HP ProLiant ML350 Generation 6
HP ProLiant ML350 Generation 6 HP ProLiant ML350 Generation 6
QuickSpecs HP ProLiant ML350 Generation 6Technical SpecificationsSystem UnitTower Dimensions(H x W x D)(with feet/bezel)Rack Dimensions(H x W x D)(with feet/bezel)Tower Weight(approximate)Rack Weight(approximate)Input Requirements(per power supply)18.5 x 8.59 x 23.46 in (47 x 21.8 x 59.6 cm)8.54 x 17.5 x 21.9 in. (21.7 x 44.5 x 55.7cm)Maximum70 lb (31.8 kg)(all hard drives, powersupplies, and processorsinstalled)Minimum(one hard drive, powersupply, and processorinstalled)54 lb (24.5 kg)Maximum66 lb (29.9 kg)(all hard drives, powersupplies, and processorsinstalled)Minimum(one hard drive, powersupply, and processorinstalled)Rated Line Voltage48 lb (21.8 kg)100 to 240 VACRated Input Current 7.1 Amps (at 120VAC) to 3.5 Amps (at 240VAC)Rated Input FrequencyRated Input Power50 to 60 Hz852 WBTU Rating Maximum 460W - 1773 BTU / hr (at 120 VAC), 1715 (at240 VAC)750W - 2892 BTU / hr (at 120 VAC), 2797 (at240 VAC)1200W - 3530 BTU / hr (at 120 VAC), 4600(at 240 VAC)Power SpecificationsTo review typical system power ratings use the HP Power Advisor whichis available via the online tool located at URL:www.hp.com/go/proliant-energy-efficientPower Supply Output(per power supply)System InletTemperature- Click on the system of interest. Example: ML350 G6- Follow the instructions of the next screens.Rated Steady-StatePowerMaximum Peak PowerOperating460(750) W (at 100 VAC),460(750) W (at 200 VAC)460(750) W (at 100 VAC),460(750) W (at 200 VAC)NOTE: See Power Supply Specificationstables for complete details on 460W PSU andoptional 750W and 1200W Power SupplyOptions.10° to 35°C (50° to 95°F) at sea level with analtitude derating of 1.0°C per every 305 m(1.8°F per every 1000 ft) above sea level to aDA - 13241 Worldwide QuickSpecs — Version 51 — 9/9/2011 Page 50
QuickSpecs HP ProLiant ML350 Generation 6Technical SpecificationsRelative Humidity(non-condensing)Non-operatingmaximum of 3050 m (10,000 ft), no directsustained sunlight. Maximum rate of changeis 10°C/hr (18°F/hr). The upper limit may belimited by the type and number of optionsinstalled.System performance may be reduced ifoperating with a fan fault or above 30°C(86°F).-30° to 60°C (-22° to 140°F). Maximum rate ofchange is 20°C/hr (36°F/hr).Operating 10 to 90% relative humidity (Rh), 28°C(82.4°F) maximum wet bulb temperature, noncondensing.Non-operating5 to 95% relative humidity (Rh), 38.7°C(101.7°F) maximum wet bulb temperature,non-condensing.Altitude Operating 3050 m (10,000 ft). This value may be limitedby the type and number of options installed.Maximum allowable altitude change rate is457 m/min (1500 ft/min).Acoustic NoiseEmissionsClassification (EMC)Non-operating9144 m (30,000 ft). Maximum allowablealtitude change rate is 457 m/min (1500ft/min).Listed are the declared A-Weighted sound power levels (LWAd) anddeclared average bystander position A-Weighted sound pressure levels(LpAm) when the product is operating in a 23°C ambient environment.Noise emissions were measured in accordance with ISO 7779 (ECMA74) and declared in accordance with ISO 9296 (ECMA 109).IdleOperatingL WAdL pAmL WAdL pAm4.7 B (1P Non-Redundant)4.6 B (2P Redundant)32.48dB (1P Non-Redundant)31.18dB (2P Redundant)4.8 B (1P Non-Redundant)4.7 B (2P Redundant)32.39dB (1P Non-Redundant)31.62dB (2P Redundant)NOTE: The Listed sound levels apply to standard shippingconfigurations. Additional options may result in increased sound levels.FCC RatingClass BNormative Standards CISPR 22; EN55022; EN55024; FCC CFR 47,Pt 15; ICES-003; CNS13438; GB9254;K22;K24; EN 61000-3-2; EN 61000-3-3; EN60950-1; IEC 60950-1NOTE: Product conformance to cited product specifications is based onsample (type) testing, evaluation, or assessment. This product or familyof products is eligible to bear the appropriate compliance logos andstatements.DA - 13241 Worldwide QuickSpecs — Version 51 — 9/9/2011 Page 51
- Page 1 and 2: QuickSpecs HP ProLiant ML350 Genera
- Page 3 and 4: QuickSpecs HP ProLiant ML350 Genera
- Page 5 and 6: QuickSpecs HP ProLiant ML350 Genera
- Page 7 and 8: QuickSpecs HP ProLiant ML350 Genera
- Page 9 and 10: QuickSpecs HP ProLiant ML350 Genera
- Page 11 and 12: QuickSpecs HP ProLiant ML350 Genera
- Page 13 and 14: QuickSpecs HP ProLiant ML350 Genera
- Page 15 and 16: QuickSpecs HP ProLiant ML350 Genera
- Page 17 and 18: QuickSpecs HP ProLiant ML350 Genera
- Page 19 and 20: QuickSpecs HP ProLiant ML350 Genera
- Page 21 and 22: QuickSpecs HP ProLiant ML350 Genera
- Page 23 and 24: QuickSpecs HP ProLiant ML350 Genera
- Page 25 and 26: QuickSpecs HP ProLiant ML350 Genera
- Page 27 and 28: QuickSpecs HP ProLiant ML350 Genera
- Page 29 and 30: QuickSpecs HP ProLiant ML350 Genera
- Page 31 and 32: QuickSpecs HP ProLiant ML350 Genera
- Page 33 and 34: QuickSpecs HP ProLiant ML350 Genera
- Page 35 and 36: QuickSpecs HP ProLiant ML350 Genera
- Page 37 and 38: QuickSpecs HP ProLiant ML350 Genera
- Page 39 and 40: QuickSpecs HP ProLiant ML350 Genera
- Page 41 and 42: QuickSpecs HP ProLiant ML350 Genera
- Page 43 and 44: QuickSpecs HP ProLiant ML350 Genera
- Page 45 and 46: QuickSpecs HP ProLiant ML350 Genera
- Page 47 and 48: QuickSpecs HP ProLiant ML350 Genera
- Page 49: QuickSpecs HP ProLiant ML350 Genera
- Page 53: QuickSpecs HP ProLiant ML350 Genera
QuickSpecs <strong>HP</strong> <strong>ProLiant</strong> <strong>ML350</strong> <strong>Generation</strong> 6Technical SpecificationsSystem UnitTower Dimensions(H x W x D)(with feet/bezel)Rack Dimensions(H x W x D)(with feet/bezel)Tower Weight(approximate)Rack Weight(approximate)Input Requirements(per power supply)18.5 x 8.59 x 23.46 in (47 x 21.8 x 59.6 cm)8.54 x 17.5 x 21.9 in. (21.7 x 44.5 x 55.7cm)Maximum70 lb (31.8 kg)(all hard drives, powersupplies, and processorsinstalled)Minimum(one hard drive, powersupply, and processorinstalled)54 lb (24.5 kg)Maximum66 lb (29.9 kg)(all hard drives, powersupplies, and processorsinstalled)Minimum(one hard drive, powersupply, and processorinstalled)Rated Line Voltage48 lb (21.8 kg)100 to 240 VACRated Input Current 7.1 Amps (at 120VAC) to 3.5 Amps (at 240VAC)Rated Input FrequencyRated Input Power50 to 60 Hz852 WBTU Rating Maximum 460W - 1773 BTU / hr (at 120 VAC), 1715 (at240 VAC)750W - 2892 BTU / hr (at 120 VAC), 2797 (at240 VAC)1200W - 3530 BTU / hr (at 120 VAC), 4600(at 240 VAC)Power SpecificationsTo review typical system power ratings use the <strong>HP</strong> Power Advisor whichis available via the online tool located at URL:www.hp.com/go/proliant-energy-efficientPower Supply Output(per power supply)System InletTemperature- Click on the system of interest. Example: <strong>ML350</strong> G6- Follow the instructions of the next screens.Rated Steady-StatePowerMaximum Peak PowerOperating460(750) W (at 100 VAC),460(750) W (at 200 VAC)460(750) W (at 100 VAC),460(750) W (at 200 VAC)NOTE: See Power Supply Specificationstables for complete details on 460W PSU andoptional 750W and 1200W Power SupplyOptions.10° to 35°C (50° to 95°F) at sea level with analtitude derating of 1.0°C per every 305 m(1.8°F per every 1000 ft) above sea level to aDA - 13241 Worldwide QuickSpecs — Version 51 — 9/9/2011 Page 50