AR300 CONTROL PANEL LAYOUT14762 351. Tank Pressure Gauge – used to monitor the R-134a Recovery TankPressure2. Low Side Pressure Gauge and Valve – with Valve closed, measureAuto A/C low side pressure.3. High Side Pressure Gauge and Valve – with Valve closed, used tomeasure Auto A/C high side pressure.4. Purge Switch Power Switch – used to purge NCG’s from R-134aRecovery Tank5. Main Power Switch6. LCD Display – used to instruct and inform the user of the AR300operation7. Key Pad – used to program the operation of the AR300a. MODE Key – input key to start mode selection right afterRefrigerant Selection.b. lb/kg Key – input key to select units of weightmeasurement.c. STOP Key – used as an input key during operation. Canalso be used to abort the operation of the unit while runningin modes 1 through 8. Can also be used to abort during theprogramming sequence.d. + ARROW Key – used as an input key to scroll throughoperational modes. Also used as input key to increaseprogram times and charge weights. Also used to selectrefrigerant mode and other programming selections.e. - ARROW Key – same as + ARROW Key, except reversescroll and decreases program time and charge weight.f. SET Key – used as an input key to select operational mode.Also used as an input key during programming.6
AR300 REAR LAYOUT1615181 56748129111013141. Hose Holders2. Scale or Load Cell3. Recovery Tank4. Fan5. IEC Electrical Connection6. Circuit Breaker7. High Pressure Reset8. Sight glass9. Oil Injector10. Liquid Hose11. Vapor Hose12. Purge Hose13. Vacuum Pump Hose14. Vacuum Pump15. Vacuum Pump Receptacle16. Filter Shell17. Oil Drain Bottle18. Printer Connection17327
- Page 1 and 2: ®REFRIGERANT RECOVERY/RECYCLE/EVAC
- Page 3 and 4: INTRODUCTIONThank you for purchasin
- Page 5: INITIAL EQUIPMENT PREPARATION1. Car
- Page 9 and 10: AR300 OPERATION MODESSTART UPTurn M
- Page 11 and 12: AR300 OPERATION MODESWhen the Vacuu
- Page 13 and 14: AR300 OPERATION MODESWhen the AR300
- Page 15 and 16: AR300 OPERATION MODESPush the “ST
- Page 17 and 18: AR300 OPERATION MODES7 FLUSHINGXX:X
- Page 19 and 20: ROUTINE MAINTENANCEMODE 9B. FILTER
- Page 21 and 22: OTHER ROUTINE MAINTENANCE ISSUESVAC
- Page 24: WARRANTY & REPAIR POLICYCPS guarant
AR300 REAR LAYOUT1615181 56748129111013141. Hose Holders2. Scale or Load Cell3. Recovery Tank4. Fan5. IEC Electrical Connection6. Circuit Breaker7. High Pressure Reset8. Sight glass9. Oil Injector10. Liquid Hose11. Vapor Hose12. Purge Hose13. Vacuum Pump Hose14. Vacuum Pump15. Vacuum Pump Receptacle16. Filter Shell17. Oil Drain Bottle18. Printer Connection17327