11.07.2015 Views

Book - School of Science and Technology

Book - School of Science and Technology

Book - School of Science and Technology

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

334 Combustion <strong>and</strong> chimneysMaterials for chimneys <strong>and</strong> flues (gas fired boilers)For each unit <strong>of</strong> heat released, combustion <strong>of</strong> natural gas will produce between one <strong>and</strong> ahalf <strong>and</strong> two <strong>and</strong> a half times as much water vapour as will combustion <strong>of</strong> oil or coal.Hence, condensation is likely to occur in gas flues <strong>and</strong> chimneys, particularly on start-up.Masonry constructed chimneys should be lined with an impervious <strong>and</strong> acid-resistingmaterial such as glazed stoneware or refactory lining. It is desirable to keep the chimneywarm to assist draught, either by enclosing it in brickwork or concrete, or by insulation.Connecting flues between such boilers <strong>and</strong> vertical chimneys are usually <strong>of</strong> double-wallstainless steel.Special methods for flue gas disposal (Natural gas)Apart from the conventional chimneys mentioned, a number <strong>of</strong> special methods for fluegas disposal have been developed, principally by the various research bodies within thegas industry. Some <strong>of</strong> these have been adapted for use with equipment burning thelightest grades <strong>of</strong> fuel oil but such applications apply only on a domestic scale.Reference should be made to BS 5440 Part 1 1990 that describes the requirements,locations, clearances, etc., applicable to the installation <strong>of</strong> such flues for gas appliancesup to 60 kW.Fan diluted draughtIn this system, one form <strong>of</strong> which is shown in Figure 12.13, the combustion products,together with a quantity <strong>of</strong> diluting air, are exhausted to the atmosphere by a fan. By thismeans it is possible to dispense with a chimney entirely, for a gas fired boiler plant, bydischarging through the wall <strong>of</strong> the boilerhouse. The diluting air quantity must be such asDiluting airinletBoiler room ventilatorFan failure deviceOutletCombustionair inletFanBoilers with built-indraught divertersCombustionair inletFigure 12.13 Fan diluted draught

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!