11.07.2015 Views

Book - School of Science and Technology

Book - School of Science and Technology

Book - School of Science and Technology

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Traditional systems 3770.50.60.70.80.91.00.90.80.70.60.20.30.40.10Sensible/total heatratio for wateradded at 30°C0.75–10 –5 0 5 10 1520 25 30 35 40Specific enthalpy kJ/kg45 50 55 60 650.80Specific volume m /kg0.853258 09 0Percentagesaturation0.5200.10.40.30.20.2 0.1 0.300.61.00.30.1152.11.00.12.90.61.93.7 5.30.2100.85.22.76.50.76.41.156.62.50.25.71.96.40.85.20.10 4.7 5.5 1.3 0.43.6 3.6 1.0 0.1–5 1.6 2.7–10 0.20.60.3 1.3 0.10.3Wet-bulb temperature °C (sling)7 06 05 04 03 02 01 00.0200.0180.0160.0140.0120.0100.0080.0060.0040.002Moisture content kg/kg (dry air)65605550450.000–10 –5 0 5 10 15 20 25 30 35Dry-bulb temperature °C–10 –5 0 5 10 1520 25 30 35 40Specific enthalpy kJ/kgFigure 14.2 Annual percentage frequencies <strong>of</strong> coincident dry-bulb <strong>and</strong> wet-bulb temperatures for theLondon areasatisfactorily through the range <strong>of</strong> annual external conditions. To this end it is necessaryto have an underst<strong>and</strong>ing <strong>of</strong> the range <strong>and</strong> frequency <strong>of</strong> occurrence <strong>of</strong> coincident wet-bulb<strong>and</strong> dry-bulb external conditions. Figure 14.2 shows, on a psychrometric chart, theannual percentage occurrence <strong>of</strong> external conditions lying within specified limits. yTraditional systemsCentral plantThe basic elements <strong>of</strong> air-conditioning systems <strong>of</strong> whatever form are:Fans for moving air.Filters for cleaning air, either fresh or recirculated, or both.Cooling plant connected to heat exchange surface, such as finned coils for cooling <strong>and</strong>dehumidifying air.Heater batteries for warming the air, such as hot water or steam heated coils or electricalresistance elements.Humidifiers, such as by steam injection, water sprays/washers or heated pan type.A control system to regulate automatically the amount <strong>of</strong> cooling, warming, humidificationor dehumidification.y Holmes, M. J. <strong>and</strong> Adams, F. S., Coincidence <strong>of</strong> Dry <strong>and</strong> Wet Bulb Temperatures. BSRIA Technical NoteTN2/77.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!