11.07.2015 Views

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ANSI/<strong>NIST</strong>-ITL 1-<strong>2011</strong> - UPDATE 2013 DRAFT VERSIONNCICPLASSUDIMThe National Dental <strong>Image</strong> Repository of theNational Crime In<strong>for</strong>mation Center (NCIC) runby the Federal Bureau of Investigation (FBI) 143The DVI System International marketed by PlassData Software A/S 144The Unified Dental Identification Module(UDIM) of the Unified Victim IdentificationSystem (UVIS) 145WinID Dental Identification System 146OtherNoneThe coding system is not listed but is <strong>for</strong>mallydocumentedThe ANSI/ADA Standard No. 1058 – ForensicDental Codes are selected and entered directly.* The second in<strong>for</strong>mation item is the original system version text /OSVT. This item is optional unless ‘Other’ or ‘EDR’ is specified <strong>for</strong>OSNC. It specifies version of the data system that was used in theoriginal coding (such as ‘2012 version’ <strong>for</strong> UVIS/UDIM). WhenOSNC is set to ‘Other’ or ‘EDR’, this in<strong>for</strong>mation item is mandatoryand specifies the official brand name of the software utilized, andoptionally the version number if known. If in<strong>for</strong>mation of the locationof documentation <strong>for</strong> the software is available such as a URL / URI itcan also be included with a text beginning with the word “URL: “.* The third in<strong>for</strong>mation item is the original tooth permanencecategory code / OTPC. It is mandatory. It is used to designate the waythat permanent and deciduous teeth are coded according the systemused to enter the data. Possible values are:0 = Specified by tooth number (e.g. FastID, PLASS). Forsystems such as WinID and UDIM, which internally listthe tooth number with a permanent tooth number but use adeciduous indicator, those two pieces of in<strong>for</strong>mation shallbe combined together to assign the tooth number accordingto ANSI/ADA Standard No. 3950 prior to inclusion in this143In<strong>for</strong>mation is available at http://www.fbi.gov/about-us/cjis/ncic/ncic144In<strong>for</strong>mation is available at http://www.plass.dk/dok/dvi/DVIBrochure.pdf145In<strong>for</strong>mation is available at http://www.nyc.gov/html/ocme/downloads/pdf/Special%20Operations/UVIS%20In<strong>for</strong>mation%20Guide_20090917.pdf146In<strong>for</strong>mation is available at http://winid.com/index.htmMay, 2013 DRAFT VERSION UPDATE 2013 Page 281

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!