Running DiagnosticsFigure 44. A/D DiagnosticsCount, Voltage, Error Count, Start and Stop - To start the test, click Start. The Count andVoltage boxes display the A/D count and voltage. If the A/D count varies outside the rangedetermined by the A/D Threshold Deviation value, an error is recorded in the Error Count box.To stop the test, click Stop.12.2 <strong>Load</strong> Bank Diagnostic<strong>Load</strong> bank diagnostics may be used in two ways. Click a single step On to display the loadcurrent, battery voltage, and step resistance; or perform a cumulative resistance test, whichsaves the individual step resistance to the setup file.If the user do not enable Auto Detect Step Resistance (refer to <strong>Load</strong> Bank), the user must enterthe resistance for each step. There are two methods to obtain this information, and acombination of the two may be necessary. After resistance values are entered, the data issaved with the load bank setup information for the currently selected load bank.4200-020R2.0 38 9/25/2009