Air-water systems 393tested by manufacturers <strong>and</strong> individual tests may be required. Outside temperaturecompensation <strong>of</strong> the heating circuit is an energy efficient way <strong>of</strong> minimising this effect.Fan-coil systems are inherently flexible <strong>and</strong> are well suited to refurbishment projectssince any central air h<strong>and</strong>ling plant <strong>and</strong> duct distribution system will be relatively small insize. The cabinet type <strong>of</strong> unit, as Figure 14.19, has been designed specifically for applicationto existing buildings, the component parts being stacked vertically in a small plan area,space being available there also to enclose vertical water piping <strong>and</strong> a supply air duct.Air±water induction systemsAlthough there has been virtually no development in the design <strong>of</strong> this type <strong>of</strong> unit forsome years, it is appropriate, nevertheless, to outline the principles <strong>of</strong> their operation <strong>and</strong>application. As the name implies, the principle <strong>of</strong> induction is employed in this system as ameans to provide for an adequate air circulation within a conditioned room. Primary air,conditioned in a central plant, is supplied under pressure to terminal units, generallyplaced below the window with vertical discharge, each <strong>of</strong> which incorporates a series <strong>of</strong>jets or nozzles as shown in Figure 14.20. The air induced from the room flows over thecooling or heating coils <strong>and</strong> the mixture <strong>of</strong> primary <strong>and</strong> induced air is delivered from agrille in the sill. The induction ratio is from three to one to six to one. The primary airsupply provides the quantity for ventilation purposes, <strong>and</strong> the means to humidify inwinter <strong>and</strong> deal with latent loads in summer.The coils are fed with circulating water which, in the so-called change-over system,is cooled in summer <strong>and</strong> warmed in winter, an arrangement more suited to sharplydefined seasons than the unpredictable long springs <strong>and</strong> autumns <strong>of</strong> the British climate.In Figure 14.21 (a) <strong>and</strong> (b), control is achieved by an arrangement <strong>of</strong> dampers, such thatPrimaryair supplyWatercirculationFlexible ductconnectionPiping tounit coilControlLint screenCoilInductionjetsStructuralinfillRecirculationgrilleFigure 14.20 Air-water induction unit (two pipe)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!