11.07.2015 Views

Book - School of Science and Technology

Book - School of Science and Technology

Book - School of Science and Technology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

440 Ductwork designFlat ovalSt<strong>and</strong>ardfittingCircularFigure 16.4 Flat oval ducting <strong>and</strong> brancheslocking collar into position to provide an `air-tight' joint. Such forms <strong>of</strong> constructionshould be restricted in use strictly to manufacturers' recommendations.Flat oval or spirally wound rectangular ducts are in common use in air-conditioning.These are formed from spirally wound circular ducts to the pr<strong>of</strong>ile illustrated in Figure16.4 <strong>and</strong> are available in sizes from 75 mm 320 mm to 500 mm 1640 mm. A limitedrange <strong>of</strong> st<strong>and</strong>ard tees, bends <strong>and</strong> reducers is made. Such ducts have the advantage <strong>of</strong>being mass produced <strong>and</strong> can be used in conjunction with circular sections where space islimited. Site jointing, as before, is completed by a heat shrink or chemical reaction sleeve.Builders' work ductsThe suggestion is sometimes put forward, in early stages <strong>of</strong> design for a building, thatmain air ducts <strong>and</strong> rising shafts should be constructed as a part <strong>of</strong> the fabric. Thefollowing advantages are claimed for such an expedient:. Cheapness in that the space very <strong>of</strong>ten exists as a structural wind brace or in associationwith one or more lift shafts.. Permanence.. Reduction in heat gains <strong>and</strong> losses, due to the heavy construction as compared withmetal.. Rigidity <strong>and</strong> hence reduction in noise transmission, also as a result <strong>of</strong> the heavierconstruction.. Accessibility for cleaning.Several <strong>of</strong> these claimed advantages may have been valid half a century ago when thetechniques <strong>of</strong> sheet metal duct construction were less well developed <strong>and</strong> when time lag inresponse to automatic control was <strong>of</strong> less significance. They must now be questioned <strong>and</strong>considered in the light <strong>of</strong> the proven difficulty <strong>of</strong> producing any form <strong>of</strong> builders' workconstruction which is reasonably air-tight.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!