acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ... acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

biometrics.nist.gov
from biometrics.nist.gov More from this publisher
11.07.2015 Views

ANSI/NIST-ITL 1-2011 - UPDATE 2013 DRAFT VERSION• The first information item is the type of device / TYP. It is optional. A typicalentry may be 'metal plate in right arm' or 'external leg brace for left leg'• The second information item is the device manufacturer / MFG. It is optional.• The third information item is the device make / MAK. It is optional.• The fourth information item is the device model / MOD. It is optional.• The fifth information item is the device serial number / SER. It is optional.• The sixth information item is optional. It is any comment / COM concerningthe device.[

ANSI/NIST-ITL 1-2011 - UPDATE 2013 DRAFT VERSIONThe ACN is a positive integer that uniquely refers to a particular instance of Record Type-21.It is a positive integer, numbered sequentially beginning at one and incremented for eachinstance of Record Type-21.8.21.11 Field 21.046: Subject / SUB[2013n>]This field is optional. This field is particularly useful if the image is obtained from adeceased person. However, its use is not limited to such circumstances. SUB is comprisedof the following information items:• The first information item is mandatory if this field is present. It is subjectstatus code / SSC. Possible entries are:0 = Status of individual unknown1 = Data obtained from a living person – such as a victim orpersons unable to identify themselves2 = Data obtained from a decedent – such as an unknowndeceased• The second information item shall be entered if SSC is 2. It is subject bodystatus code / SBSC. Its purpose is to indicate whether the information relates toan entire corpse or a separate body part. The numeric value is selected from thedescriptors below:1 = Whole2 = Fragment• The third information item shall be entered if SSC is 2. It is subject body classcode/ SBCC. The numeric value is selected from the descriptors below:1 = Natural Tissue2 = Decomposed3 = Skeletal8.21.12 Field 21.047: Capture organization name / CONThis field is optional. Note that this can be different from the agency entered in Field19.004: Source agency / SRC and Field 19.993: Source agency name / SAN. SRC andSAN describe the agency that created the record. Since the record may have beenforwarded by another agency to the final destination, Field 1.008 Originating agencyidentifier / ORI is used to indicate the transmitting organization. See Section 7.6 for412

ANSI/<strong>NIST</strong>-ITL 1-<strong>2011</strong> - UPDATE 2013 DRAFT VERSION• The first in<strong>for</strong>mation item is the type of device / TYP. It is optional. A typicalentry may be 'metal plate in right arm' or 'external leg brace <strong>for</strong> left leg'• The second in<strong>for</strong>mation item is the device manufacturer / MFG. It is optional.• The third in<strong>for</strong>mation item is the device make / MAK. It is optional.• The fourth in<strong>for</strong>mation item is the device model / MOD. It is optional.• The fifth in<strong>for</strong>mation item is the device serial number / SER. It is optional.• The sixth in<strong>for</strong>mation item is optional. It is any comment / COM concerningthe device.[

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!