34 | <strong>Air</strong> cooled Chiller & Heat Pumps<strong>Air</strong> CooledHeat PumpAQVH 85–14081–129 kW 92–146 kWHFC 410AScrollTechnical feature6 sizes.Cooling capacity from 81 to 137 kW.Heating capacity from 92 to 146 kW.• 4 versions:STD (Standard);HSE (High Seasonal Efficiency);HT (High Temperature);HPF (High Pressure Fans) .• 2 acoustic versions:BLN (Basic Low Noise) and ELN (Extra Low Noise).Two refrigerant circuit.Scroll compressors.Microprocessor control.Low operating water content in the plant.• Electronic expansion valve as standard.Accessories and options• Hydrokit with 1 or 2 pumps with •ot without buffer tank.Desuperheater.Coils treatments.Unit protection grilles.Sofstart.BMS interface.• Overload protection forcompressors.Automatic circuit breaker.Fan speed control.• Flow switch (standard).Mechanical gauges kit.Pressure switch.Water filter.Power factor corrector capacitors.• Compressors acoustic boxas standard.• Sequence phases controlas standard.Compressors jackets.• Electric heater inside buffer tankfor additional heating.Operating limitAQVH Min MaxLeaving water temperature (cooling)Water °С +5 +18Water with glycol °С -8 +18Leaving water temperature (heating) °С +20 +55<strong>Air</strong> temperature (heating) °С -15 +20BLN °С +5 +47<strong>Air</strong> temperature (cooling)ELN °С -18 +44HT °С -18+50 ( 85-115)+47 (125-140)External static pressureStandard fans Pa 0High Pressure Fans (HPF) Pa < 120
<strong>Air</strong> cooled Chiller & Heat Pumps |35Technical feature AQVH 85–140 BLNModel AQVH BLN 85 95 105 115 125 140Cooling capacity (1) kW 81,2 90,2 99,2 107,2 116,2 129,6Power input (2) kW 25,1 29,1 31,8 34,5 38,0 42,6GROSS EER 2,99 2,89 2,93 2,93 2,8 2,82GROSS ESEER 4,18 4,04 4,10 4,10 3,93 3,95GROSS EER HSE 3,09 2,97 3,01 3,00 2,87 2,88GROSS ESEER HSE 4,54 4,37 4,42 4,41 4,22 4,23EER 2,95 2,85 2,89 2,90 2,78 2,78ESEER 3,78 3,81 3,86 3,96 3,69 3,77EER HSE 3,05 2,94 2,97 2,96 2,84 2,84ESEER HSE 4,21 4,14 4,27 4,28 3,96 4,03Heating capacity (3) kW 91,5 102,4 110,7 118,6 133,9 146,3Power input kW 24,4 28,0 30,0 32,7 37,1 40,8GROSS COP 3,45 3,40 3,45 3,41 3,31 3,31GROSS COP HSE 3,57 3,50 3,55 3,50 3,39 3,39COP 3,39 3,23 3,29 3,26 3,13 3,14COP HSE 3,54 3,47 3,52 3,47 3,36 3,36Number of refrigerant circuits 2 2 2 2 2 2Part load steps % 0-25-50-75-1000-25-50-75-1000-24-47-74-100Power supply V/ph/Hz 400/3/50Startup typeDirect0-25-50-75-1000-22-43-72-1000-25-50-75-100RefrigerantTypeHFC 410ACharge kW 21,1 23,4 25,8 27,9 30,2 33,7CompressorQty 4 4 4 4 4 4TypeScrollCrankcase heater W 90 90 90 90 90 90EvaporatorQty 1 1 1 1 1 1Type Plate exchanger AISI 316Water flow l/h 13.967 15.508 17.060 18.431 19.987 22.288Antifreeze heater W 130 130 130 130 130 130Connection typeMale gas threadedInlet/outlet diameter inch 2½” 2½” 2½” 2½” 2½” 2½”CondenserQty 2 2 2 2 2 2Frontal surface mm 2.000x1.200 2.000x1.200 2.000x1.200 2.000x1.200 2.600x1.200 2.600x1.200FanQty 2 2 2 2 2 2<strong>Air</strong> flow m 3 /h 34.700 34.700 34.050 33.400 44.500 43.200Speed rpm/min 690 690 690 690 900 900Power input kW 2,1 2,1 2,1 2,1 3,4 3,4WeightShipping kg 1.065 1.080 1.122 1.153 1.196 1.270Operating kg 1.090 1.105 1.149 1.180 1.227 1.301DimensionLength mm 2.555 2.555 2.555 2.555 3.155 3.155Width mm 1.095 1.095 1.095 1.095 1.095 1.095Height mm 2.185 2.185 2.185 2.185 2.185 2.185Acoustical dataSound power level (4) dB(A) 85 85 85 85 89 89Sound pressure level (5) dB(A) 53 53 53 53 57 57Sound power level HSE (3) dB(A) 92 92 92 92 95 95Sound pressure level HSE (4) dB(A) 60 60 60 60 63 63(1) Data based on 7°C leaving chilled water temperature and 35°C ambient air temperature.(2) Compressors only.(3) Data based on 45°C leaving hot water temperature and 7°C ambient air temperature.(4) Sound power values in accordance with ISO 3744.(5) The sound pressure is calculated from a distance of 10 m.GROSS EER: efficiency in cooling mode without considering the available head of the pump or the pressure drop of the heat exchanger.EER: efficiency in cooling unit according to EN14511-2011.
- Page 4 and 5: 22 | SystemairSystemair worldwideSk
- Page 6 and 7: 4| Product rangeProduct rangeSystem
- Page 8 and 9: 6 | ApplicationsApplicationsOffices
- Page 14 and 15: 12 | Air cooled chiller & Heat Pump
- Page 16 and 17: 14 | Air cooled chiller & Heat Pump
- Page 18: 16 | Air cooled chiller & Heat Pump
- Page 21 and 22: Air cooled chiller & Heat Pumps |19
- Page 23 and 24: Air cooled chiller & Heat Pumps |21
- Page 25 and 26: Air cooled chiller & Heat Pumps |23
- Page 27 and 28: Air cooled chiller & Heat Pumps |25
- Page 29 and 30: Air cooled chiller & Heat Pumps |27
- Page 38: 36 | Air cooled Chiller & Heat Pump
- Page 41 and 42: Air cooled Chiller & Heat Pumps |39
- Page 44 and 45: 42 | Air cooled Chiller & Heat Pump
- Page 46 and 47: 44 | Air cooled Chiller & Heat Pump
- Page 48 and 49: 46 | Air cooled Chiller & Heat Pump
- Page 50 and 51: 48 | Air cooled Chiller & Heat Pump
- Page 52 and 53: 50 | Air cooled Chiller & Heat Pump
- Page 54 and 55: 52 | Air cooled Chiller & Heat Pump
- Page 56 and 57: 54 | Air cooled Chiller & Heat Pump
- Page 58 and 59: 56 | Air cooled Chiller & Heat Pump
- Page 60 and 61: 58 | Air cooled Chiller & Heat Pump
- Page 62 and 63: 60 | Air cooled Chiller & Heat Pump
- Page 64 and 65: 62 | Air cooled Chiller & Heat Pump
- Page 66 and 67: 64 | Air cooled Chiller & Heat Pump
- Page 68 and 69: 66 | Air cooled Chiller & Heat Pump
- Page 70 and 71: 68 | Air cooled Chiller & Heat Pump
- Page 72 and 73: 70 | Air cooled Chiller & Heat Pump
- Page 74 and 75: 72 | Air cooled Chiller & Heat Pump
- Page 76 and 77: 74 | Air cooled Chiller & Heat Pump
- Page 78 and 79: 76 | Air cooled Chiller & Heat Pump
- Page 81 and 82:
Air cooled Chiller & Heat Pumps |79
- Page 83 and 84:
Air cooled Chiller & Heat Pumps |81
- Page 85 and 86:
Air cooled Chiller & Heat Pumps |83
- Page 87 and 88:
Water Cooled Chiller,Heat Pump and
- Page 89 and 90:
Water Cooled Chiller, Heat Pump and
- Page 91 and 92:
Water Cooled Chiller, Heat Pump and
- Page 93 and 94:
Water Cooled Chiller, Heat Pump and
- Page 95 and 96:
Water Cooled Chiller, Heat Pump and
- Page 97 and 98:
Water Cooled Chiller, Heat Pump and
- Page 99 and 100:
Water Cooled Chiller, Heat Pump and
- Page 101 and 102:
Water Cooled Chiller, Heat Pump and
- Page 103 and 104:
Water Cooled Chiller, Heat Pump and
- Page 105 and 106:
Water Cooled Chiller, Heat Pump and
- Page 107 and 108:
Hydrokit |1056 83111521241397101 Ta
- Page 109 and 110:
Condensing unitAQC 40-7543-85 kW410
- Page 111 and 112:
Condensing unit |109Technical featu
- Page 113 and 114:
Condensing unit |111Technical featu
- Page 115 and 116:
Condensing unit |113Technical featu
- Page 117 and 118:
Condensing unit |115Technical featu
- Page 119 and 120:
Condensing unit |117Operating limit
- Page 121 and 122:
Condensing unit |119Technical featu
- Page 123 and 124:
Condensing unit |121Technical featu
- Page 125 and 126:
Condensing unit |123Technical featu
- Page 127 and 128:
Condensing unit |125Technical featu
- Page 129 and 130:
Close controlCW 21-2025-190.8 kWChi
- Page 131 and 132:
Close control |129Close controlwith
- Page 133:
Close control |131Remote condenserf
- Page 136 and 137:
134 | Water TerminalsCentrifugal fa
- Page 138 and 139:
136 | Water TerminalsCentrifugal fa
- Page 140 and 141:
138 | Water TerminalsCentrifugal fa
- Page 142 and 143:
140 | Water TerminalsWater Cassette
- Page 144 and 145:
142 | Water TerminalsDuctable fan c
- Page 146 and 147:
144 | Water TerminalsDuctable fan c
- Page 148 and 149:
146 | Water TerminalsWall-mounted f
- Page 150 and 151:
148 | Water TerminalsChilled BeamCI
- Page 152 and 153:
150 | Water TerminalsChilled BeamST
- Page 154:
Systemair AC srlVia XXV Aprile, 292