11.07.2015 Views

SCP-2K4 series - Meanwell

SCP-2K4 series - Meanwell

SCP-2K4 series - Meanwell

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

..File Name:<strong>SCP</strong>-<strong>2K4</strong>-SPEC 2007-03-012400W Parallel (N+1) With PFC Function<strong>SCP</strong>-<strong>2K4</strong> <strong>series</strong>SPECIFICATIONORDER NO.<strong>SCP</strong>-<strong>2K4</strong>-09 <strong>SCP</strong>-<strong>2K4</strong>-12 <strong>SCP</strong>-<strong>2K4</strong>-15 <strong>SCP</strong>-<strong>2K4</strong>-18 <strong>SCP</strong>-<strong>2K4</strong>-24 <strong>SCP</strong>-<strong>2K4</strong>-36 <strong>SCP</strong>-<strong>2K4</strong>-48SAFETY MODEL NO.DC VOLTAGERATED CURRENTCURRENT RANGERATED POWER<strong>2K4</strong>S-P0099V266A0~266A2394W<strong>2K4</strong>S-P01212V200A0~200A2400W<strong>2K4</strong>S-P01515V160A0~160A2400W<strong>2K4</strong>S-P01818V133.3A0 ~ 133.3A2399W<strong>2K4</strong>S-P02424V100A0~100A2400W<strong>2K4</strong>S-P03636V66.6A0 ~ 66.6A2397W<strong>2K4</strong>S-P04848V50A0~50A2400WOUTPUT RIPPLE & NOISE (max.) Note.2 90mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-pVOLTAGE ADJ. RANGE ± 3.0% Typical adjustment by potentiometer 20% ~ 100% adjustment by 1~5VDCexternal controlVOLTAGE TOLERANCE Note.3LINE REGULATIONLOAD REGULATION± 2.0%± 0.5%± 1.5%± 1.0%± 0.5%± 0.5%± 1.0%± 0.5%± 0.5%± 1.0%± 0.5%± 0.5%± 1.0%± 0.5%± 0.5%± 1.0%± 0.5%± 0.5%± 1.0%± 0.5%± 0.5%SETUP, RISE, HOLD UP TIME 800ms, 400ms, 12ms at full loadVOLTAGE RANGEFREQUENCY RANGEPOWER FACTOR180 ~ 260VAC47~63Hz>0.98 / 230VAC3ψ3 wire (other system available)INPUT EFFICIENCY (Typ.)83% 84% 85%86%88%88%89%AC CURRENT15A / 230VACINRUSH CURRENT (max.) 60A / 230VACLEAKAGE CURRENT(max.) 3.5mA / 240VACOVERLOAD Note. 4110 ~ 140% rated output powerProtection type : Current limiting, delay shut down o/p voltage, re-power on to recoverPROTECTION OVER VOLTAGE110 ~ 135% Follow to output set up pointProtection type : Shut down o/p voltage, re-power on to recoverOVER TEMPERATURE>100 ℃ / measure by heat sink, near transformerProtection type : Shut down o/p voltage, recovers automatically after temperature goes downWORKING TEMP.WORKING HUMIDITYENVIRONMENT STORAGE TEMP., HUMIDITYTEMP. COEFFICIENTVIBRATIONSAFETY &EMC(Note. 5)OTHERSNOTESAFETY STANDARDS UL60950, TUV EN60950-1 ApprovedWITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVACISOLATION RESISTANCE I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC / 25 ℃ / 70% RHEMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) class AHARMONIC CURRENT Compliance to EN61000-3-2,3EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria ADIMENSIONPACKING-20 ~ +65 ℃ (Refer to output load derating curve)20 ~ 90% RH non-condensing-20~+85 ℃ ,10~95%RH± 0.04% / ℃ (0 ~ 50 ℃ )10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axesPOWER GOOD SIGNALSPECIAL FUNCTIONOpen collector of NPN transistorDC Voltage Adj., Remote sensing, remote control, parallel operation(refer to control terminal instruction manual)COOLING By fan, >20% load or >50℃fan onMTBF 24.9K hrs min. MIL-HDBK-217F(25 ℃ )350*212*124mm (L*W*H)9.0kg ; 1pcs / 10kg / CARTON■ ψψψ<strong>SCP</strong>-<strong>2K4</strong>-60<strong>2K4</strong>S-P06060V40A0~40A2400W200mVp-p℃± 1.0%± 0.5%± 0.5%89%


File Name:<strong>SCP</strong>-<strong>2K4</strong>-SPEC 2007-03-012400W Parallel (N+1) With PFC Function<strong>SCP</strong>-<strong>2K4</strong> <strong>series</strong>Mechanical SpecificationUnit:mm123.9 [4.88] 212[8.35]Air flowdirection332 [13.07]6-M6 SCREWFOR DC OUTPUTLED8-M3X0.5 Terminal BlockFor Control Signal1 2 3 4 5 6 7 8 V-ADJ15-M4X0.7 Terminal blockFor AC Input2 3 4 5POS(+)NEG(-)6 [0.24] TYP320 [12.60] 30 [1.18]180[7.09]4-M4X0.7 MOUNTINGHOLE FOR USER290 [11.42] 24 [0.94]Control Terminal Pin. No. Assignment :Pin No.1234AssignmentVS+VS-VCIVCOPin No.5678AssignmentPGPARGNDINHAC Input Terminal Pin. No. AssignmentPinNo. Assignment PinNo. Assignment1 FG4 S2 N5 R3 TDerating CurveTa=25℃LOAD (%)10080604020OUTPUT POWER (W)240020001200900-20 -10 10 20 30 40 50 60 70AMBIENT TEMPERATURE ( ℃ )90 110 150 170 260INPUT VOLTAGE (VAC) 60Hz


2400W Parallel (N+1) With PFC Function<strong>SCP</strong>-<strong>2K4</strong> <strong>series</strong>Control terminal instruction manualLOADLOADLOADLOADVS+VS-VCIVCOPGPARGNDINHVS+VS-VCIVCOPGPARGNDINHVS+VS-VCIVCOPGPARGNDINHON/OFF SWITCHVS+VS-VCIVCOPGPARGNDINHH:ONL:OFFUSING INTERNAL VOLTAGE CONTROLREMOTE SENSINGON/OFF CONTROL BY SWITCHON/OFF CONTROL BY TRANSISTORGOODFAIL: LED OFF:LEDON120VoutO.V.P. 120% (Typ.)100VS+VS-VCIVCOPGPARGNDINHLOAD40V / 0.5A MAX.VS+VS-VCIVCOPGPARGNDINHLOADDC 1-5VOUTPUT VOLTAGE (%)80604020Non-LinearPOWER GOOD SIGNALOUTPUT VOLTAGE ADJUST WITH DC 1-5V1 2 3 4 5 6EXTERNAL VOLTAGE (DC)VLOADLOADVS+VS-VCIVCOPGPARGNDINHVS+VS-VCIVCOPGPARGNDINHVS+VS-VCIVCOPGPARGNDINHVS+VS-VCIVCOPGPARGNDINHVS+VS-VCIVCOPGPARGNDINHVS+VS-VCIVCOPGPARGNDINHPARALLEL OPERATION WITH REMOTE SENSINGPARALLEL OPERATION WITHOUT REMOTE SENSINGFile Name:<strong>SCP</strong>-<strong>2K4</strong>-SPEC 2007-03-01


2400W Parallel (N+1) With PFC Function<strong>SCP</strong>-<strong>2K4</strong> <strong>series</strong>FIG. A: 3 3W 220VAC SYSTEM (STANDARD MODEL FOR STOCK)R220V 220VSTRL1FG1N1SL2N2 FG2TL3N3 FG3N (NC)FGFIG. B: 1220VAC SYSTEM220VLNRSTNL1FG1N1L2N2 FG2L3N3 FG3FGFIG. C: 34W 220/380VAC SYSTEM220VRNRSTNL1FG1N1L2N2 FG2L3N3 FG3SFG380VTFIG. D: 34W 190/110VAC SYSTEMR110VNS(N.C.)RL1FG1N1SL2N2 FG2TL3N3 FG3N (NC)190VTFGFile Name: <strong>SCP</strong>-<strong>2K4</strong>-SPEC 2007-03-01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!