Air humidification 493Withdrawal(a) Cylindrical(b) Panel (section)Figure 17.20 Adsorption filter, single cellAdsorption filter. The service life <strong>of</strong> an activated carbon filter is between 6 months <strong>and</strong> 2years, depending on the type <strong>of</strong> installation <strong>and</strong> the concentration <strong>of</strong> contaminants beingadsorbed. An efficient particulate filter is recommended for use upstream. Normally, thecells are re-chargeable. Typical cell arrangements are shown in Figure 17.20. Thepressure drop across the unit is about 70 Pa <strong>and</strong> the face velocity <strong>of</strong> the order 1.5 m/s.Air humidificationDuring winter months the outside air has a low moisture content <strong>and</strong> when introduced toa conditioned space tends to reduce the relative humidity. To counter this effect, it is <strong>of</strong>tennecessary to introduce moisture into the space to maintain the required conditions forcomfort or for a process.Air humidifiers may be classed as either direct or indirect.Direct types. Introduce moisture into the space to be treated <strong>and</strong> their use is normally limitedto industrial or horticultural applications: these types are outside the scope <strong>of</strong> this book.Indirect types. Introduce moisture into the supply air either at the plant or within theductwork, dependent upon the type <strong>of</strong> system.A further sub-classification <strong>of</strong> the indirect type is storage or non-storage. The storagetypes incorporate a small tankunder the humidifying apparatus from which water isintroduced into the air stream, in one <strong>of</strong> a variety <strong>of</strong> ways. The water level in the tankismaintained by a water supply via a ball valve. With the non-storage type moisture, in theform <strong>of</strong> steam or atomised water particles, is injected directly into the air stream.Concern as to humidifier-related illness has changed the approach to selection <strong>and</strong> use<strong>of</strong> the associated equipment quite radically. Storage-type units are no longer acceptablefor application to systems in hospitals, where steam injection is recommended, a trendseen also in commercial practice. Where storage types exist or are envisaged, particularcare in cleaning, maintenance <strong>and</strong> inspection is required at frequent intervals. Furtherrecommendations relate to the need for biocide treatment <strong>of</strong> the tankwater <strong>and</strong> drainagethere<strong>of</strong> to waste, at regular intervals, preferably daily. The tankmust be drained <strong>and</strong>cleaned when the humidifier is to be out <strong>of</strong> use for any extended period.** CIBSE, Minimising the Risk <strong>of</strong> Legionnaires' Disease, CIBSE Technical Memor<strong>and</strong>um TM13, 1991(revised 2000). CIBSE, Legionellosis (Interpretation <strong>of</strong> Approved Code <strong>of</strong> Practice: The Prevention orControl <strong>of</strong> Legionellosis, CIBSE Guidance Note GN3, 1993.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!