCurrentNormal<br />

APC PDU: Branch circuit<br />

current back in range.<br />

xPDUBreakerChangeEvent<br />

APC PDU: Breaker/switch<br />

change event.<br />

xPDUInternalCommError<br />

APC PDU: Internal<br />

communication error.<br />

xPDUInternalCommEstablish<br />

ed<br />

APC PDU: Internal<br />

Communication established.<br />

xPDUSystemStateAlarm<br />

APC PDU: System state alarm.<br />

xPDUSystemStateNormal<br />

APC PDU: System state<br />

returned to normal.<br />

xPDUEpoTestMode<br />

APC PDU: Emergency Power<br />

Off (EPO) in test mode.<br />

xPDUEpoArmed<br />

APC PDU: Emergency Power<br />

Off (EPO) enabled.<br />

xPDUFuseBlownAlarm<br />

APC PDU: Check fuse alarm.<br />

xPDUFuseBlownAlarmCleared<br />

APC PDU: Check fuse alarm<br />

cleared.<br />

xPDUBreakerPositionAlarm<br />

APC PDU: Breaker position<br />

alarm.<br />

xPDUBreakerPositionAlarmC<br />

leared<br />

APC PDU: Breaker position<br />

alarm cleared.<br />

table: PowerNet-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.318)<br />

Specific<br />

Level of<br />

importance<br />

331 INFORMAT<br />

IONAL<br />

Transformer temp alarm cleared.<br />

332 MAJOR Branch circuit current is out-of-range.<br />

333 INFORMAT<br />

IONAL<br />

334 INFORMAT<br />

IONAL<br />

Branch circuit current in range.<br />

Breaker/switch change event.<br />

335 MAJOR Internal communication error.<br />

336 INFORMAT<br />

IONAL<br />

Communication established.<br />

337 WARNING PDU state alarm.<br />

338 INFORMAT<br />

IONAL<br />

PDU state normal.<br />

339 WARNING EPO disabled.<br />

340 INFORMAT<br />

IONAL<br />

EPO armed.<br />

341 MAJOR Fuse detected opened.<br />

342 INFORMAT<br />

IONAL<br />

Fuse alarm cleared.<br />

343 MAJOR Breaker position alarm.<br />

344 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Breaker alarm cleared.<br />

B.23 PowerNet-MIB (powernet.mib)<br />

Remarks<br />

79


80<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.24 Alert-Definition-Originator-MIB (F5emt2o.mib)<br />

<strong>Trap</strong>s from Fujitsu LDSM. Refer to the LDSM manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

ldsm<strong>Trap</strong>-Monitored<br />

LDSM Monitored Event<br />

ldsm<strong>Trap</strong>-Informational<br />

LDSM Informational Event<br />

ldsm<strong>Trap</strong>-Recovered<br />

LDSM Recovered Event<br />

ldsm<strong>Trap</strong>-NonCritical<br />

LDSM NonCritical Event<br />

ldsm<strong>Trap</strong>-Critical<br />

LDSM Critical Event<br />

ldsm<strong>Trap</strong>-NonRecoverable<br />

LDSM NonRecoverable Event<br />

table: Alert-Definition-Originator-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.211.4.1.4.6)<br />

Specific<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

4 INFORMAT<br />

IONAL<br />

8 INFORMAT<br />

IONAL<br />

16 INFORMAT<br />

IONAL<br />

32 INFORMAT<br />

IONAL<br />

B.25 LDSM-MIB (ldsm.mib)<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

LDSM has reported: %s %s %s %s<br />

LDSM has reported: %s %s %s %s<br />

LDSM has reported: %s %s %s %s<br />

LDSM has reported: %s %s %s %s<br />

LDSM has reported: %s %s %s %s<br />

LDSM has reported: %s %s %s %s<br />

<strong>Trap</strong>s from Fujitsu LDSM. Refer to the LDSM manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

ldsmOK<strong>Trap</strong><br />

Intel LANDeskÆ Server<br />

Manager has reported a status<br />

OK event.<br />

ldsmInformational<strong>Trap</strong><br />

Intel LANDeskÆ Server<br />

Manager has reported a status<br />

Informational event.<br />

ldsmWarning<strong>Trap</strong><br />

Intel LANDeskÆ Server<br />

Manager has reported a status<br />

Warning event.<br />

dsmCritical<strong>Trap</strong><br />

Intel LANDeskÆ Server<br />

Manager has reported a status<br />

Critical event.<br />

table: LDSM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises343.2.5.1.3)<br />

Specific<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Intel LANDeskÆ Server Manager has<br />

reported: The computer's status is %s.<br />

Intel LANDeskÆ Server Manager has<br />

reported: The computer's status is %s.<br />

3 MINOR Intel LANDeskÆ Server Manager has<br />

reported: The computer's status is %s.<br />

4 CRITICAL Intel LANDeskÆ Server Manager has<br />

reported: The computer's status is %s.<br />

Remarks<br />

Remarks


B.26 LDCM-MIB (Ldcm.mib)<br />

<strong>Trap</strong>s from Fujitsu LDSM. Refer to the LDSM manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

ldcmUnknown<strong>Trap</strong><br />

IntelÆ LANDeskÆ Client<br />

Manager has reported an<br />

Unknown event.<br />

ldcmInfo<strong>Trap</strong><br />

IntelÆ LANDeskÆ Client<br />

Manager has reported an<br />

Informational event.<br />

ldcmOk<strong>Trap</strong><br />

IntelÆ LANDeskÆ Client<br />

Manager has reported a<br />

severity OK event.<br />

ldcmWarning<strong>Trap</strong><br />

IntelÆ LANDeskÆ Client<br />

Manager has reported a<br />

severity Warning event.<br />

ldcmCritical<strong>Trap</strong><br />

IntelÆ LANDeskÆ Client<br />

Manager has reported a<br />

severity Critical event.<br />

ldcmFatal<strong>Trap</strong><br />

IntelÆ LANDeskÆ Client<br />

Manager has reported a<br />

severity Fatal event.<br />

table: LDCM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises343.2.5.1.2)<br />

Specific<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

3 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Client Manager has reported an event on<br />

the computer %s: %s<br />

Client Manager has reported an event on<br />

the computer %s: %s<br />

Client Manager has reported an event on<br />

the computer %s: %s<br />

4 MINOR Client Manager has reported an event on<br />

the computer %s: %s<br />

5 CRITICAL Client Manager has reported an event on<br />

the computer %s: %s<br />

6 CRITICAL Client Manager has reported an event on<br />

the computer %s: %s<br />

B.26 LDCM-MIB (Ldcm.mib)<br />

Remarks<br />

81


82<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.27 FUJITSU-SERVERVISOR-MIB (Servervi.mib)<br />

<strong>Trap</strong>s from Fujitsu Severvisor. Refer to the Servervisor manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

svisor<strong>Trap</strong>Type<br />

Servervisor Event<br />

table: FUJITSU-SERVERVISOR-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.211.4.36.1.1.1)<br />

Specific<br />

Level of<br />

importance<br />

32 INFORMAT<br />

IONAL<br />

B.28 RFC1157 (RFC1157.mib)<br />

<strong>Trap</strong>s from RFC1157. Refer to the RFC1157 manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

rfc1157ColdStart<br />

Cold start<br />

rfc1157WarmStart<br />

Warm start<br />

rfc1157LinkDown<br />

Link down<br />

rfc1157LinkUp<br />

Link up<br />

rfc1157AuthenticationFailure<br />

Authentication failure<br />

rfc1157EGPNeighborLost<br />

EGP neighbor lost<br />

B.29 ROMPILOT-MIB (ROMPILOT.MIB)<br />

<strong>Trap</strong>s from ROM PILOT (phoenix BIOS).<br />

TRAP-TYPE/<br />

Alarm type<br />

rpWarmReset<strong>Trap</strong><br />

RomPilot Warm Reset <strong>Trap</strong>.<br />

rpColdReset<strong>Trap</strong><br />

RomPilot Cold Reset <strong>Trap</strong>.<br />

rpDiagReset<strong>Trap</strong><br />

RomPilot Diagnostic Reset<br />

<strong>Trap</strong>.<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Servervisor has reported: %s<br />

table: RFC1157(Microsoft) <strong>Trap</strong> (ENTERPRISE : enterprises.311.1.1.3.1.x)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks<br />

Remarks<br />

0 MINOR Station reinitialized. SNMP service started.<br />

0 MINOR Station reinitialized. SNMP service<br />

restarted.<br />

0 CRITICAL Communication link failed at the station<br />

%d.<br />

0 MINOR Communication link restored at the<br />

station %d.<br />

Interface failed.<br />

Interface restored.<br />

0 MINOR Unauthorized message received. An SNMP request<br />

packet was received<br />

from an unauthorized<br />

community.<br />

0 MAJOR Neighboring station down.<br />

table: ROMPILOT-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.2487)<br />

Specific<br />

Level of<br />

importance<br />

257 INFORMAT<br />

IONAL<br />

258 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

RomPilot machine %s with MAC<br />

address %m has performed a warm reset<br />

and is running the BIOS POST.<br />

RomPilot machine %s with MAC<br />

address %m has performed a cold reset<br />

and is running the BIOS POST.<br />

259 MINOR RomPilot machine %s with MAC<br />

address %m has performed a diagnostic<br />

reset and is running the BIOS POST.<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

rpIDEReset<strong>Trap</strong><br />

RomPilot IDE disk Reset<br />

<strong>Trap</strong>.<br />

rpBoot<strong>Trap</strong><br />

RomPilot OS Boot <strong>Trap</strong>.<br />

rpPostFtlError<strong>Trap</strong><br />

RomPilot Fatal POST Error<br />

<strong>Trap</strong>.<br />

rpPostConError<strong>Trap</strong><br />

RomPilot Conditional POST<br />

Error <strong>Trap</strong>.<br />

rpPostWarng<strong>Trap</strong><br />

RomPilot Conditional POST<br />

Error <strong>Trap</strong>.<br />

rpSecurity<strong>Trap</strong><br />

RomPilot Security Breach<br />

<strong>Trap</strong>.<br />

rpNosUp<strong>Trap</strong><br />

RomPilot OS Loaded <strong>Trap</strong>.<br />

rpCritical<strong>Trap</strong><br />

RomPilot Critical <strong>Trap</strong>.<br />

rpDisconnect<strong>Trap</strong><br />

RomPilot Disconnect <strong>Trap</strong>.<br />

rpReconnect<strong>Trap</strong><br />

RomPilot Reconnect <strong>Trap</strong>.<br />

rpPostWarning<strong>Trap</strong><br />

RomPilot POST Warning<br />

<strong>Trap</strong>.<br />

rpPostConditional<strong>Trap</strong><br />

RomPilot Conditional POST<br />

Error <strong>Trap</strong>.<br />

rpPostFatal<strong>Trap</strong><br />

RomPilot Fatal POST Error<br />

<strong>Trap</strong>.<br />

table: ROMPILOT-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.2487)<br />

Specific<br />

Level of<br />

importance<br />

260 MINOR RomPilot machine %s with MAC<br />

address %m has performed an IDE disk<br />

reset and is running the BIOS POST.<br />

512 INFORMAT<br />

IONAL<br />

RomPilot machine %s with MAC<br />

address %m is starting to boot its<br />

Operating System.<br />

769 MAJOR RomPilot machine %s with MAC<br />

address %m has detected a fatal error<br />

during BIOS POST.<br />

770 MINOR RomPilot machine %s with MAC<br />

address %m has detected a conditional<br />

error during BIOS POST.<br />

771 MINOR RomPilot machine %s with MAC<br />

address %m has detected a conditional<br />

error during BIOS POST.<br />

1024 INFORMAT<br />

IONAL<br />

1280 INFORMAT<br />

IONAL<br />

RomPilot machine %s with MAC<br />

address %m has loaded its Operating<br />

System.<br />

RomPilot machine %s with MAC<br />

address %m has loaded its Operating<br />

System.<br />

1536 MAJOR RomPilot machine %s with MAC<br />

address %m has sent a critical trap.<br />

1792 INFORMAT<br />

IONAL<br />

2048 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

RomPilot machine %s with MAC<br />

address %m has sent a disconnect trap<br />

and will end communications abruptly.<br />

RomPilot machine %s with MAC<br />

address %m has sent a reconnect trap.<br />

This means that the RomPilot enabled<br />

machine is able to resume<br />

communications.<br />

16384 MINOR RomPilot machine %s with MAC<br />

address %m has detected a warning<br />

during BIOS POST.<br />

32768 MINOR RomPilot machine %s with MAC<br />

address %m has detected a conditional<br />

error during BIOS POST.<br />

49152 MAJOR RomPilot machine %s with MAC<br />

address %m has detected a fatal error<br />

during BIOS POST.<br />

B.29 ROMPILOT-MIB (ROMPILOT.MIB)<br />

Remarks<br />

83


84<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.30 SW-MIB (fcswitch.mib)<br />

<strong>Trap</strong>s from Fibre Channel Switch SN200. Refer to the SN200 manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

swFault<br />

Switch is faulty.<br />

swSensorScn<br />

A sensor (temperature, fan,<br />

etc.) changed its operational<br />

state.<br />

swFCPortScn<br />

A Fibre Channel Port changed<br />

its operational state.<br />

swEvent<strong>Trap</strong><br />

A firmware event has been<br />

logged<br />

swFabricWatch<strong>Trap</strong><br />

Fabric Watch has generated an<br />

event<br />

swTrackChanges<strong>Trap</strong><br />

Track changes has generated a<br />

trap<br />

table: SW-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.1588.2.1.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1 CRITICAL Faulty reason: %d<br />

2 INFORMAT<br />

IONAL<br />

3 INFORMAT<br />

IONAL<br />

4 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

%s: is currently in state %d<br />

Port Index %d changed state to %d<br />

Event %d: %s (severity level %d) - %s<br />

5 MINOR Threshold %s in Class/Area %d at index<br />

%d has generated event %d with %d on<br />

%s. This event is %d<br />

6 INFORMAT<br />

IONAL<br />

B.31 ADAPTECDURALINK-MIB (duralink.mib)<br />

%s<br />

Remarks<br />

<strong>Trap</strong>s from Duralink (Adaptec multiport adapter: 10Mbps/100Mbps multiport fast Ethernet network<br />

interface card).<br />

TRAP-TYPE/<br />

Alarm type<br />

duralinkStatus<strong>Trap</strong><br />

Port Status Changed<br />

duralinkPortUp<br />

Port Available<br />

duralinkPortDown<br />

Port Unavailable<br />

duralinkPortStandby<br />

Port acting as failover backup<br />

table: ADAPTECDURALINK-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.1588.2.1.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Group %d Port %d port status is %d.<br />

Group %s Port %s is up.<br />

3 MAJOR Group %s Port %s is down.<br />

4 INFORMAT<br />

IONAL<br />

Group %s Port %s is acting as a failover<br />

backup.<br />

Remarks


B.32 TapeAlert-MIB (tapealrt.mib)<br />

<strong>Trap</strong>s from a HP tape device. Refer to the Tape Device manual for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

tapeAlert<strong>Trap</strong>1<br />

HP TapeAlert #1<br />

tapeAlert<strong>Trap</strong>2<br />

HP TapeAlert #2<br />

tapeAlert<strong>Trap</strong>3<br />

HP TapeAlert #3<br />

tapeAlert<strong>Trap</strong>4<br />

HP TapeAlert #4<br />

tapeAlert<strong>Trap</strong>5<br />

HP TapeAlert #5<br />

tapeAlert<strong>Trap</strong>6<br />

HP TapeAlert #6<br />

tapeAlert<strong>Trap</strong>7<br />

HP TapeAlert #7<br />

tapeAlert<strong>Trap</strong>8<br />

HP TapeAlert #8<br />

tapeAlert<strong>Trap</strong>9<br />

HP TapeAlert #9<br />

tapeAlert<strong>Trap</strong>10<br />

HP TapeAlert #10<br />

tapeAlert<strong>Trap</strong>11<br />

HP TapeAlert #11<br />

tapeAlert<strong>Trap</strong>12<br />

HP TapeAlert #12<br />

tapeAlert<strong>Trap</strong>13<br />

HP TapeAlert #13<br />

tapeAlert<strong>Trap</strong>14<br />

HP TapeAlert #14<br />

tapeAlert<strong>Trap</strong>15<br />

HP TapeAlert #15<br />

tapeAlert<strong>Trap</strong>16<br />

HP TapeAlert #16<br />

tapeAlert<strong>Trap</strong>17<br />

HP TapeAlert #17<br />

table: TapeAlert-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.11.2.3.9.7.1)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Problems Reading Data<br />

2 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Problems Writing Data<br />

3 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Read or Write Data<br />

Error<br />

4 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Faulty Media [%s]<br />

5 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device May Have Read Fault - Call<br />

Helpline<br />

6 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device May Have Write Fault - Call<br />

Helpline<br />

7 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Worn Out Media<br />

[%s]<br />

8 MINOR Hba%d:Channel%d:ScsiID%d Media<br />

Loaded In Tape Device Is Not Data<br />

Grade<br />

9 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Attempted Backup to Write-<br />

Protected Tape<br />

10 INFORMAT<br />

IONAL<br />

11 INFORMAT<br />

IONAL<br />

12 INFORMAT<br />

IONAL<br />

Hba%d:Channel%d:ScsiID%d Tape<br />

Device Eject Attempted When Media<br />

Locked<br />

Hba%d:Channel%d:ScsiID%d Tape<br />

Device Attempted Backup/Restore To<br />

Cleaning Tape<br />

Hba%d:Channel%d:ScsiID%d Media<br />

Loaded In Tape Device Is Unsupported<br />

Type<br />

13 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Snapped Tape<br />

14 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Snapped Tape<br />

15 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Memory Chip in Cartridge<br />

Failure [%s]<br />

16 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Cartridge Ejected While Actively<br />

Writing/Reading<br />

17 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Read Only Media<br />

B.32 TapeAlert-MIB (tapealrt.mib)<br />

Remarks<br />

Tape Device monitor<br />

<strong>Trap</strong>.<br />

Not supported.<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

85


86<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

tapeAlert<strong>Trap</strong>18<br />

HP TapeAlert #18<br />

tapeAlert<strong>Trap</strong>19<br />

HP TapeAlert #19<br />

tapeAlert<strong>Trap</strong>20<br />

HP TapeAlert #20<br />

tapeAlert<strong>Trap</strong>21<br />

HP TapeAlert #21<br />

tapeAlert<strong>Trap</strong>22<br />

HP TapeAlert #22<br />

tapeAlert<strong>Trap</strong>23<br />

HP TapeAlert #23<br />

tapeAlert<strong>Trap</strong>29<br />

HP TapeAlert #29<br />

tapeAlert<strong>Trap</strong>30<br />

HP TapeAlert #30<br />

tapeAlert<strong>Trap</strong>31<br />

HP TapeAlert #31<br />

tapeAlert<strong>Trap</strong>32<br />

HP TapeAlert #32<br />

tapeAlert<strong>Trap</strong>33<br />

HP TapeAlert #33<br />

tapeAlert<strong>Trap</strong>34<br />

HP TapeAlert #34<br />

tapeAlert<strong>Trap</strong>35<br />

HP TapeAlert #35<br />

tapeAlert<strong>Trap</strong>36<br />

HP TapeAlert #36<br />

tapeAlert<strong>Trap</strong>37<br />

HP TapeAlert #37<br />

tapeAlert<strong>Trap</strong>38<br />

HP TapeAlert #38<br />

tapeAlert<strong>Trap</strong>39<br />

HP TapeAlert #39<br />

tapeAlert<strong>Trap</strong>40<br />

HP TapeAlert #40<br />

tapeAlert<strong>Trap</strong>41<br />

HP TapeAlert #41<br />

tapeAlert<strong>Trap</strong>42<br />

HP TapeAlert #42<br />

tapeAlert<strong>Trap</strong>43<br />

HP TapeAlert #43<br />

table: TapeAlert-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.11.2.3.9.7.1)<br />

Specific<br />

Level of<br />

importance<br />

18 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Corrupted<br />

Directory On Tape<br />

19 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Worn Out Media<br />

[%s]<br />

20 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Needs Cleaning<br />

21 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Requests Routine Cleaning<br />

22 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Worn Out Cleaning<br />

Cartridge<br />

23 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Detected Invalid Cleaning<br />

Cartridge<br />

29 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Requires Preventative<br />

Maintenance<br />

30 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Hardware Fault - Reset Drive<br />

31 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Hardware Fault - Call<br />

Helpline<br />

32 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Host Interface Fault<br />

33 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Eject Media Request<br />

34 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Firmware Download Fault<br />

35 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Humidity Specification Exceeded<br />

36 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Temperature Specification<br />

Exceeded<br />

37 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Voltage Specification Exceeded<br />

38 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Predicted to Fail - Call Helpline<br />

39 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device May Have Hardware Fault - Run<br />

Diagnostics<br />

40 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Autoloader Communications<br />

Fault<br />

41 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Detects Stray Tape In Autoloader<br />

42 MINOR Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Autoloader Mechanism Fault<br />

43 CRITICAL Hba%d:Channel%d:ScsiID%d Tape<br />

Device Has Autoloader Door Open<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

tapeAlert<strong>Trap</strong>44<br />

HP TapeAlert #44<br />

tapeAlert<strong>Trap</strong>45<br />

HP TapeAlert #45<br />

tapeAlert<strong>Trap</strong>46<br />

HP TapeAlert #46<br />

tapeAlert<strong>Trap</strong>256<br />

HP TapeAlert #256<br />

tapeAlert<strong>Trap</strong>257<br />

HP TapeAlert #257<br />

tapeAlert<strong>Trap</strong>258<br />

HP TapeAlert #258<br />

tapeAlert<strong>Trap</strong>259<br />

HP TapeAlert #259<br />

tapeAlert<strong>Trap</strong>260<br />

HP TapeAlert #260<br />

tapeAlert<strong>Trap</strong>261<br />

HP TapeAlert #261<br />

tapeAlert<strong>Trap</strong>262<br />

HP TapeAlert #262<br />

tapeAlert<strong>Trap</strong>263<br />

HP TapeAlert #263<br />

tapeAlert<strong>Trap</strong>264<br />

HP TapeAlert #264<br />

tapeAlert<strong>Trap</strong>265<br />

HP TapeAlert #265<br />

tapeAlert<strong>Trap</strong>266<br />

HP TapeAlert #266<br />

tapeAlert<strong>Trap</strong>267<br />

HP TapeAlert #267<br />

tapeAlert<strong>Trap</strong>268<br />

HP TapeAlert #268<br />

tapeAlert<strong>Trap</strong>269<br />

HP TapeAlert #269<br />

tapeAlert<strong>Trap</strong>270<br />

HP TapeAlert #270<br />

tapeAlert<strong>Trap</strong>271<br />

HP TapeAlert #271<br />

tapeAlert<strong>Trap</strong>272<br />

HP TapeAlert #272<br />

tapeAlert<strong>Trap</strong>273<br />

HP TapeAlert #273<br />

tapeAlert<strong>Trap</strong>274<br />

HP TapeAlert #274<br />

table: TapeAlert-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.11.2.3.9.7.1)<br />

Specific<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

44 CRITICAL Hba%d:Channel%d:ScsiID%d<br />

Autoloader Has Hardware Fault - Call<br />

Helpline<br />

45 CRITICAL Hba%d:Channel%d:ScsiID%d<br />

Autoloader Cannot Operate Without<br />

Magazine<br />

46 MINOR Hba%d:Channel%d:ScsiID%d<br />

Autoloader Predicted to Fail - Call<br />

Helpline<br />

256 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Has Drive Communications Fault<br />

257 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Has Changer Mechanism Fault<br />

258 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Has Hardware Fault - Reset Library<br />

259 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Has Hardware Fault - Call Helpline<br />

260 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

May Have Hardware Fault - Run<br />

Diagnostics<br />

261 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Has Host Interface Fault<br />

262 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Predicted to Fail - Call Helpline<br />

263 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Requires Preventative Maintenance<br />

264 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Humidity Specification Exceeded<br />

265 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Temperature Specification Exceeded<br />

266 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Voltage Specification Exceeded<br />

267 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Detects Stray Tape In Drive<br />

268 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Has Problems Picking Cartridge from<br />

Slot<br />

269 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Has Problems Placing Cartridge into Slot<br />

270 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Has Problems Loading Cartridge into<br />

Drive<br />

271 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Door is Open<br />

272 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Has Mechanical Fault with Mailslot<br />

273 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Cannot Operate Without Magazine<br />

274 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Security Has Been Compromised<br />

B.32 TapeAlert-MIB (tapealrt.mib)<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks<br />

87


88<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

tapeAlert<strong>Trap</strong>275<br />

HP TapeAlert #275<br />

tapeAlert<strong>Trap</strong>276<br />

HP TapeAlert #276<br />

tapeAlert<strong>Trap</strong>277<br />

HP TapeAlert #277<br />

tapeAlert<strong>Trap</strong>278<br />

HP TapeAlert #278<br />

tapeAlert<strong>Trap</strong>279<br />

HP TapeAlert #279<br />

tapeAlert<strong>Trap</strong>280<br />

HP TapeAlert #280<br />

275 INFORMAT<br />

IONAL<br />

276 INFORMAT<br />

IONAL<br />

277 INFORMAT<br />

IONAL<br />

B.33 IOMMIB (iommib.mib)<br />

<strong>Trap</strong>s from Adaptec IOManager Storage Controllers.<br />

TRAP-TYPE/<br />

Alarm type<br />

iomStorageControllerStateCha<br />

ngeI<br />

Informational Storage<br />

Controller State Change.<br />

iomStorageControllerStateCha<br />

ngeW<br />

Warning Storage Controller<br />

State Change.<br />

iomStorageControllerStateCha<br />

ngeC<br />

Critical Storage Controller<br />

State Change.<br />

iomBusPortStateChangeI<br />

Informational Bus Port State<br />

Change.<br />

iomBusPortStateChangeW<br />

Warning Bus Port State<br />

Change.<br />

iomBusPortStateChangeC<br />

Critical Bus Port State<br />

Change.<br />

iomStorageDeviceStateChang<br />

eI<br />

Informational Storage Device<br />

State Change.<br />

iomStorageDeviceStateChang<br />

eW<br />

Warning Storage Device State<br />

Change.<br />

table: TapeAlert-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.11.2.3.9.7.1)<br />

Specific<br />

Hba%d:Channel%d:ScsiID%d Library<br />

Security Mode Changed<br />

Hba%d:Channel%d:ScsiID%d Library<br />

Manually Turned Offline<br />

Hba%d:Channel%d:ScsiID%d Library<br />

Drive Turned Offline<br />

278 MINOR Hba%d:Channel%d:ScsiID%d Library<br />

Has Problems Reading Barcode Labels<br />

279 CRITICAL Hba%d:Channel%d:ScsiID%d Library<br />

Inventory is Inconsistent<br />

280 MINOR Hba%d:Channel%d:ScsiID%d Invalid<br />

Library Operation Attempted<br />

table: IOMMIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.12.2)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

1010 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The storage controller %d has changed<br />

state.<br />

1011 MAJOR The storage controller %d has changed<br />

state.<br />

1012 CRITICAL The storage controller %d has changed<br />

state.<br />

1020 INFORMAT<br />

IONAL<br />

The bus port %d has changed state.<br />

1021 MAJOR The bus port %d has changed state.<br />

1022 CRITICAL The bus port %d has changed state.<br />

1030 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The storage device %d has changed state.<br />

1031 MAJOR The storage device %d has changed state.<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

↑<br />

Remarks<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

iomStorageDeviceStateChang<br />

eC<br />

Critical Storage Device State<br />

Change.<br />

iomVolumeSetStateChangeI<br />

Informational Volume Set<br />

State Change.<br />

iomVolumeSetStateChangeW<br />

Warning Volume Set State<br />

Change.<br />

iomVolumeSetStateChangeC<br />

Critical Volume Set State<br />

Change.<br />

iomVolumeSetActivityChange<br />

I<br />

Informational Volume Set<br />

Activity Change.<br />

iomVolumeSetActivityChange<br />

W<br />

Warning Volume Set Activity<br />

Change.<br />

iomVolumeSetActivityChange<br />

C<br />

Critical Volume Set Activity<br />

Change.<br />

iomSpareStateChangeI<br />

Informational Spare State<br />

Change.<br />

iomSpareStateChangeW<br />

Warning Spare State Change.<br />

iomSpareStateChangeC<br />

Critical Spare State Change.<br />

iomEnclosureStateChangeI<br />

Informational Enclosure State<br />

Change.<br />

iomEnclosureStateChangeW<br />

Warning Enclosure State<br />

Change.<br />

iomEnclosureStateChangeC<br />

Critical Enclosure State<br />

Change.<br />

table: IOMMIB <strong>Trap</strong> (ENTERPRISE : enterprises.795.12.2)<br />

Specific<br />

Level of<br />

importance<br />

1032 CRITICAL The storage device %d has changed state.<br />

1040 INFORMAT<br />

IONAL<br />

The volume set %d has changed state.<br />

1041 MAJOR The volume set %d has changed state.<br />

1042 CRITICAL The volume set %d has changed state.<br />

1050 INFORMAT<br />

IONAL<br />

The volume set %d has changed activity.<br />

1051 MAJOR The volume set %d has changed activity.<br />

1052 CRITICAL The volume set %d has changed activity.<br />

1060 INFORMAT<br />

IONAL<br />

The spare %d has changed state.<br />

1061 MAJOR The spare %d has changed state.<br />

1062 CRITICAL The spare %d has changed state.<br />

1070 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A component in IOManager enclosure<br />

%d has changed state.<br />

1071 MAJOR A component in IOManager enclosure<br />

%d has changed state.<br />

1072 CRITICAL A component in IOManager enclosure<br />

%d has changed state.<br />

B.33 IOMMIB (iommib.mib)<br />

Remarks<br />

89


90<br />

B <strong>Trap</strong> <strong>List</strong><br />

B.34 BRIDGE-MIB (trap1493.mib)<br />

<strong>Trap</strong>s from BRIDGE device. Refer to the RFC1493 for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

newRoot<br />

a new root of the Spanning<br />

True trap<br />

topologyChange<br />

topology changed trap<br />

B.35 RMON-MIB (trap1757.mib)<br />

<strong>Trap</strong>s from remote network monitor. Refer to the RFC1757 for details.<br />

TRAP-TYPE/<br />

Alarm type<br />

risingAlarm<br />

Rising Alarm <strong>Trap</strong> Sent From<br />

Rmon Manager that the<br />

monitor variables has crosses<br />

its rising threshold<br />

fallingAlarm<br />

Faling Alarm <strong>Trap</strong> Sent From<br />

Rmon Manager that the<br />

monitor variables has crosses<br />

its falling threshold<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

<strong>Trap</strong>s from Wired for Management.<br />

TRAP-TYPE/<br />

Alarm type<br />

wfmTempLowWarningOKWar<br />

n_LNC_GL<br />

Temp Low Warning (OK -><br />

Warn) (LNC_GL)<br />

wfmTempOK_LNC_GH<br />

Temp OK (LNC_GH)<br />

table: BRIDGE-MIB <strong>Trap</strong> (ENTERPRISE : mib2.17)<br />

Specific<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

A trap to inicated when a node has<br />

become a new root of the Spanning True.<br />

A trap to inicated when the topology has<br />

changed.<br />

table: RMON-MIB <strong>Trap</strong> (ENTERPRISE : mib2.16)<br />

Specific<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

The vairable %x we are monitoring has<br />

occured a Rising Alarm, The alarmValue<br />

is %d which has crossed over the<br />

threshold %d within the timeInterval we<br />

defined in Alarm Table. Note: The<br />

infomration of this alarm can be get from<br />

alarm Table index %d and the alarm<br />

SampleType is %d.<br />

The vairable %x we are monitoring has<br />

occured a Falling Alarm, The alarmValue<br />

is %d which has crossed down the<br />

threshold %d within the timeInterval we<br />

defined in Alarm Table. Note: The<br />

infomration of this alarm can be get from<br />

alarm Table index %d and the alarm<br />

SampleType is %d.<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

65792 MAJOR %s<br />

65793 INFORMAT<br />

IONAL<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks<br />

Remarks<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmTempLowCriticalWarnCrit<br />

_LC_GL<br />

Temp Low Critical(Warn -><br />

Crit) (LC_GL)<br />

wfmTempLowWarningCritWar<br />

n_LC_GH<br />

Temp Low Warning (Crit -><br />

Warn) (LC_GH)<br />

wfmTempLowCriticalCritNonR<br />

ecover_LNR_GL<br />

Temp Low Critical(Crit -><br />

NonRecover) (LNR_GL)<br />

wfmTempLowCriticalNonReco<br />

verCrit_LNR_GH<br />

Temp Low<br />

Critical(NonRecover -> Crit)<br />

(LNR_GH)<br />

wfmTempOK_UNC_GL<br />

Temp OK (UNC_GL)<br />

wfmTempHighWarningOKWar<br />

n_UNC_GH<br />

Temp High Warning (OK -><br />

Warn) (UNC_GH)<br />

wfmTempHighWarningCritWar<br />

n_UC_GL<br />

Temp High Warning (Crit -><br />

Warn) (UC_GL)<br />

wfmTempHighCriticalWarnCrit<br />

_UC_GH<br />

Temp High Critical(Warn -><br />

Crit) (UC_GH)<br />

wfmTempHighCriticalNonReco<br />

verCrit_UNR_GL<br />

Temp High<br />

Critical(NonRecover -> Crit)<br />

(UNR_GL)<br />

wfmTempHighCriticalCritNon<br />

Recover_UNR_GH<br />

Temp High Critical(Crit -><br />

NonRecover) (UNR_GH)<br />

wfmTemperatureOk<br />

Temperature Ok<br />

wfmThermalTrip<br />

Thermal trip<br />

wfmTemperatureWarningCritic<br />

al<br />

Temperature High Critical -><br />

Warning<br />

wfmTempOK_LNC_GL<br />

Temp OK (LNC_GL)<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

65794 CRITICAL %s<br />

65795 MAJOR %s<br />

65796 CRITICAL %s<br />

65797 CRITICAL %s<br />

65798 INFORMAT<br />

IONAL<br />

%s<br />

65799 MAJOR %s<br />

65800 MAJOR %s<br />

65801 CRITICAL %s<br />

65802 CRITICAL %s<br />

65803 CRITICAL %s<br />

65927 INFORMAT<br />

IONAL<br />

%s<br />

66049 CRITICAL %s<br />

65929 MINOR %s<br />

98560 INFORMAT<br />

IONAL<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

91


92<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmTempLowWarningOKWar<br />

n_LNC_GH<br />

Temp Low Warning (OK -><br />

Warn) (LNC_GH)<br />

wfmTempLowWarningCritWar<br />

n_LC_GL<br />

Temp Low Warning (Crit -><br />

Warn) (LC_GL)<br />

wfmTempLowCriticalWarnCrit<br />

_LC_GH<br />

Temp Low Critical(Warn -><br />

Crit) (LC_GH)<br />

wfmTempLowCriticalNonReco<br />

verCrit_LNR_GL<br />

Temp Low<br />

Critical(NonRecover -> Crit)<br />

(LNR_GL)<br />

wfmTempLowCriticalCritNonR<br />

ecover_LNR_GH<br />

Temp Low Critical(Crit -><br />

NonRecover) (LNR_GH)<br />

wfmTempHighWarningOKWar<br />

n_UNC_GL<br />

Temp High Warning (OK -><br />

Warn) (UNC_GL)<br />

wfmTempOK_UNC_GH<br />

Temp OK (UNC_GH)<br />

wfmTempHighCriticalWarnCrit<br />

_UC_GL<br />

Temp High Critical(Warn -><br />

Crit) (UC_GL)<br />

wfmTempHighWarningCritWar<br />

n_UC_GH<br />

Temp High Warning (Crit -><br />

Warn) (UC_GH)<br />

wfmTempHighCriticalCritNon<br />

Recover_UNR_GL<br />

Temp High Critical(Crit -><br />

NonRecover) (UNR_GL)<br />

wfmTempHighCriticalNonReco<br />

verCrit_UNR_GH<br />

Temp High<br />

Critical(NonRecover -> Crit)<br />

(UNR_GH)<br />

wfmMemorySingleBitError1<br />

Memory - Single Bit Error 1<br />

wfmVoltageLowWarningOKWa<br />

rn_LNC_GL<br />

Voltage Low - Warning (OK -><br />

Warn) (LNC_GL)<br />

wfmVoltageOK_LNC_GH<br />

Voltage OK (LNC_GH)<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

98561 MAJOR %s<br />

98562 MAJOR %s<br />

98563 CRITICAL %s<br />

98564 CRITICAL %s<br />

98565 CRITICAL %s<br />

98566 MAJOR %s<br />

98567 INFORMAT<br />

IONAL<br />

%s<br />

98568 CRITICAL %s<br />

98569 MAJOR %s<br />

98570 CRITICAL %s<br />

98571 CRITICAL %s<br />

131072 INFORMAT<br />

IONAL<br />

%s<br />

131328 MAJOR %s<br />

131329 INFORMAT<br />

IONAL<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmVoltageLowCriticalWarnCr<br />

it_LC_GL<br />

Voltage Low - Critical(Warn -><br />

Crit) (LC_GL)<br />

wfmVoltageLowNoLongerCriti<br />

cal_LC_GH<br />

Voltage Low - no longer Critical<br />

(LC_GH)<br />

wfmVoltageLowCriticalCritNo<br />

nRecover_LNR_GL<br />

Voltage Low - Critical(Crit -><br />

NonRecover) (LNR_GL)<br />

wfmVoltageLowCriticalNonRe<br />

coverCrit_LNR_GH<br />

Voltage Low -<br />

Critical(NonRecover -> Crit)<br />

(LNR_GH)<br />

wfmVoltageOK_UNC_GL<br />

Voltage OK (UNC_GL)<br />

wfmVoltageHighWarningOKW<br />

arn_UNC_GH<br />

Voltage High - Warning (OK -><br />

Warn) (UNC_GH)<br />

wfmVoltageHighNoLongerCriti<br />

cal_UC_GL<br />

Voltage High - no longer<br />

Critical (UC_GL)<br />

wfmVoltageHighCriticalWarnC<br />

rit_UC_GH<br />

Voltage High - Critical(Warn -><br />

Crit) (UC_GH)<br />

wfmVoltageHighCriticalNonRe<br />

coverCrit_UNR_GL<br />

Voltage High -<br />

Critical(NonRecover -> Crit)<br />

(UNR_GL)<br />

wfmVoltageHighCriticalCritNo<br />

nRecover_UNR_GH<br />

Voltage High - Critical(Crit -><br />

NonRecover) (UNR_GH)<br />

wfmVoltageLimitExceeded<br />

Voltage limit exceeded<br />

wfmMemorySingleBitError2<br />

Memory - Single Bit Error 2<br />

wfmVoltageOK_LNC_GL<br />

Voltage OK (LNC_GL)<br />

wfmMemorySingleBitError3<br />

Memory - Single Bit Error 3<br />

wfmVoltageLowWarningOKWa<br />

rn_LNC_GH<br />

Voltage Low - Warning (OK -><br />

Warn) (LNC_GH)<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

131330 CRITICAL %s<br />

131331 INFORMAT<br />

IONAL<br />

%s<br />

131332 CRITICAL %s<br />

131333 CRITICAL %s<br />

131334 INFORMAT<br />

IONAL<br />

%s<br />

131335 MAJOR %s<br />

131336 INFORMAT<br />

IONAL<br />

%s<br />

131337 CRITICAL %s<br />

131338 CRITICAL %s<br />

131339 CRITICAL %s<br />

132353 CRITICAL %s<br />

133632 INFORMAT<br />

IONAL<br />

164096 INFORMAT<br />

IONAL<br />

134784 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

164097 MAJOR %s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

93


94<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmMemorySingleBitError4<br />

Memory - Single Bit Error 4<br />

wfmVoltageLowNoLongerCriti<br />

cal_LC_GL<br />

Voltage Low - no longer Critical<br />

(LC_GL)<br />

wfmMemorySingleBitError5<br />

Memory - Single Bit Error 5<br />

wfmVoltageLowCriticalWarnCr<br />

it_LC_GH<br />

Voltage Low - Critical(Warn -><br />

Crit) (LC_GH)<br />

wfmMemorySingleBitError6<br />

Memory - Single Bit Error 6<br />

wfmVoltageLowCriticalNonRe<br />

coverCrit_LNR_GL<br />

Voltage Low -<br />

Critical(NonRecover -> Crit)<br />

(LNR_GL)<br />

wfmMemorySingleBitError7<br />

Memory - Single Bit Error 7<br />

wfmVoltageLowCriticalCritNo<br />

nRecover_LNR_GH<br />

Voltage Low - Critical(Crit -><br />

NonRecover) (LNR_GH)<br />

wfmMemorySingleBitError8<br />

Memory - Single Bit Error 8<br />

wfmVoltageHighWarningOKW<br />

arn_UNC_GL<br />

Voltage High - Warning (OK -><br />

Warn) (UNC_GL)<br />

wfmMemorySingleBitError9<br />

Memory - Single Bit Error 9<br />

wfmVoltageOK_UNC_GH<br />

Voltage OK (UNC_GH)<br />

wfmMemorySingleBitError10<br />

Memory - Single Bit Error 10<br />

wfmVoltageHighCriticalWarnC<br />

rit_UC_GL<br />

Voltage High - Critical(Warn -><br />

Crit) (UC_GL)<br />

wfmMemorySingleBitError11<br />

Memory - Single Bit Error 11<br />

wfmVoltageHighNoLongerCriti<br />

cal_UC_GH<br />

Voltage High - no longer<br />

Critical (UC_GH)<br />

wfmMemorySingleBitError12<br />

Memory - Single Bit Error 12<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

135168 INFORMAT<br />

IONAL<br />

164098 INFORMAT<br />

IONAL<br />

135552 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

164099 CRITICAL %s<br />

137088 INFORMAT<br />

IONAL<br />

%s<br />

164100 CRITICAL %s<br />

137344 INFORMAT<br />

IONAL<br />

%s<br />

164101 CRITICAL %s<br />

137984 INFORMAT<br />

IONAL<br />

%s<br />

164102 MAJOR %s<br />

139392 INFORMAT<br />

IONAL<br />

164103 INFORMAT<br />

IONAL<br />

139393 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

164104 CRITICAL %s<br />

143232 INFORMAT<br />

IONAL<br />

164105 INFORMAT<br />

IONAL<br />

144384 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmVoltageHighCriticalCritNo<br />

nRecover_UNR_GL<br />

Voltage High - Critical(Crit -><br />

NonRecover) (UNR_GL)<br />

wfmMemorySingleBitError13<br />

Memory - Single Bit Error 13<br />

wfmVoltageHighCriticalNonRe<br />

coverCrit_UNR_GH<br />

Voltage High -<br />

Critical(NonRecover -> Crit)<br />

(UNR_GH)<br />

wfmMemorySingleBitError14<br />

Memory - Single Bit Error 14<br />

wfmFanPreFailOKWarn_LNC_<br />

GL<br />

Fan Pre-Fail (OK -> Warn)<br />

(LNC_GL)<br />

wfmMemorySingleBitError15<br />

Memory - Single Bit Error 15<br />

wfmFanIsWorkingOK_LNC_GH<br />

Fan is working (OK)<br />

(LNC_GH)<br />

wfmMemorySingleBitError16<br />

Memory - Single Bit Error 16<br />

wfmFanFailedWarnCrit_LC_GL<br />

Fan Failed (Warn -> Crit)<br />

(LC_GL)<br />

wfmMemorySingleBitError17<br />

Memory - Single Bit Error 17<br />

wfmFanPreFailCritWarn_LC_<br />

GH<br />

Fan Pre-Fail(Crit -> Warn)<br />

(LC_GH)<br />

wfmMemorySingleBitError18<br />

Memory - Single Bit Error 18<br />

wfmFanFailedCritNonRecover<br />

_LNR_GL<br />

Fan Failed (Crit -><br />

NonRecover) (LNR_GL)<br />

wfmMemorySingleBitError19<br />

Memory - Single Bit Error 19<br />

wfmFanFailedNonRecoverCrit<br />

_LNR_GH<br />

Fan Failed (NonRecover -><br />

Crit) (LNR_GH)<br />

wfmMemorySingleBitError20<br />

Memory - Single Bit Error 20<br />

wfmFanOK<br />

Fan OK<br />

wfmMemorySingleBitError21<br />

Memory - Single Bit Error 21<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

164106 CRITICAL %s<br />

148352 INFORMAT<br />

IONAL<br />

%s<br />

164107 CRITICAL %s<br />

153088 INFORMAT<br />

IONAL<br />

%s<br />

262400 MAJOR %s<br />

153472 INFORMAT<br />

IONAL<br />

262401 INFORMAT<br />

IONAL<br />

153984 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

262402 CRITICAL %s<br />

154496 INFORMAT<br />

IONAL<br />

%s<br />

262403 MAJOR %s<br />

154624 INFORMAT<br />

IONAL<br />

%s<br />

262404 CRITICAL %s<br />

154752 INFORMAT<br />

IONAL<br />

%s<br />

262405 CRITICAL %s<br />

155392 INFORMAT<br />

IONAL<br />

262912 INFORMAT<br />

IONAL<br />

155904 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

95


96<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmFanFailed<br />

Fan Failed<br />

wfmMemorySingleBitError22<br />

Memory - Single Bit Error 22<br />

wfmFanPredictiveFailureDeass<br />

erted<br />

Fan predictive failure<br />

deasserted<br />

wfmMemorySingleBitError23<br />

Memory - Single Bit Error 23<br />

wfmFanPredictiveFailureAssert<br />

ed<br />

Fan predictive failure asserted<br />

wfmMemorySingleBitError24<br />

Memory - Single Bit Error 24<br />

wfmFanRemoved<br />

Fan removed<br />

wfmMemorySingleBitError25<br />

Memory - Single Bit Error 25<br />

wfmFanRestoredreplaced<br />

Fan restored/replaced<br />

wfmMemorySingleBitError26<br />

Memory - Single Bit Error 26<br />

wfmFANSensorSpecificErrorR<br />

eported<br />

FAN Sensor specific Error<br />

reported<br />

wfmMemorySingleBitError27<br />

Memory - Single Bit Error 27<br />

wfmFanIsWorkingOK_LNC_GL<br />

Fan is working (OK)<br />

(LNC_GL)<br />

wfmMemorySingleBitError28<br />

Memory - Single Bit Error 28<br />

wfmFanPreFailOKWarn_LNC_<br />

GH<br />

Fan Pre-Fail(OK -> Warn)<br />

(LNC_GH)<br />

wfmMemorySingleBitError29<br />

Memory - Single Bit Error 29<br />

wfmFanPreFailCritWarn_LC_<br />

GL<br />

Fan Pre-Fail(Crit -> Warn)<br />

(LC_GL)<br />

wfmFanFailedWarnCrit_LC_GH<br />

Fan Failed (Warn -> Crit)<br />

(LC_GH)<br />

wfmFanFailedNonRecoverCrit<br />

_LNR_GL<br />

Fan Failed (NonRecover -><br />

Crit) (LNR_GL)<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

262913 CRITICAL %s<br />

156416 INFORMAT<br />

IONAL<br />

%s<br />

263168 MAJOR %s<br />

157184 INFORMAT<br />

IONAL<br />

%s<br />

263169 MAJOR %s<br />

157696 INFORMAT<br />

IONAL<br />

264192 INFORMAT<br />

IONAL<br />

158208 INFORMAT<br />

IONAL<br />

264193 INFORMAT<br />

IONAL<br />

158464 INFORMAT<br />

IONAL<br />

290560 INFORMAT<br />

IONAL<br />

159104 INFORMAT<br />

IONAL<br />

295168 INFORMAT<br />

IONAL<br />

159872 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

295169 MAJOR %s<br />

162304 INFORMAT<br />

IONAL<br />

%s<br />

295170 MAJOR %s<br />

295171 CRITICAL %s<br />

295172 CRITICAL %s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmFanFailedCritNonRecover<br />

_LNR_GH<br />

Fan Failed (Crit -><br />

NonRecover) (LNR_GH)<br />

wfmPhysicalIntrusionclosed<br />

Physical intrusion (closed)<br />

wfmPhysicalIntrusionopened<br />

Physical intrusion (opened)<br />

wfmChassisIntrusionopened<br />

Chassis Intrusion (opened)<br />

wfmDriveBayIntrusionopened<br />

DriveBay Intrusion (opened)<br />

wfmIOAreaIntrusionopened<br />

I/O area Intrusion (opened)<br />

wfmCPUAreaIntrusionopened<br />

CPU area Intrusion (opened)<br />

wfmLANLeashLostCableUnplu<br />

gged<br />

LAN Leash lost (Cable<br />

unplugged)<br />

wfmUnautorizedDockundock<br />

Unautorized dock/undock<br />

wfmFANAreaIntrusionopened<br />

FAN Area Intrusion (opened)<br />

wfmChassisIntrusion<br />

Chassis Intrusion<br />

wfmChassisIntrusionclosed<br />

Chassis Intrusion (closed)<br />

wfmDriveBayIntrusionclosed<br />

DriveBay Intrusion (closed)<br />

wfmIOAreaIntrusionclosed<br />

I/O area Intrusion (closed)<br />

wfmCPUAreaIntrusionclosed<br />

CPU area Intrusion (closed)<br />

wfmLANLeashReconnected<br />

LAN Leash reconnected<br />

wfmUnautorizedDockundock<br />

Unautorized dock/undock<br />

wfmFANAreaIntrusionclosed<br />

FAN Area Intrusion (closed)<br />

wfmSecureModeViolationAtte<br />

mptFrontPanelButtonReleased<br />

Secure mode violation attempt:<br />

front panel button released<br />

wfmSecureModeViolationAtte<br />

mptFrontPanelButtonPressed<br />

Secure mode violation attempt:<br />

front panel button pressed<br />

wfmSecureModeViolationAtte<br />

mptFrontPanelButtonPressed<br />

Secure mode violation attempt:<br />

front panel button pressed<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

295173 CRITICAL %s<br />

328448 INFORMAT<br />

IONAL<br />

%s<br />

328449 MINOR %s<br />

356096 MINOR %s<br />

356097 MINOR %s<br />

356098 MAJOR %s<br />

356099 MAJOR %s<br />

356100 MAJOR %s<br />

356101 MAJOR %s<br />

356102 MINOR %s<br />

356224 INFORMAT<br />

IONAL<br />

388864 INFORMAT<br />

IONAL<br />

388865 INFORMAT<br />

IONAL<br />

388866 INFORMAT<br />

IONAL<br />

388867 INFORMAT<br />

IONAL<br />

388868 INFORMAT<br />

IONAL<br />

388869 INFORMAT<br />

IONAL<br />

388870 INFORMAT<br />

IONAL<br />

393984 INFORMAT<br />

IONAL<br />

393985 INFORMAT<br />

IONAL<br />

421632 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

97


98<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmSecureModeViolationAtte<br />

mptPrebootUSERPasswordWro<br />

ng<br />

Secure mode violation attempt:<br />

Pre-boot USER password<br />

wrong<br />

wfmSecureModeViolationAtte<br />

mptPrebootSETUPPasswordWr<br />

ong<br />

Secure mode violation attempt:<br />

Pre-boot SETUP password<br />

wrong<br />

wfmSecureModeViolationAtte<br />

mptPrebootNETWORKPasswo<br />

rdWrong<br />

Secure mode violation attempt:<br />

Pre-boot NETWORK password<br />

wrong<br />

wfmSecureModeViolationAtte<br />

mptPrebootOTHERPasswordW<br />

rong<br />

Secure mode violation attempt:<br />

Pre-boot OTHER password<br />

wrong<br />

wfmSecureModeViolationAtte<br />

mptOutofbandAccessPassword<br />

Wrong<br />

Secure mode violation attempt:<br />

Out-of-band access password<br />

wrong<br />

wfmCPUPredictiveFailure<br />

CPU Predictive Failure<br />

wfmCPUInternalError<br />

CPU internal error<br />

wfmCPUThermalTripFailure<br />

CPU thermal trip failure<br />

wfmCPUFailedBuiltinSelftestD<br />

isabledFRB1<br />

CPU failed built-in selftest;<br />

disabled (FRB1)<br />

wfmCPUHungDuringPOSTDis<br />

abledFRB2<br />

CPU hung during POST;<br />

disabled (FRB2)<br />

wfmCPUStartupinitializationFa<br />

ilureDisabledFRB3<br />

CPU startup/initialization<br />

failure; disabled (FRB3)<br />

wfmCPUConfigurationError<br />

CPU configuration error<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

421633 INFORMAT<br />

IONAL<br />

421634 INFORMAT<br />

IONAL<br />

421635 INFORMAT<br />

IONAL<br />

421636 INFORMAT<br />

IONAL<br />

421637 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

459777 MAJOR %s<br />

487168 CRITICAL %s<br />

487169 CRITICAL %s<br />

487170 CRITICAL %s<br />

487171 CRITICAL %s<br />

487172 CRITICAL %s<br />

487173 MAJOR %s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmUncorrectableCPUcomplex<br />

Error<br />

Uncorrectable CPU-complex<br />

error<br />

wfmCPUPresenceDetected<br />

CPU presence detected<br />

wfmCPUDisabled<br />

CPU Disabled<br />

wfmCPUTerminatorPresenceD<br />

etected<br />

CPU terminator presence<br />

detected<br />

wfmCPUThrottledstart<br />

CPU throttled (start)<br />

wfmCpuClockUnthrottle<br />

CPU clock unthrottle<br />

wfmCPUFailedBISTDisabledF<br />

RB1<br />

CPU failed BIST; disabled<br />

(FRB1)<br />

wfmCPUDisabled<br />

CPU Disabled<br />

wfmCPUNotPresent<br />

CPU not present<br />

wfmCPUTerminatorNotDetected<br />

CPU terminator not detected<br />

wfmCPUThrottleEnd<br />

CPU throttle end<br />

wfmCPUEnabled<br />

CPU Enabled<br />

wfmPowerSupplyInserted<br />

Power supply inserted<br />

wfmPowerSupplyAuxDCPower<br />

Fail<br />

Power supply Aux/DC power<br />

fail<br />

wfmPowerSupplyPredictiveFail<br />

ure<br />

Power supply predictive failure<br />

wfmPowerSupplyInputLostAC<br />

DC<br />

Power supply input lost (AC/<br />

DC)<br />

wfmPowerSupplyInputLostOrO<br />

utofrange<br />

Power supply input lost or outof-range<br />

wfmPowerSupplyInputOutofra<br />

ngeButPresent<br />

Power supply input out-ofrange,<br />

but present<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

487174 CRITICAL %s<br />

487175 INFORMAT<br />

IONAL<br />

487176 INFORMAT<br />

IONAL<br />

487177 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

487178 MAJOR %s<br />

487306 INFORMAT<br />

IONAL<br />

%s<br />

487330 CRITICAL %s<br />

487336 INFORMAT<br />

IONAL<br />

519943 INFORMAT<br />

IONAL<br />

519945 INFORMAT<br />

IONAL<br />

519946 INFORMAT<br />

IONAL<br />

520104 INFORMAT<br />

IONAL<br />

552704 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

552705 CRITICAL %s<br />

552706 CRITICAL %s<br />

552707 CRITICAL %s<br />

552708 CRITICAL %s<br />

552709 CRITICAL %s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

99


100<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmPowerSupplyConfiguration<br />

Error<br />

Power supply configuration<br />

error<br />

wfmPowerSupplyRemoved<br />

Power supply removed<br />

wfmPowerUnitCriticalNumber<br />

OfPS<br />

Power unit critical number of<br />

PS<br />

wfmPowerUnitRedundancyReg<br />

ained<br />

Power unit redundancy regained<br />

wfmPowerUnitRedundancyLost<br />

Power unit redundancy lost<br />

wfmPowerUnitPowerOffPower<br />

Down<br />

Power Unit - Power Off / Power<br />

Down<br />

wfmPowerUnitPowerCycle<br />

Power Unit - Power cycle<br />

wfmPowerUnit240VAPowerDo<br />

wn<br />

Power Unit - 240 VA Power<br />

Down<br />

wfmInterlockPowerDown<br />

Interlock Power down<br />

wfmPowerUnitACLost<br />

Power unit - A/C lost<br />

wfmPowerUnitSoftPowerContr<br />

olFailure<br />

Power unit - Soft Power Control<br />

failure<br />

wfmPowerUnitFailure<br />

Power unit failure<br />

wfmPowerUnitPredictiveFailure<br />

Power unit predictive failure<br />

wfmPowerUnitPowerOn<br />

Power Unit - Power On<br />

wfmPowerUnit240VAPowerRe<br />

stored<br />

Power Unit - 240 VA Power<br />

restored<br />

wfmInterlockPowerRestored<br />

Interlock Power restored<br />

wfmPowerUnitPowerRestored<br />

Power unit - Power restored<br />

wfmPowerUnitOK<br />

Power unit OK<br />

wfmMultipleFanFailure<br />

Multiple fan failure<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

552710 MAJOR %s<br />

585472 INFORMAT<br />

IONAL<br />

592390 INFORMAT<br />

IONAL<br />

592640 INFORMAT<br />

IONAL<br />

592641 INFORMAT<br />

IONAL<br />

618240 INFORMAT<br />

IONAL<br />

618241 INFORMAT<br />

IONAL<br />

618242 INFORMAT<br />

IONAL<br />

618243 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

618244 CRITICAL %s<br />

618245 MAJOR %s<br />

618246 MAJOR %s<br />

618247 MAJOR %s<br />

651008 INFORMAT<br />

IONAL<br />

651010 INFORMAT<br />

IONAL<br />

651011 INFORMAT<br />

IONAL<br />

651012 INFORMAT<br />

IONAL<br />

651014 INFORMAT<br />

IONAL<br />

683776 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmMemoryPDAEventModule<br />

Memory - PDA event Module<br />

wfmMemorySinglebitError<br />

Memory - Single-bit error<br />

wfmMemoryMultibitError<br />

Memory - Multi-bit error<br />

wfmMemoryParityError<br />

Memory - Parity error<br />

wfmMemoryScrubFailed<br />

Memory - scrub failed<br />

wfmMemoryDeviceDisabled<br />

Memory - device disabled<br />

wfmMemoryErrorLoggingLimi<br />

tReached<br />

Memory - error logging limit<br />

reached<br />

wfmMemoryPresenceDetected<br />

Memory - presence detected<br />

wfmMemoryConfigurationError<br />

Memory - configuration error<br />

wfmMemorySpare<br />

Memory - spare<br />

wfmMemoryDeviceDisabled<br />

Memory - device disabled<br />

wfmMemoryDeviceRemoved<br />

Memory - device removed<br />

wfmMemoryDeviceEnabled<br />

Memory - device enabled<br />

wfmHotswapCageRemoved<br />

Hotswap cage removed<br />

wfmHotswapCageInserted<br />

Hotswap cage inserted<br />

wfmPOSTMemoryResizedConf<br />

igChanged<br />

POST - Memory Resized/<br />

Config changed<br />

wfmPOSTGenericError<br />

POST - Generic error<br />

wfmPOSTError<br />

POST - Error<br />

wfmPOSTSystemFirmwareHA<br />

NG<br />

POST - System Firmware<br />

HANG<br />

wfmPOSTSystemFirmwarePR<br />

OGRESS<br />

POST - System Firmware<br />

PROGRESS<br />

wfmCorrectableMemoryErrorL<br />

oggingDisabled<br />

Correctable memory error<br />

logging disabled<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

787617 INFORMAT<br />

IONAL<br />

%s<br />

814848 MINOR %s<br />

814849 CRITICAL %s<br />

814850 CRITICAL %s<br />

814851 INFORMAT<br />

IONAL<br />

814852 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

814853 MAJOR %s<br />

814854 INFORMAT<br />

IONAL<br />

%s<br />

814855 MAJOR %s<br />

814856 INFORMAT<br />

IONAL<br />

815012 INFORMAT<br />

IONAL<br />

847622 INFORMAT<br />

IONAL<br />

847780 INFORMAT<br />

IONAL<br />

854016 INFORMAT<br />

IONAL<br />

854017 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

945920 MAJOR %s<br />

983040 INFORMAT<br />

IONAL<br />

%s<br />

1011456 CRITICAL %s<br />

1011457 CRITICAL %s<br />

1011458 INFORMAT<br />

IONAL<br />

1076992 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

101


102<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmLoggingDisabledForErrorT<br />

ype<br />

Logging disabled for error type<br />

wfmEventLogCleared<br />

Event log cleared<br />

wfmAllEventLoggingDisabled<br />

All Event logging disabled<br />

wfmSELFull<br />

SEL full<br />

wfmSELAlmostFull<br />

SEL almost full<br />

wfmCorrectableMemoryErrorL<br />

ogging<br />

Correctable memory error<br />

logging<br />

wfmCorrectableMemoryErrorL<br />

oggingEnabled<br />

Correctable memory error<br />

logging enabled<br />

wfmLoggingEnabledForErrorT<br />

ype<br />

Logging enabled for error type<br />

wfmAllEventLoggingEnabled<br />

All Event logging enabled<br />

wfmWatchdogBIOSWatchdogR<br />

eset<br />

Watchdog: BIOS Watchdog<br />

Reset<br />

wfmWatchdogOSWatchdogRes<br />

et<br />

Watchdog: OS Watchdog Reset<br />

wfmWatchdogOSWatchdogShu<br />

tdown<br />

Watchdog: OS Watchdog<br />

Shutdown<br />

wfmWatchdogOSWatchdogPo<br />

werDown<br />

Watchdog: OS Watchdog Power<br />

Down<br />

wfmWatchdogOSWatchdogPo<br />

werCycle<br />

Watchdog: OS Watchdog Power<br />

Cycle<br />

wfmWatchdogOSWatchdogNM<br />

IDiagnosticInt<br />

Watchdog: OS Watchdog NMI/<br />

Diagnostic Int.<br />

wfmWatchdogOSWatchdogStat<br />

usExpired<br />

Watchdog: OS Watchdog Status<br />

Expired<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1076993 INFORMAT<br />

IONAL<br />

1076994 INFORMAT<br />

IONAL<br />

1076995 INFORMAT<br />

IONAL<br />

1076996 INFORMAT<br />

IONAL<br />

1076997 INFORMAT<br />

IONAL<br />

1077120 INFORMAT<br />

IONAL<br />

1109760 INFORMAT<br />

IONAL<br />

1109761 INFORMAT<br />

IONAL<br />

1109763 INFORMAT<br />

IONAL<br />

1142528 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

1142529 CRITICAL %s<br />

1142530 CRITICAL %s<br />

1142531 CRITICAL %s<br />

1142532 CRITICAL %s<br />

1142533 CRITICAL %s<br />

1142534 CRITICAL %s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmWatchdogOSWatchdogPret<br />

imeoutInterruptNonNMI<br />

Watchdog: OS Watchdog pretimeout<br />

Interrupt, non-NMI<br />

wfmUnspecifiedSystemEvent<br />

Unspecified system event<br />

wfmSystemReconfigured<br />

System reconfigured<br />

wfmSystemBootPOSTComplete<br />

System boot (POST complete)<br />

wfmUndeterminedSystemHard<br />

wareFailure<br />

Undetermined system hardware<br />

failure<br />

wfmEntryAddedToAuxiliaryLog<br />

Entry added to Auxiliary Log<br />

wfmEmergencyPowerOff<br />

Emergency PowerOff<br />

wfmTimestampClockSynchEve<br />

nt<br />

Timestamp Clock Synch event<br />

wfmSystemReconfigurationEve<br />

ntDetected<br />

System reconfiguration event<br />

detected<br />

wfmFrontPanelNMIDiagnosticI<br />

nterrupt<br />

Front Panel NMI / Diagnostic<br />

Interrupt<br />

wfmBusTimeout<br />

Bus timeout<br />

wfmIOChannelCheckNMI<br />

I/O channel check NMI<br />

wfmSoftwareNMI<br />

Software NMI<br />

wfmPCIPERR<br />

PCI PERR<br />

wfmPCISERR<br />

PCI SERR<br />

wfmEISAFailsafeTimerExpired<br />

EISA Failsafe timer expired<br />

wfmCorrectableBusError<br />

Correctable bus error<br />

wfmUncorrectableBusError<br />

Uncorrectable bus error<br />

wfmFatalNMIPort61hBit7<br />

Fatal NMI (Port 61h Bit 7)<br />

wfmPOWERButtonPressed<br />

POWER Button pressed<br />

wfmSLEEPButtonPressed<br />

SLEEP Button pressed<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1142535 INFORMAT<br />

IONAL<br />

1206016 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

1208064 MINOR %s<br />

1208065 INFORMAT<br />

IONAL<br />

%s<br />

1208066 CRITICAL %s<br />

1208067 INFORMAT<br />

IONAL<br />

1208068 INFORMAT<br />

IONAL<br />

1208069 INFORMAT<br />

IONAL<br />

1208070 INFORMAT<br />

IONAL<br />

%s<br />

Emergency PowerOff, if Server failed to<br />

boot Diagnostic System. Details: %s<br />

%s<br />

%s<br />

1273600 CRITICAL %s<br />

1273601 CRITICAL %s<br />

1273602 CRITICAL %s<br />

1273603 CRITICAL %s<br />

1273604 CRITICAL %s<br />

1273605 CRITICAL %s<br />

1273606 CRITICAL %s<br />

1273607 CRITICAL %s<br />

1273608 CRITICAL %s<br />

1273609 CRITICAL %s<br />

1339136 INFORMAT<br />

IONAL<br />

1339137 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

103


104<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmRESETButtonPressed<br />

RESET Button pressed<br />

wfmFRULatchOpen<br />

FRU - latch open<br />

wfmFRUServiceRequested<br />

FRU - service requested<br />

wfmSCSIDuplexBoardHasBee<br />

nRemoved<br />

SCSI Duplex Board has been<br />

removed<br />

wfmSCSIDuplexBoardHasBee<br />

nInserted<br />

SCSI Duplex Board has been<br />

inserted<br />

wfmCacheProtocolAndParityEr<br />

ror<br />

Cache protocol and parity error<br />

wfmSoftPowerControlFailed<br />

Soft Power Control Failed<br />

wfmACPIHardwareFailure<br />

ACPI hardware failure<br />

wfmCableConnected<br />

Cable connected<br />

wfmCableDisconnected<br />

Cable disconnected<br />

wfmTerminatorAttached<br />

Terminator attached<br />

wfmTerminatorRemoved<br />

Terminator removed<br />

wfmSystemRebootedByPower<br />

Up<br />

System rebooted by PowerUp<br />

wfmSystemRebootedByHardRe<br />

set<br />

System rebooted by Hard Reset<br />

wfmSystemRebootedByWarmR<br />

eset<br />

System rebooted by Warm<br />

Reset<br />

wfmSystemRebootedToPXEBo<br />

ot<br />

System rebooted to PXE Boot<br />

wfmDiagnosticSystemBoot<br />

Diagnostic System boot<br />

wfmNoBootableMedia<br />

No bootable media<br />

wfmNonBootableDisketteLeftI<br />

nDrive<br />

Non bootable diskette left in<br />

drive<br />

wfmPXEServerNotFound<br />

PXE Server not found<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1339138 INFORMAT<br />

IONAL<br />

1339139 INFORMAT<br />

IONAL<br />

1339140 INFORMAT<br />

IONAL<br />

1378400 INFORMAT<br />

IONAL<br />

1378401 INFORMAT<br />

IONAL<br />

1640354 INFORMAT<br />

IONAL<br />

1666816 INFORMAT<br />

IONAL<br />

1667136 INFORMAT<br />

IONAL<br />

1771520 INFORMAT<br />

IONAL<br />

1771521 INFORMAT<br />

IONAL<br />

1837056 INFORMAT<br />

IONAL<br />

1837057 INFORMAT<br />

IONAL<br />

1928960 INFORMAT<br />

IONAL<br />

1928961 INFORMAT<br />

IONAL<br />

1928962 INFORMAT<br />

IONAL<br />

1928963 INFORMAT<br />

IONAL<br />

1928964 INFORMAT<br />

IONAL<br />

1994496 INFORMAT<br />

IONAL<br />

1994497 INFORMAT<br />

IONAL<br />

1994498 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Server boots to Diagnostic System.<br />

Details: %s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmInvalidBootSector<br />

Invalid boot sector<br />

wfmTimeoutWaitingForUserSel<br />

ectionOfBootSource<br />

Timeout waiting for user<br />

selection of boot source<br />

wfmABootCompleted<br />

A: Boot completed<br />

wfmCBootCompleted<br />

C: Boot completed<br />

wfmPXEBootCompleted<br />

PXE Boot completed<br />

wfmDiagnosticBootCompleted<br />

Diagnostic Boot completed<br />

wfmCDROMBootCompleted<br />

CD-ROM Boot completed<br />

wfmROMBootCompleted<br />

ROM Boot completed<br />

wfmBootCompletedBootDevic<br />

eNotSpecified<br />

Boot completed - boot device<br />

not specified<br />

wfmStopDuringOSLoadInitiali<br />

zation<br />

Stop during OS load /<br />

initialization<br />

wfmRuntimeStop<br />

Run-time Stop<br />

wfmPCIHotPlugSlotFaultAsser<br />

ted<br />

PCI Hot Plug Slot fault asserted<br />

wfmPCIHotPlugSlotIdentifyAs<br />

serted<br />

PCI Hot Plug Slot identify<br />

asserted<br />

wfmPCIHotPlugSlotDeviceInst<br />

alled<br />

PCI Hot Plug Slot Device<br />

installed<br />

wfmPCIHotPlugSlotReadyFor<br />

DeviceInstallation<br />

PCI Hot Plug Slot ready for<br />

device installation<br />

wfmPCIHotPlugSlotReadyFor<br />

DeviceRemoval<br />

PCI Hot Plug Slot ready for<br />

device removal<br />

wfmPCIHotPlugSlotPoweredOff<br />

PCI Hot Plug Slot powered off<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

1994499 INFORMAT<br />

IONAL<br />

1994500 INFORMAT<br />

IONAL<br />

2060032 INFORMAT<br />

IONAL<br />

2060033 INFORMAT<br />

IONAL<br />

2060034 INFORMAT<br />

IONAL<br />

2060035 INFORMAT<br />

IONAL<br />

2060036 INFORMAT<br />

IONAL<br />

2060037 INFORMAT<br />

IONAL<br />

2060038 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

2125568 MAJOR %s<br />

2125569 MAJOR %s<br />

2191104 MAJOR %s<br />

2191105 INFORMAT<br />

IONAL<br />

2191106 INFORMAT<br />

IONAL<br />

2191107 INFORMAT<br />

IONAL<br />

2191108 INFORMAT<br />

IONAL<br />

2191109 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

105


106<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmPCIHotPlugSlotRemovalR<br />

equest<br />

PCI Hot Plug Slot removal<br />

request<br />

wfmPCIHotPlugSlotInterlockA<br />

ssertedlatchNotClosed PCI Hot<br />

Plug Slot Interlock asserted<br />

(latch not closed)<br />

wfmPCIHotPlugSlotDisabled<br />

PCI Hot Plug Slot disabled<br />

wfmPCIHotPlugSlotHoldsSpar<br />

eDevice<br />

PCI Hot Plug Slot holds spare<br />

device<br />

wfmPCIHotPlugSlotFaultDeass<br />

erted<br />

PCI Hot Plug Slot fault<br />

deasserted<br />

wfmPCIHotPlugSlotIdentifyDe<br />

asserted<br />

PCI Hot Plug Slot identify<br />

deasserted<br />

wfmPCIHotPlugSlotDeviceRe<br />

moved<br />

PCI Hot Plug Slot Device<br />

removed<br />

wfmPCIHotPlugSlotPoweredOn<br />

PCI Hot Plug Slot powered on<br />

wfmPCIHotPlugSlotEnabled<br />

PCI Hot Plug Slot enabled<br />

wfmACPIPowerStateWorkingS<br />

0G0<br />

ACPI Power State: working<br />

(S0/G0)<br />

wfmACPIPowerStateSleepingS1<br />

ACPI Power State: sleeping<br />

(S1)<br />

wfmACPIPowerStateSleepingS2<br />

ACPI Power State: sleeping<br />

(S2)<br />

wfmACPIPowerStateSleepingS3<br />

ACPI Power State: sleeping<br />

(S3)<br />

wfmACPIPowerStateSleepingS<br />

4SuspendToDisk<br />

ACPI Power State: sleeping (S4<br />

- Suspend to disk)<br />

wfmACPIPowerStateSleepingS<br />

5SoftOff<br />

ACPI Power State: sleeping (S5<br />

- soft off)<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

2191110 INFORMAT<br />

IONAL<br />

2191111 INFORMAT<br />

IONAL<br />

2191112 INFORMAT<br />

IONAL<br />

2191113 INFORMAT<br />

IONAL<br />

2223872 INFORMAT<br />

IONAL<br />

2223873 INFORMAT<br />

IONAL<br />

2223874 INFORMAT<br />

IONAL<br />

2223877 INFORMAT<br />

IONAL<br />

2223880 INFORMAT<br />

IONAL<br />

2256640 INFORMAT<br />

IONAL<br />

2256641 INFORMAT<br />

IONAL<br />

2256642 INFORMAT<br />

IONAL<br />

2256643 INFORMAT<br />

IONAL<br />

2256644 INFORMAT<br />

IONAL<br />

2256645 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmACPIPowerStateSleepingS<br />

4S5<br />

ACPI Power State: sleeping<br />

(S4/S5)<br />

wfmACPIPowerStateSleepingG<br />

7MechanicalOff<br />

ACPI Power State: sleeping (G7<br />

- mechanical off)<br />

wfmACPIPowerStateSleepingS<br />

1S2S3<br />

ACPI Power State: sleeping<br />

(S1/S2/S3)<br />

wfmACPIPowerStateSleepingG1<br />

ACPI Power State: sleeping<br />

(G1)<br />

wfmACPIPowerStateSleepingS<br />

5ByOverrride<br />

ACPI Power State: sleeping (S5<br />

- by overrride)<br />

wfmACPIPowerStateLegacyO<br />

NState<br />

ACPI Power State: Legacy ON<br />

State<br />

wfmACPIPowerStateLegacyOF<br />

FState<br />

ACPI Power State: Legacy OFF<br />

State<br />

wfmACPIPowerStateUnknown<br />

ACPI Power State: unknown<br />

wfmACPIPowerStateUnknown<br />

ACPI Power State: unknown)<br />

wfmACPIPowerDown<br />

ACPI Power down<br />

wfmWatchdogTimerExpired<br />

Watchdog: Timer Expired<br />

wfmWatchdogHardReset<br />

Watchdog: Hard Reset<br />

wfmWatchdogPowerDown<br />

Watchdog: Power Down<br />

wfmWatchdogPowerCycle<br />

Watchdog: Power Cycle<br />

wfmWatchdogHardwareWatchd<br />

ogExpired<br />

Watchdog: Hardware Watchdog<br />

expired<br />

wfmWatchdogTimerInterrupt<br />

Watchdog: Timer Interrupt<br />

wfmSystemEventlogAboveWar<br />

ningLevel<br />

System Eventlog above warning<br />

level<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

2256646 INFORMAT<br />

IONAL<br />

2256647 INFORMAT<br />

IONAL<br />

2256648 INFORMAT<br />

IONAL<br />

2256649 INFORMAT<br />

IONAL<br />

2256650 INFORMAT<br />

IONAL<br />

2256651 INFORMAT<br />

IONAL<br />

2256652 INFORMAT<br />

IONAL<br />

2256653 INFORMAT<br />

IONAL<br />

2256654 INFORMAT<br />

IONAL<br />

2256710 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

2322176 CRITICAL %s<br />

2322177 CRITICAL %s<br />

2322178 CRITICAL %s<br />

2322179 CRITICAL %s<br />

2322180 CRITICAL %s<br />

2322184 CRITICAL %s<br />

2490711 INFORMAT<br />

IONAL<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

107


108<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmSELAlmostFilledUp<br />

SEL almost filled up<br />

wfmLANHeartbeatLost<br />

LAN Heartbeat lost<br />

wfmLANHeartbeat<br />

LAN Heartbeat<br />

wfmSensorAccessDegraded<br />

Sensor access degraded<br />

wfmControllerAccessDegraded<br />

OrUnavailable<br />

Controller access degraded or<br />

unavailable<br />

wfmManagementControllerOffl<br />

ine<br />

Management Controller off-line<br />

wfmManagementControllerUna<br />

vailable<br />

Management Controller<br />

unavailable<br />

wfmBatteryLowpredictiveFailu<br />

re<br />

Battery low (predictive failure)<br />

wfmBatteryFailed<br />

Battery failed<br />

wfmBatteryPresenceDetected<br />

Battery presence detected<br />

wfmSESSIONActivated<br />

SESSION activated<br />

wfmSESSIONDeactivated<br />

SESSION De-activated<br />

wfmHWChangeDetected<br />

HW change detected<br />

wfmFWOrSWChangeDetected<br />

FW or SW change detected<br />

wfmHWIncompatibilityDetected<br />

HW incompatibility detected<br />

wfmFWOrSWIncompatibilityD<br />

etected<br />

FW or SW incompatibility<br />

detected<br />

wfmInvalidunsupportedHWVer<br />

sionDetected<br />

Invalid/unsupported HW<br />

version detected<br />

wfmInvalidunsupportedFWOrS<br />

WVersionDetected<br />

Invalid/unsupported FW or SW<br />

version detected<br />

wfmHWChangeSuccessful<br />

HW change successful<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

2518871 INFORMAT<br />

IONAL<br />

2584320 INFORMAT<br />

IONAL<br />

2584321 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

2649856 MINOR %s<br />

2649857 MAJOR %s<br />

2649858 MAJOR %s<br />

2649859 CRITICAL %s<br />

2715392 MINOR %s<br />

2715393 MAJOR %s<br />

2715394 INFORMAT<br />

IONAL<br />

2780928 INFORMAT<br />

IONAL<br />

2780929 INFORMAT<br />

IONAL<br />

2846464 INFORMAT<br />

IONAL<br />

2846465 INFORMAT<br />

IONAL<br />

2846466 INFORMAT<br />

IONAL<br />

2846467 INFORMAT<br />

IONAL<br />

2846468 INFORMAT<br />

IONAL<br />

2846469 INFORMAT<br />

IONAL<br />

2846470 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmFWOrSWChangeSuccessf<br />

ul<br />

FW or SW change successful<br />

wfmHWChangeFailed<br />

HW change failed<br />

wfmFWOrSWChangeFailed<br />

FW or SW change failed<br />

wfmOEMEventlogEntryC0<br />

OEM Eventlog Entry (C0)<br />

wfmOEMEventlogEntryC1Stat<br />

eDeAsserted<br />

OEM Eventlog Entry (C1):<br />

State DeAsserted<br />

wfmOEMEventlogEntryC1Stat<br />

eAsserted<br />

OEM Eventlog Entry (C1):<br />

State Asserted<br />

wfmOEMEventlogEntryC1<br />

OEM Eventlog Entry (C1)<br />

wfmOEMEventlogEntryC2<br />

OEM Eventlog Entry (C2)<br />

wfmOEMEventlogEntryC3Stat<br />

eDeAsserted<br />

OEM Eventlog Entry (C3):<br />

State DeAsserted<br />

wfmOEMEventlogEntryC3Stat<br />

eAsserted<br />

OEM Eventlog Entry (C3):<br />

State Asserted<br />

wfmOEMEventlogEntryC3<br />

OEM Eventlog Entry (C3)<br />

wfmOEMEventlogEntryC4<br />

OEM Eventlog Entry (C4)<br />

wfmOEMEventlogEntryC5<br />

OEM Eventlog Entry (C5)<br />

wfmOEMEventlogEntryC6<br />

OEM Eventlog Entry (C6)<br />

wfmOEMEventlogEntryC7<br />

OEM Eventlog Entry (C7)<br />

wfmRSBS2ConsecutiveIllegal<br />

RemoteManagementLogins<br />

RSB S2: Consecutive illegal<br />

remote management logins<br />

wfmRSBS2RemoteManagemen<br />

tUserLogin<br />

RSB S2: Remote management<br />

user login<br />

wfmRSBS2RemoteManagemen<br />

tUserLogout<br />

RSB S2: Remote management<br />

user logout<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

2846471 INFORMAT<br />

IONAL<br />

2879238 INFORMAT<br />

IONAL<br />

2879239 INFORMAT<br />

IONAL<br />

12611328 INFORMAT<br />

IONAL<br />

12649216 INFORMAT<br />

IONAL<br />

12649217 INFORMAT<br />

IONAL<br />

12676864 INFORMAT<br />

IONAL<br />

12742400 INFORMAT<br />

IONAL<br />

12780288 INFORMAT<br />

IONAL<br />

12780289 INFORMAT<br />

IONAL<br />

12807936 INFORMAT<br />

IONAL<br />

12873472 INFORMAT<br />

IONAL<br />

12939008 INFORMAT<br />

IONAL<br />

13004544 INFORMAT<br />

IONAL<br />

13070080 INFORMAT<br />

IONAL<br />

13135616 INFORMAT<br />

IONAL<br />

13135617 INFORMAT<br />

IONAL<br />

13135618 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

v<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

109


110<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmRSBS2RemoteManagemen<br />

tUserAutologout<br />

RSB S2: Remote management<br />

user auto-logout<br />

wfmRSBS2RemoteManagemen<br />

tUserConnectionLost<br />

RSB S2: Remote management<br />

user connection lost<br />

wfmRSBS2RemoteManagemen<br />

tUserDialbackFailed<br />

RSB S2: Remote management<br />

user dialback failed<br />

wfmRSBS2IntegratedRemoteA<br />

ssistantConfigurationResetToD<br />

efaults<br />

RSB S2: Integrated Remote<br />

Assistant configuration reset to<br />

defaults<br />

wfmRemoteMgrLoginFailed<br />

Remote mgr login failed<br />

wfmRSBS2RemoteinitiatedCtrl<br />

AltDel<br />

RSB S2: Remote-initiated<br />

<br />

wfmRemoteMgrLogoutFailed<br />

Remote mgr logout failed<br />

wfmRSBS2RemoteinitiatedRes<br />

et<br />

RSB S2: Remote-initiated reset<br />

wfmRSBS2RemoteinitiatedPo<br />

werCycle<br />

RSB S2: Remote-initiated<br />

power cycle<br />

wfmRSBS2RemoteinitiatedPo<br />

werDown<br />

RSB S2: Remote-initiated<br />

power down<br />

wfmRSBS2RemoteinitiatedPo<br />

werUp<br />

RSB S2: Remote-initiated<br />

power up<br />

wfmRSBS2AutomaticPowerSh<br />

utdownDueToCriticalCondition<br />

RSB S2: Automatic power<br />

shutdown due to critical<br />

condition<br />

wfmRSBS2FrontPanelPowerD<br />

own<br />

RSB S2: Front panel power<br />

down<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

13135619 INFORMAT<br />

IONAL<br />

13135620 INFORMAT<br />

IONAL<br />

13135621 INFORMAT<br />

IONAL<br />

13135622 INFORMAT<br />

IONAL<br />

13135633 INFORMAT<br />

IONAL<br />

13201152 INFORMAT<br />

IONAL<br />

13135634 INFORMAT<br />

IONAL<br />

13201153 INFORMAT<br />

IONAL<br />

13201154 INFORMAT<br />

IONAL<br />

13201155 INFORMAT<br />

IONAL<br />

13201156 INFORMAT<br />

IONAL<br />

13201157 INFORMAT<br />

IONAL<br />

13201158 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmRSBS2AutomaticGraceful<br />

Shutdown<br />

RSB S2: Automatic graceful<br />

shutdown<br />

wfmRSBS2RemoteinitiatedGra<br />

cefulShutdown<br />

RSB S2: Remote-initiated<br />

graceful shutdown<br />

wfmRSBS2RemoteManagemen<br />

tUserPageModemError<br />

RSB S2: Remote management<br />

user page: Modem error<br />

wfmRSBS2RemoteManagemen<br />

tUserPageNoConnection<br />

RSB S2: Remote management<br />

user page: No connection<br />

wfmRSBS2RemoteManagemen<br />

tUserTAPPageNoIDPrompt<br />

RSB S2: Remote management<br />

user TAP page: No ID= prompt<br />

wfmRSBS2RemoteManagemen<br />

tUserTAPPageNoMessageGoah<br />

ead<br />

RSB S2: Remote management<br />

user TAP page: No message goahead<br />

wfmRSBS2RemoteManagemen<br />

tUserTAPPageMessageNotAcc<br />

epted<br />

RSB S2: Remote management<br />

user TAP page: Message not<br />

accepted<br />

wfmRSBS2RemoteManagement<br />

UserEmailNotificationFailed<br />

RSB S2: Remote management<br />

user Email notification failed<br />

wfmRSBS2RemoteCtrlCardMe<br />

moryDiagStarted<br />

RSB S2: Remote Ctrl. Card<br />

Memory diag. started<br />

wfmRSBS2RemoteCtrlCardMe<br />

moryDiagStoppedOK<br />

RSB S2: Remote Ctrl. Card<br />

Memory diag. stopped OK<br />

wfmRSBS2RemoteCtrlCardMe<br />

moryDiagStoppedByUser<br />

RSB S2: Remote Ctrl. Card<br />

Memory diag. stopped by user<br />

wfmRSBS2RemoteCtrlCardMe<br />

moryDiagStoppedWithError<br />

RSB S2: Remote Ctrl. Card<br />

Memory diag. stopped with<br />

Error<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

13201159 INFORMAT<br />

IONAL<br />

13201160 INFORMAT<br />

IONAL<br />

13266689 INFORMAT<br />

IONAL<br />

13266690 INFORMAT<br />

IONAL<br />

13266691 INFORMAT<br />

IONAL<br />

13266692 INFORMAT<br />

IONAL<br />

13266693 INFORMAT<br />

IONAL<br />

13266694 INFORMAT<br />

IONAL<br />

13332224 INFORMAT<br />

IONAL<br />

13332225 INFORMAT<br />

IONAL<br />

13332226 INFORMAT<br />

IONAL<br />

13332227 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

111


112<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmRSBS2RemoteCtrlCardSta<br />

rted<br />

RSB S2: Remote Ctrl. Card<br />

Started<br />

wfmRSBS2RemoteCtrlCardInt<br />

ernalError<br />

RSB S2: Remote Ctrl. Card<br />

Internal error<br />

wfmRSBS2RemoteCtrlCardFir<br />

mwareUpdated<br />

RSB S2: Remote Ctrl. Card<br />

Firmware updated<br />

wfmRSBS2RemoteCtrlCardBat<br />

teryLow<br />

RSB S2: Remote Ctrl. Card<br />

Battery low<br />

wfmRSBS2RemoteCtrlCardBat<br />

teryDisconnected<br />

RSB S2: Remote Ctrl. Card<br />

Battery disconnected<br />

wfmRSBS2RemoteCtrlCardCo<br />

nfigSetToDefault<br />

RSB S2: Remote Ctrl. Card<br />

Config set to default<br />

wfmRSBS2RemoteCtrlCardIP<br />

AddressChanged<br />

RSB S2: Remote Ctrl. Card IP<br />

Address Changed<br />

wfmRSBS2RemoteCtrlCardBat<br />

teryDefective<br />

RSB S2: Remote Ctrl. Card<br />

Battery Defective<br />

wfmRSBS2RemoteCtrlCardBat<br />

teryTooOld<br />

RSB S2: Remote Ctrl. Card<br />

Battery Too Old<br />

wfmRSBS2RemoteCtrlCardCer<br />

tificateExpiresInDays<br />

RSB S2: Remote Ctrl. Card<br />

Certificate Expires in Days<br />

wfmFSCRompilotError<br />

FSC: Rompilot error<br />

wfmNoMemIdentInfo<br />

No memory module ident info<br />

wfmFSCNonFSCMemoryMod<br />

uleDetected<br />

FSC: Non FSC memory module<br />

detected<br />

wfmFSCMemoryModuleRepla<br />

ced<br />

FSC: Memory module replaced<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

13397760 INFORMAT<br />

IONAL<br />

13397761 INFORMAT<br />

IONAL<br />

13397762 INFORMAT<br />

IONAL<br />

13397763 INFORMAT<br />

IONAL<br />

13397764 INFORMAT<br />

IONAL<br />

13397765 INFORMAT<br />

IONAL<br />

13397766 INFORMAT<br />

IONAL<br />

13397767 INFORMAT<br />

IONAL<br />

13397768 INFORMAT<br />

IONAL<br />

13397769 INFORMAT<br />

IONAL<br />

14708640 INFORMAT<br />

IONAL<br />

14774016 INFORMAT<br />

IONAL<br />

14774176 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

%s<br />

14774177 MAJOR %s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Remarks


TRAP-TYPE/<br />

Alarm type<br />

wfmFSCSystemPoweredOnRea<br />

son<br />

FSCSystem powered on reason<br />

wfmFSCNoUsableCPU<br />

FSC: No usable CPU<br />

wfmFSCSystemConfigurationD<br />

ataError<br />

FSC: System configuration<br />

Data error<br />

wfmFSCResourceConflict<br />

FSC: Resource Conflict<br />

wfmFSCIRQNotConfigured<br />

FSC: IRQ not configured<br />

wfmFSCDeviceNodeAllocation<br />

Error<br />

FSC: Device node allocation<br />

error<br />

wfmFSCExpansionROMSlotN<br />

otInitialized<br />

FSC: Expansion ROM Slot not<br />

initialized<br />

wfmFSCFanONRunning<br />

FSC: Fan ON, running<br />

wfmFSCFanFailed<br />

FSC: Fan failed<br />

wfmFSCFanPrefailure<br />

FSC: Fan pre-failure<br />

wfmFSCRedundantFanFailed<br />

FSC: Redundant fan failed<br />

wfmFSCFanNotManageable<br />

FSC: Fan not manageable<br />

wfmFSCFanNotInstalled<br />

FSC: Fan not installed<br />

wfmFSCPowerSupplyNotPrese<br />

nt<br />

FSC: Power supply not present<br />

wfmFSCPowerSupplyOK<br />

FSC: Power supply OK<br />

wfmFSCPowerSupplyFailed<br />

FSC: Power supply Failed<br />

wfmFSCPowerSupplyACFail<br />

FSC: Power supply AC fail<br />

wfmFSCPowerSupplyDCFail<br />

FSC: Power supply DC fail<br />

wfmFSCPowerSupplyCritTemp<br />

FSC: Power supply Crit. Temp.<br />

wfmFSCPowerSupplyNotMana<br />

geable<br />

FSC: Power supply not<br />

manageable<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

Level of<br />

importance<br />

14839712 INFORMAT<br />

IONAL<br />

%s<br />

14905090 CRITICAL %s<br />

14970624 MAJOR %s<br />

14970785 MAJOR %s<br />

14970786 MAJOR %s<br />

14970787 MAJOR %s<br />

14970788 MAJOR %s<br />

15101696 INFORMAT<br />

IONAL<br />

%s<br />

15101697 CRITICAL %s<br />

15101698 MAJOR %s<br />

15101699 MAJOR %s<br />

15101700 INFORMAT<br />

IONAL<br />

15101701 INFORMAT<br />

IONAL<br />

15232768 INFORMAT<br />

IONAL<br />

15232769 INFORMAT<br />

IONAL<br />

%s<br />

%s<br />

%s<br />

%s<br />

15232770 MAJOR %s<br />

15232771 CRITICAL %s<br />

15232772 MAJOR %s<br />

15232773 MAJOR %s<br />

15232774 INFORMAT<br />

IONAL<br />

%s<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

B.36 INTEL-WFM-MIB (WFM.mib )<br />

Remarks<br />

113


114<br />

B <strong>Trap</strong> <strong>List</strong><br />

TRAP-TYPE/<br />

Alarm type<br />

wfmFSCPowerSupplyRedunda<br />

ncyPresent<br />

FSC: Power supply redundancy<br />

present<br />

wfmFSCPowerSupplyRedunda<br />

ncyLost<br />

FSC: Power supply redundancy<br />

lost<br />

B.37 EM4513-MIB (unicorn-trap.mib)<br />

<strong>Trap</strong> from EM4513-MIB.<br />

TRAP-TYPE/<br />

Alarm type<br />

swTemperatureOverHeat<strong>Trap</strong><br />

Temperature over heat<br />

table: INTEL-WFM-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.3183.1.1)<br />

Specific<br />

15298304 INFORMAT<br />

IONAL<br />

%s<br />

15331072 MAJOR %s<br />

table: EM4513-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.259.6.10.39)<br />

Specific<br />

Level of<br />

importance<br />

Level of<br />

importance<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

1 CRITICAL Temperature in chasis is too high.<br />

Remarks<br />

Remarks


B.38 NET-SNMP-MIB (net-snmp.mib)<br />

<strong>Trap</strong>s from Linux Net-SNMP.<br />

TRAP-TYPE/<br />

Alarm type<br />

nsNotifyStart<br />

The agent has started running.<br />

nsNotifyShutdown<br />

The agent is in the process of<br />

being shut down.<br />

nsNotifyRestart<br />

The agent has been restarted.<br />

table: NET-SNMP-MIB <strong>Trap</strong> (ENTERPRISE : enterprises.8072.4)<br />

Specific<br />

Level of<br />

importance<br />

1 INFORMAT<br />

IONAL<br />

2 INFORMAT<br />

IONAL<br />

3 INFORMAT<br />

IONAL<br />

Detailed Messages<br />

(%d: optional number %s: system<br />

variable)<br />

An indication that the agent has started<br />

running.<br />

An indication that the agent is in the<br />

process of being shut down.<br />

An indication that the agent has been<br />

restarted.<br />

B.38 NET-SNMP-MIB (net-snmp.mib)<br />

Remarks<br />

115


B <strong>Trap</strong> <strong>List</strong><br />

116


ServerView V3.60<br />

<strong>Trap</strong> <strong>List</strong><br />

B7FH-3141-01ENZ0-00<br />

Issued on<br />

Issued by<br />

July, 2005<br />

FUJITSU LIMITED<br />

The contents of this manual may be revised without prior notice.<br />

Fujitsu assumes no liability for damages to third party copyrights or other rights<br />

arising from the use of any information in this manual.<br />

No part of this manual may be reproduced in any form without the prior written<br />

permission of Fujitsu.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!