Air infiltration 49Table 2.11 Heat requirements for air infiltration through cracks around windowsHeat requirement per unit length <strong>of</strong> opening window joint (W/mK)Without weather strippingWith weather strippingCountry Urban City Country Urban CityHeight <strong>of</strong> building (m)OpenWith windbreaksOpenWith windbreaks6 2.43 1.84 1.22 0.75 1.22 0.92 0.61 0.388 2.60 1.98 1.35 0.81 1.30 0.99 0.67 0.4010 2.71 2.10 1.49 0.94 1.36 1.05 0.72 0.4715 3.00 2.33 1.66 1.12 1.49 1.17 0.83 0.5620 3.19 2.52 1.82 1.27 1.59 1.26 0.91 0.6425 3.35 2.67 1.96 1.40 1.68 1.34 0.98 0.7030 3.49 2.80 2.08 1.52 1.75 1.40 1.04 0.7640 3.73 3.03 2.29 1.72 1.86 1.51 1.14 0.8650 3.92 3.21 2.46 1.90 1.96 1.61 1.23 0.95NoteWind speed 8 m/s, at notional height <strong>of</strong> 10 m in open country, is exceeded for 10% <strong>of</strong> time only. Other wind speeds derived from this datum.A further adjustment, which should properly be applied also to results derived from airchangecalculations, makes a notional allowance for stack effect in tall buildings. Inwinter, the lower floors will have above average infiltration <strong>and</strong> although the upper floorswill have less than the average, the 1986 Guide Section A4 proposes that no allowanceshould be made, in the latter case, by deduction. The essence <strong>of</strong> the method is:. At ground floor level, add the equivalent <strong>of</strong> 1% for each storey in the building; reducethis addition by 2% for each higher floor, i.e. for a 12-storey building add 12% atground floor level, followed by 10% at first floor, decreasing to 2% at fifth floor withno addition thereafter.This last adjustment results from research work* published in 1961 which concludedspecifically that:. Swinging door entrances ± for a particular set <strong>of</strong> conditions ± infiltrate about 25 m 3through a single opening, per person entering or leaving a building, <strong>and</strong> 15 m 3 perperson for a vestibule-type entrance.. Revolving doors under similar conditions infiltrate about 2 m 3 per person, <strong>and</strong> motordriven doors about half that amount.. Adequate heating in winter is required in entrances <strong>and</strong> vestibules at ground floor levelby forced warm air heaters or air curtains, augmented by floor panel heating.The 1999 Guide Section A4 proposes an equation for calculating the pressure differencerelated to vertical height differences <strong>and</strong> hence the airflow through openings.Reference must also be made here to significant problems which have been encounteredwith buildings clad in curtain walling. As may be seen from Figure 2.11, if particular carehas not been taken to seal the structural joint where the cladding passes the edge beam <strong>of</strong>the floor slab, leakage can occur <strong>and</strong> stack effect will cause air to move upwards, floor by* Min, T. C., `Engineering concept <strong>and</strong> design <strong>of</strong> controlling ventilation <strong>and</strong> traffic through entrances intall commercial buildings', JIHVE, 1961.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!