10.07.2015 Views

Environmental Impacts of Multi-Storey Buildings Using Different ...

Environmental Impacts of Multi-Storey Buildings Using Different ...

Environmental Impacts of Multi-Storey Buildings Using Different ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

- 43 -Table 5.1: Simulation inputs valuesData Value Unit SourceMetabolic Rate 0.9 Met Ashrae comfort toolOccupancy 0.1 People/m 2 NZS:4243Plug Load (Office Equipment) 8 W/m 2 NZS:4243Heating set point 22 Celsius E CubeNatural ventilation 24 Celsius E CubeCooling set point 26 Celsius E CubeMin. fresh air 8 l/s - person NZS:1330Lifts 4 kWh/m 2 NZGBCInfiltration 0.25 ACH* NZGBCDHW 4 kWh/m 2 NZGBCLighting 400 Lux AS/NZS 1680.1:2006Lighting power density 13.6 W/m 2 DesignBuilderDuring the design process, changes to improve performance were mostly related to variation<strong>of</strong> thermal mass and the improvement <strong>of</strong> the thermal envelope and for example by addinginsulation to the ro<strong>of</strong> slab.5.2.2 Floor Areas for SimulationThe analysis <strong>of</strong> the results <strong>of</strong> this research used the net usable area. The ventilation systemoccupies a large area <strong>of</strong> space within the building; the large vertical void areas used aschimneys connected to a plant room on the ro<strong>of</strong> were taken out <strong>of</strong> the gross floor area for thecalculation <strong>of</strong> the net usable area.Table 5.2 shows the initial gross floor area (calculated inside the envelope walls), thensegregated in floor area allocated to the ventilation chimneys and plant room, <strong>of</strong>fices andcorridors floor area. Finally, Table 5.2 shows the net usable area which was calculated addingthe <strong>of</strong>fice floor area plus corridors floor area.Table 5.2: Calculation <strong>of</strong> the Net Usable Area for the analysis <strong>of</strong> resultsGross floor area 4,247 m 2Chimneys and plant room 711 m 2Offices 2,745 m 2Corridors 792 m 2Net usable area (Offices + Corridors): 3,536 m 2Initially, the net usable area was used for the calculation <strong>of</strong> the operating energy consumptionintensity per square metre. Subsequently, in order to have a single result for life-cycle energyconsumption per square metre, the initial and recurrent embodied energy were subdividedalso for net usable area. All results with reference to the intensity <strong>of</strong> energy per square meterare presented in net usable area.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!