11.07.2015 Views

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

acknowledgements for ansi/nist-itl 1-2011 - NIST Visual Image ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ANSI/<strong>NIST</strong>-ITL 1-<strong>2011</strong> - UPDATE 2013 DRAFT VERSIONminutia 77 of type “OTHER”, a value of “1” <strong>for</strong> a ridge ending and a value of “2” <strong>for</strong>a ridge bifurcation.• The sixth in<strong>for</strong>mation item (quality of minutia / QOM) shall range from 1 as aminimum to 100 as a maximum. A value of “0” indicates that no quality value isavailable. Note that this is an integer.8.9.5.13 Field 9.138: M1 ridge count in<strong>for</strong>mation / RCThis optional field shall consist of subfields of three in<strong>for</strong>mation items. It can only appear ifa value of '514' or '515' is entered in CFT of Field 9.126: M1 CBEFF in<strong>for</strong>mation / CBI.For the first subfield:• The first in<strong>for</strong>mation item (ridge count extraction method / REM) shall have avalue of 0, 1 or 2. A “0” indicates that no assumption shall be made about themethod used to extract ridge counts, nor their order in the record. A “1” indicatesthat <strong>for</strong> each center minutiae, ridge count data was extracted to the nearestneighboring minutiae in four quadrants, and ridge counts <strong>for</strong> each center minutia arelisted together. A “2” indicates that <strong>for</strong> each center minutiae, ridge count data wasextracted to the nearest neighboring minutiae in eight octants, and ridge counts <strong>for</strong>each center minutia are listed together.• The remaining two in<strong>for</strong>mation items (filler 1 / FI1 and filler 2 / FI2) of this firstrepeating subfield shall each contain “0”.Subsequent subfields have three in<strong>for</strong>mation items each:• The first in<strong>for</strong>mation item (center minutia index / CMI) is a positive integer.• The second in<strong>for</strong>mation item (neighboring minutia index / NMN) is a positiveinteger. It shall not be equal to CMI.• The third in<strong>for</strong>mation (number of ridges crossed / NRC) is a positive integer.8.9.5.14 Field 9.139: M1 core in<strong>for</strong>mation / CINThis optional field shall consist of one subfield <strong>for</strong> each core present in the original image.It can only appear if a value of '514' or '515' is entered in CFT of Field 9.126: M1 CBEFFin<strong>for</strong>mation / CBI. Each subfield consists of three in<strong>for</strong>mation items.• The first item (‘x’ coordinate / XCC) is an integer in pixel units.• The second item (‘y’ coordinate / YCC) is an integer in pixel units.• The third in<strong>for</strong>mation item (angle of the core / ANGC) is recorded in units of twodegrees. The value shall be between 0 and 179, inclusive.77[2013e>] Corrected typographical error [

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!