11.07.2015 Views

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ANSI/<strong>NIST</strong>-ITL 1-<strong>2011</strong> - UPDATE 2013 DRAFT VERSIONValue Description Spectrumcases may extend to the peri-ocular region.RED Red portion of visible full-spectrum illuminationNOTE: Red light visible images cannot usually be matchedApprox. 620–750 nmagainst near-infrared images because no detail, noisy detail, ordifferent detail, of the iris texture is present in a red light image.Interoperability between VIS and RED images remains aresearch issue. RED images are supported by this standard <strong>for</strong>supplemental, <strong>for</strong>ensic, and research purposes only. Such usecases may extend to the peri-ocular region.UNDEFINED This value shall be used when the effective spectrum is unknownor unavailable, and is not better described by one of the othervalues.8.17.25 Field 17.026: Iris diameter / IRDThis optional field shall specify the expected iris diameter in pixels. The diameter of theiris should not be less than 140 pixels.8.17.26 Field 17.027: Specified spectrum values / SSVThis field shall only be present if Field 17.025: Effective acquisition spectrum / EAShas a value of 'DEFINED' It is comprised of two in<strong>for</strong>mation items:The first in<strong>for</strong>mation item is is spectrum lower bound / LOW. It is a three or four digitentry indicating the lower frequency bound in nm. (rounded to the nearest 10 nm.).The second in<strong>for</strong>mation item is spectrum upper bound / HIG. It is a three or four digitentry indicating the upper frequency bound in nm. (rounded to the nearest 10 nm.).8.17.27 Field 17.028: Damaged or missing eye / DMEThis optional field shall specify if one or both eyes are unable to provide usable irisimages. The eye position is specified in Field 17.003: Eye Label / ELR . This fieldshall contain a code from Table 90. “UC” should be entered if the eye is physicallypresent, but a usable iris image cannot be captured. An example is when the eye isswollen shut due to injury.Table 90 Missing and damaged eye codesDescriptorMissing or artificial eyeUnable to capture imageCodeMAUC356

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!