Energy targets 677Table 23.11 Heat loss from storage cylinders (insulated with 75 mm glass fibre sited in an ambienttemperature <strong>of</strong> 25 C)Capacity<strong>of</strong> cylinder(litre)WattHeat loss from cylinderMJ/annum150 40 1 300250 55 1 800300 60 2 000450 80 2 500650 100 3 3001000 135 4 3001500 180 5 6002500 250 7 6003000 280 8 8004500 360 11 300It is worthy <strong>of</strong> note that these two components <strong>of</strong> the total are <strong>of</strong>ten <strong>of</strong> the same order<strong>of</strong> magnitude.A knowledge <strong>of</strong> the type <strong>of</strong> building will determine whether heat losses are continuousfor 24 hours per day, as in a hospital, or for some lesser period such as 8 hours per day in aschool. Similarly the days per annum will vary. For intermittent operation, the heat lossfrom storage vessels <strong>and</strong> pipework will continue after the use <strong>of</strong> the system has ceased,perhaps until the water temperature is in equilibrium with the surrounding air dependingupon the period <strong>of</strong> close-down.The heat consumption <strong>of</strong> the water actually drawn <strong>of</strong>f, taken from cold at say 10 Ctohot at say 60 C, will be derived from data <strong>of</strong> water dem<strong>and</strong> <strong>of</strong> comparable buildings.Table 20.4 provides data in this respect. The total <strong>of</strong> the two components will then formthe basis <strong>of</strong> the sum in which the calorific value <strong>of</strong> fuel <strong>and</strong> the seasonal efficiency aretaken into account as for heating (see Table 23.9(b)).Energy targetsThe CIBSE Building Energy Codes set down procedures to enable designers to comparecalculated energy dem<strong>and</strong>s for thermal <strong>and</strong> electrical consumption with energy targets,thereby enabling the most efficient systems to be selected. Code 1 is for heated <strong>and</strong>ventilated buildings <strong>and</strong> Code 2 for air-conditioned buildings is in the drafting process.The procedures given in the Codes require calculations to be based on set formulae <strong>and</strong>on data given in the publications, thereby eliminating possible errors arising from engineeringjudgements. The calculation procedures are not intended to forecast energy consumption,but are a means <strong>of</strong> comparing a calculated dem<strong>and</strong> with an equivalent energytarget.Code 1 requires that for a design to be deemed compliant, the total energy dem<strong>and</strong>must not exceed the total dem<strong>and</strong> target <strong>and</strong> the thermal dem<strong>and</strong>, for heating <strong>and</strong> hotwater, must not exceed the thermal dem<strong>and</strong> target by more than 10%. For air-conditionedbuildings, Code 2 does not set-down energy targets due to the wide variety <strong>of</strong>systems that may be employed: however, it does provide a calculation procedure enablingcomparison <strong>of</strong> the energy dem<strong>and</strong>s <strong>of</strong> different buildings <strong>and</strong> system combinations.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!