BELÜFTUNGSTECHNIK<br />
UMWELT- & VERFAHRENSTECHNIK<br />
SERVICE & WARTUNG<br />
G E N E R A L I N F O R M A T I O N<br />
OXYFLEX<br />
®<br />
- MF <strong>1100</strong><br />
MEMBRANE-PLATE-DIFFUSER<br />
For fine bubble aeration of liquids<br />
Supratec<br />
von-Drais-Straße 7<br />
D-55469 Simmern/Hunsrück<br />
Fon: *49 (0 67 61) 9 65 09-00<br />
Fax: *49 (0 67 61) 9 65 09-01<br />
e-mail: info@<strong>supratec</strong>.<strong>cc</strong> internet: www.<strong>supratec</strong>.<strong>cc</strong><br />
GESELLSCHAFT FÜR U MWELT-<br />
U N D VERFAHRENSTECHNIK mbH
Supratec<br />
®<br />
OXYFLEX -MF<br />
General<br />
Information<br />
Design<br />
Membrane<br />
Characteristics<br />
Gesellschaft für Umweltund<br />
Verfahrenstechnik mbH<br />
Supratec Gesellschaft für Umwelt- und Verfahrenstechnik mbH produces modern<br />
high efficient aeration systems, which are mainly used for oxygen transfer into<br />
biological waste water treatment. These products can also be used for any kind of<br />
transfer of gases into liquids<br />
OXYFLEX ® is the brand of <strong>membrane</strong> <strong>diffuser</strong>s (<strong>plate</strong>, tubes and discs) with a<br />
plastic body.<br />
The extra ordinary characteristics of OXYFLEX ® - MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s<br />
are given by its shape and the materials used.<br />
OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s are available in two sizes:<br />
• OXYFLEX ® -MF 650 (width x length) 650 mm x 150 mm and<br />
• OXYFLEX ®<br />
-MF <strong>1100</strong> (width x length) <strong>1100</strong> mm x 200 mm.<br />
The body is a oval <strong>plate</strong>, made of glass reinforced made of Polypropylene. The<br />
<strong>membrane</strong> is fixed to this body with a plastic frame also made of glass reinforced<br />
Polypropylene.<br />
Standard <strong>membrane</strong>s are made of EPDM.<br />
Membranes made of Silicone and Polyurethane are also available.<br />
The <strong>membrane</strong>s have a unique slot-arrangement. The size and arrangement of<br />
those slots is optimized to achieve maximum oxygen transfer efficiency.<br />
OXYFLEX ® - MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s have low pressure loss.<br />
OXYFLEX ® - MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s are highly resistant against soiling.<br />
OXYFLEX ® - MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s produce fine bubbles of a medium<br />
diameter < 2 mm.<br />
Unlike tube <strong>diffuser</strong>s, the whole active <strong>diffuser</strong> surface is at the same hydraulic<br />
level, therefore the <strong>membrane</strong>s operate evenly across the full range from minimal<br />
to maximal air flow. This feature results in optimum lifetime and efficiency.<br />
OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s can be operated intermittently.<br />
OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s can be installed with plastic- and/or<br />
stainless steel pipes and are used for all geometric forms of tanks, but they are<br />
extraordinarily good for medium and huge sized tanks.<br />
OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s are well established and are working to<br />
the clients satisfaction world-wide.<br />
Performance OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s have a very wide range 2-25 Nm³/h.<br />
Combination<br />
Variations<br />
The design air flow should be approximately 12 ± 2Nm³/h.<br />
OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s can reach specific oxygen transfer<br />
efficiency up to 25 gO2/Nm³xmsub, if coverage and water depth is favourable.<br />
For plants with partly intermittent operated tanks, OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong><br />
<strong>diffuser</strong>s can be combined with BRANDOL ® ceramic tube <strong>diffuser</strong>s. However,<br />
different pressure losses have to be considered<br />
Modified OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s are also available for drinking<br />
water purposes.<br />
OXYFLEX ® -MF <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s are also available as coarse bubble<br />
<strong>diffuser</strong>s<br />
von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (0 67 61) 9 65 09-00 • Fax: +49 (0 67 61) 9 65 09-01 • info@<strong>supratec</strong>.<strong>cc</strong>
Supratec<br />
Gesellschaft für Umweltund<br />
Verfahrenstechnik mbH<br />
®<br />
D R A W I N G OXYFLEX MF<strong>1100</strong> ‘B’<br />
Membrane Plate Diffuser<br />
®<br />
OXYFLEX -MF <strong>1100</strong> Type ‘B’ will be installed to a<br />
rectangular pipe by 4 welded thread bolts, those are<br />
welded to the pipe.<br />
Materials:<br />
Body: Polypropylen (PP-GF)<br />
Frame: Polypropylen (PP-GF)<br />
Gasket: EPDM<br />
Membrane: EPDM<br />
Polyurethan<br />
Silicon<br />
Membrane area: 0,2 m²<br />
Frame 2 pieces<br />
Frame 2 pieces<br />
Distributor Pipe<br />
Distributor Pipe<br />
30<br />
1105<br />
Frame<br />
Distributor<br />
Membrane<br />
Body <strong>plate</strong><br />
Threat-bolt M6 x 35mm<br />
Hole in Pipe Ø 30mm<br />
Membrane<br />
Gasket<br />
Air-socket<br />
Hole Ø 30mm<br />
von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (0 67 61) 9 65 09-00 • Fax: +49 (0 67 61) 9 65 09-01 • info@<strong>supratec</strong>.<strong>cc</strong><br />
227<br />
30<br />
270
Frame<br />
2 pieces<br />
Frame<br />
2 pieces<br />
Membrane<br />
Clamp<br />
Thread connection<br />
Hole Ø 25mm<br />
Distributor in different diameter<br />
e.g. DN 100, DN 80<br />
Stainless steel or plastic<br />
Supratec<br />
Gesellschaft für Umweltund<br />
Verfahrenstechnik mbH<br />
®<br />
D R A W I N G O X Y F L E X - M F 1 1 0 0 ‘ A S ’<br />
Membrane Plate Diffuser<br />
®<br />
OXYFLEX -MF <strong>1100</strong> Type ‘AS’ will be mounted onto<br />
distributor with a welded clamp (different diameter<br />
available).<br />
Materials:<br />
Body: Polypropylen (PP-GF)<br />
Frame: Polypropylen (PP-GF)<br />
Clamp:<br />
Polypropylen (PP)<br />
Gasket: EPDM<br />
Membrane: Polyurethane<br />
EPDM<br />
Membrane area: 0,2 m²<br />
Frame<br />
Body<br />
Distributor Pipe<br />
1105<br />
Membrane<br />
Clamp<br />
Thread Connection 2”<br />
Gasket<br />
Hole Ø 25mm<br />
von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (0 67 61) 9 65 09-00 • Fax: +49 (0 67 61) 9 65 09-01 • info@<strong>supratec</strong>.<strong>cc</strong><br />
20 30<br />
65<br />
227<br />
270
OXYFLEX<br />
®<br />
- MF <strong>1100</strong><br />
MEMBRANE-PLATE-DIFFUSER<br />
For fine bubble aeration of liquids<br />
- No guarantee-claims can be derived from the diagram!<br />
specific O2-entrainment standard conditions and pressure loss<br />
®<br />
OXYFLEX -MF <strong>1100</strong><br />
Supratec<br />
von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (0 67 61) 9 65 09-00 • Fax: +49 (0 67 61) 9 65 09-01 • info@<strong>supratec</strong>.<strong>cc</strong><br />
Gesellschaft für Umweltund<br />
Verfahrenstechnik mbH<br />
C U R V E S P r e s s u r e - O x y g e n<br />
®<br />
OXYFLEX -MF <strong>1100</strong> <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong> are high efficient <strong>diffuser</strong>s, and are mainly used for oxygen supply<br />
to bioligical waste water treatment plants.<br />
Beside procedural necessities, important criterions are used to select the matching fine-bubble aerationtechnology<br />
to the features of a treatment plant.<br />
®<br />
Systems using OXYFLEX -MF<strong>1100</strong> <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong>s are typically designed at a specific air-flow of 12<br />
Nm³/h per unit.<br />
This gives a good compromise between capital investment and efficiency.<br />
The following table shows figures taken from an actual oxygen efficiency test.<br />
The values have been reached in a carrousel basin with water depth of 5,0m, submergence of <strong>diffuser</strong>s of 4,8m<br />
and coverage of 16,2% (in the aeration zones - 2 zones per tank).<br />
These are typical values particular to the test basin. The figures can deviation ± 25% in tanks of different sizes and<br />
<strong>diffuser</strong> density and loading.<br />
SUPRATEC would be pleased to produce a data-sheet for any individual application on request.<br />
OCL,h [gO 2/(Nm³<br />
x m ET)]<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
0<br />
�p<br />
OC<br />
2 4 6 8 10 12 14 16<br />
specific load [Nm³/h]<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
�p [mbar]
Supratec<br />
Gesellschaft für Umweltund<br />
Verfahrenstechnik mbH<br />
I N S T A L L A T I O N M A N U A L<br />
OXYFLEX ® OXYFLEX - MF <strong>1100</strong><br />
-B-<br />
MEMBRANE MEMBRANE-PLATE-DIFFUSER<br />
PLATE DIFFUSER<br />
FOR For fine FINEbubble BUBBLE aeration AERATION of liquids OF LIQUIDS<br />
Description<br />
Measurements<br />
Storage<br />
Preparation<br />
Levelling<br />
Installation<br />
®<br />
OXYFLEX ® -MF <strong>1100</strong> – <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong> Type ’AS’ has a solid,<br />
strong, horizontal body, made of glass-reinforced Polypropylene and a<br />
slipped over <strong>membrane</strong> (e.g.: EPDM).<br />
The two-piece-frame, made of glass-reinforced Polypropylene ensures<br />
the proper location of the <strong>membrane</strong>.<br />
The body has an air-socket of ∅29 mm.<br />
This clamp can be fastened by screws or wedges.<br />
The integral gasket of the clamp seals the system.<br />
Width: .. 215mm, Length: .. 1105mm, Height: ..30mm<br />
- with rounded edges.<br />
Free <strong>membrane</strong> area: Length: <strong>1100</strong> mm, Width: 210 mm (0,2 m²)<br />
The <strong>diffuser</strong>s should be stored in their packing inside a dry and aerated<br />
building. DIN 7716 has to be considered.<br />
Before installation of the OXYFLEX ® - MF <strong>1100</strong> - <strong>membrane</strong> <strong>plate</strong><br />
<strong>diffuser</strong> Type -B- it has to be checked that the piping system is clean.<br />
Drilling chips, dirt etc. have to be removed, as those will be transported<br />
into the <strong>diffuser</strong>s as soon as blowers are set into operation causing<br />
serious damage to the <strong>diffuser</strong> <strong>membrane</strong>s.<br />
OXYFLEX ® -MF <strong>1100</strong> - <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong> Type -B- are normally<br />
installed onto rectangular pipes. The piping system has to be levelled to<br />
maximum ± 10 mm.<br />
OXYFLEX ® -MF <strong>1100</strong> - <strong>membrane</strong> <strong>plate</strong> <strong>diffuser</strong> Type -B- can be fixed<br />
to rectangular pipes made of stainless steel. On the upper side of those<br />
pipes, centred holes of diameter ∅ 30 mm must be made and 4 threatbolts<br />
are welded onto this pipe.<br />
The <strong>diffuser</strong>'s air socket must fit in the a.m. hole. The bolts will suit into<br />
the 4 holes in the two-piece-frame of OXYFLEX ® -MF <strong>1100</strong> - <strong>membrane</strong><br />
<strong>plate</strong> <strong>diffuser</strong> Type -B-.<br />
Care must be taken of the horizontal seat of the <strong>diffuser</strong>s. The gasket,<br />
made of EPDM must be clean and undamaged and should sit between<br />
<strong>diffuser</strong> and pipe.<br />
von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (0 67 61) 9 65 09-00 • Fax: +49 (0 67 61) 9 65 09-01 • info@<strong>supratec</strong>.<strong>cc</strong>
f o r f i n e b u b b l e a e r a t i o n o f l i q u i d s<br />
MEMBRANE-PLATE-DIFFUSER<br />
For fine bubble aeration of liquids<br />
Function<br />
and<br />
Leakage Check<br />
First Run of<br />
Diffusers<br />
Visual Bubble<br />
Check<br />
Oxygen-<br />
Transfer-<br />
Efficiency Test<br />
Start up<br />
Supratec<br />
Gesellschaft für Umweltund<br />
Verfahrenstechnik mbH<br />
O P E R A T I O N M A N U A L<br />
®<br />
OXYFLEX - MF <strong>1100</strong><br />
®<br />
After installation of OXYFLEX -MF <strong>1100</strong> Membrane Plate Diffusers a function and leakage test<br />
should be carried out.<br />
The tank should be filled with clean water up to maximum 10 cm above <strong>diffuser</strong>s’ surface and the<br />
<strong>diffuser</strong>s set in operation.<br />
Then function and installation can be checked and confirmed by report.<br />
®<br />
After function and installation has been checked and confirmed OXYFLEX -MF <strong>1100</strong> Membrane<br />
Plate Diffusers have to be operated at least another 60 hours continuously.<br />
Water level shall be as quickly as possible raised up to minimum 100 cm above <strong>diffuser</strong>s’ surface.<br />
IMPORTANT: • Diffusers should not stand still<br />
The visual judgement of the bubble distribution should not be taken before the above specific first run<br />
of <strong>diffuser</strong>s.<br />
To do the visual check, the <strong>diffuser</strong>s shall operate at maximum capacity and shall be turned to the<br />
minimum.<br />
• Test of even aeration (visual bubble check) must take place when the water level is at least 60-100<br />
cm above <strong>diffuser</strong>s’ surface.<br />
• Test of even aeration (visual bubble check) at minimum air flow can only take place if the water<br />
temperature is above 10°C.<br />
®<br />
Before the stated oxygen transfer efficiency figures of the OXYFLEX -MF <strong>1100</strong> Membrane Plate<br />
Diffusers are proved with an oxygen transfer efficiency test, the above mentioned steps have to be<br />
considered.<br />
The oxygen transfer efficiency test must be done a<strong>cc</strong>ordingly to a<strong>cc</strong>epted rules (e.g. ATV-M 209) in<br />
clean or waste water.<br />
Guarantee figures have to be controlled exactly. It is necessary to have a precise air-flow<br />
measurement system.<br />
®<br />
After su<strong>cc</strong>essful oxygen transfer efficiency test, start up of the OXYFLEX -MF <strong>1100</strong> Membrane Plate<br />
Diffusers may follow immediately. If there is a postponement of the start up, care should be taken that<br />
®<br />
the water level stays at least 100 cm above <strong>diffuser</strong>s’ surface to protect OXYFLEX -MF <strong>1100</strong><br />
Membrane Plate Diffusers from sunlight and / or freezing.<br />
von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (0 67 61) 9 65 09-00 • Fax: +49 (0 67 61) 9 65 09-01 • info@<strong>supratec</strong>.<strong>cc</strong>
Supratec<br />
Gesellschaft für Umweltund<br />
Verfahrenstechnik mbH<br />
M A I N T E N A N C E M A N U A L<br />
OXYFLEX<br />
®<br />
- MF <strong>1100</strong><br />
MEMBRANE-PLATE-DIFFUSER<br />
For fine bubble aeration of liquids<br />
Maintenance<br />
Supervision<br />
Warranty<br />
®<br />
OXYFLEX -MF <strong>1100</strong> Membrane Plate Diffusers do not need a lot of maintenance. Usually it is<br />
enough to have one run of 10 to 15 minutes operation at maximum air-flow per day.<br />
To do so, it may help to shut down the system partially, by closing the corresponding valves.<br />
This removes layers of sludge which may have o<strong>cc</strong>urred after long times of in operation of the system<br />
or long times of low specific air flow.<br />
®<br />
At least once per year OXYFLEX -MF <strong>1100</strong> Membrane Plate Diffuser should be checked visually,<br />
particulary they should be checked for layers of sludge or similar. If so, those layers should be<br />
removed carefully.<br />
A seperate maintenance-contract is available.<br />
A Visual bubble check should be carried out daily. The pressure loss of the system should be<br />
monitored and reported monthly.<br />
Apparent changes of the bubble distribution and/or of the pressure loss should be promptly reported<br />
®<br />
to SUPRATEC GmbH, especially at installations with intermittent operation where there is a risk that<br />
®<br />
activated sludge could penetrate the entire piping through a damaged OXYFLEX -MF <strong>1100</strong><br />
®<br />
Membrane Plate Diffuser which would affect function and lifetime of all OXYFLEX -MF <strong>1100</strong><br />
Membrane Plate Diffusers in the system.<br />
®<br />
®<br />
The maximum of SUPRATEC GmbH’s warranty for OXYFLEX -MF <strong>1100</strong> <strong>membrane</strong> is 24 months.<br />
Longer warranty can be arranged only with conclusion of a maintenance contract between the<br />
®<br />
operator and SUPRATEC GmbH.<br />
Damage and/or other influences are specifically excluded from the warranty promise.<br />
®<br />
The maximum of SUPRATEC GmbH's warranty for Membrane-Plate-Diffuser OXYFLEX MF is 24<br />
month.<br />
Longer warranty can be arranged only with conclusion of a maintenance contract between the<br />
operating and SUPRATEC GmbH.<br />
Damages and/or outer influences are specifically excluded from the warranty promise.<br />
The warranty ends if it known, that sewage is partially mainly full of industrial origin and/or the<br />
sewage has damaging influence on <strong>membrane</strong> <strong>diffuser</strong>s and the SUPRATEC GmbH was not<br />
informed a<strong>cc</strong>ordingly. In such case, a confirmation of the warranty is to be ordered through the<br />
SUPRATEC GmbH.<br />
The correction of vaults in the warranty is to determine by approval. In case of warranty starts a 2<br />
year long warranty for the changed <strong>diffuser</strong>s. Is the first warranty longer running, it apply till it ends.<br />
The general sales and warranty conditions of SUPRATEC GmbH are valid, and can be appreciate at<br />
www.<strong>supratec</strong>.<strong>cc</strong>.<br />
von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (0 67 61) 9 65 09-00 • Fax: +49 (0 67 61) 9 65 09-01 • info@<strong>supratec</strong>.<strong>cc</strong>