Contactors and Contactor AssembliesContactors for Switching MotorsSIRIUS3RT10 contactors, 3-poleI Selection and ordering dataAC operation» «« «3RT103.-1A.OORatingsUtilization categoryAC-3Maximum Maximum "inductive horsepowercurrent ratings at 460VAC-1Maximumresistivecurrent3RT103.-3A.OO: AuxiliarycontactsIdent.no.DesignRated controlsupply voltageU,3RT104.-1A.OO. ... .,Screw connectionOrder No.3RT104.-3A.OOCage Clamp connectionfor coil terminalsOrder No.^Weightapprox.A HPNO NC ACFor screwina and snapping onto 35 mm standard mounting rail ^g^^^^gg^^^^^^g^^^^^g^^^^^^|• Size S228 2032 2540 3050 40• Size S365 5080 6095 7535 - - - 24 V, 50/60 Hz120V, 60 Hz240 V, 60 Hz50 - 24 V, 50/60 Hz120V, 60 Hz240 V, 60 Hz60 - - 24V, 50/60 Hz120V, 60 Hz240 V, 60 Hz55 - - - 24 V, 50/60 Hz120V 60 Hz240 V, 60 Hz100 - - - 24V 50/60 Hz120V 60 Hz240 V 60 Hz120 - - - 24V, 50/60 Hz120V, 60 Hz240 V, 60 Hz120 - - - 24V, 50/60 Hz120V 60 Hz240 V, 60 Hz3RT1033-1AC203RT1033-1AK603RT1033-1AP603RT10 34-1 AC203RT1034-1AK603RT1034-1AP603RT1035-1AC203RT1035-1AK603RT1035-1AP603RT1036-1AC203RT1036-1AK603RT1036-1AP603RT1044-1AC203RT1044-1AK603RT1044-1AP603RT1045-1AC203RT1045-1AK603RT1045-1AP603RT1046-1AC203RT1046-1AK603RT1046-1AP603RT10 33-3AC203RT10 33-3AK603RT10 33-3AP603RT10 34-3AC203RT10 34-3AK603RT10 34-3AP603RT10 35-3AC203RT10 35-3AK603RT10 35-3AP603RT10 36-3AC203RT10 36-3AK603RT10 36-3AP603RT10 44-3AC203RT10 44-3AK603RT10 44-3AP603RT1045-3AC203RT1045-3AK603RT1045-3AP603RT10 46-3AC203RT10 46-3AK603RT10 46-3AP60kg0.780.780.780.781.781.781.78For fur<strong>the</strong>r voltages, see page 3/32.For accessories, see page 3/36-47.For spare parts, see page 3/54-58.For technical data, see page 3/80, 3/91-98.For description, see page 3/12-13.For int. circuit diagrams, see page 3/135.For dimension drawings, see page 3/170-172.3/181) Complete horsepower ratings onpage 3/80.Discount Code: SIRIUS Contactors, OL's, MSP'sSiemens Energy & Automation, Inc.Industrial Controls <strong>Catalog</strong>


Contactors andContactors for Switching MotorsSIRIUS3RT10 contactors 1 ' ' 1• Technical dataContactorSizeTypesoo3RT1015SOO3RT10 16SOO3RT10 17SOSO3RT10 23/24 3RT10 25SO3RT10 261 @ and ® ratings of <strong>the</strong> contactors ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^1Rated insulation voltageACV 600600Continuous current, at 40 "CMaximum horsepower ratings(@ and ©-approved values)Ratingsof three-phase motorsat 50/60 HzShort-circuit protection(contactor or overload relay)NEMA/EEMAC ratingsConventional <strong>the</strong>rmal currentRatingsof three-phase motorsat 60 HzOverload relayFree air and enclosedRatingssinglephase motorsat 50/60 Hzat 115Vat 230 V200V230V460V575VFuse or circuit-breakerace. to UL 489NEMA/EEMAC SIZEFree airEnclosedat 200 V230V460V575VTypeSetting rangeAHPHPHPHPHPHPkAAAAAHPHPHPHPA201/43«1 1 /223556050-3RU11 160.11 ... 121/312357 1 /2560501/22337 1 /21056050018183355351/3 1/21 22/3 53/3 55/7 1 / 2 107 1 /2/10 155 570 7070 70-3RU11 21.8... 25137 1 /27 1 /215205100100127277'/27'/21010ContactorSizeTypeS233/3RT1034S23RT1035S23RT1036S33RT1044S33RT1045S33RT1046Rated insulation voltageACV600600Continuous current, at 40 CFree air and enclosedA45555090 105Maximum horsepower ratings(§ and Si-approved values)Ratingsof three-phase motorsat 50/60 HzRatingssinglephase motorsat 50/60 Hzat 115Vat 230 Vat 200 V230V460V575VHPHPHPHPHPHP257 1 / 2/101020/2525/3037%10153040310151540505 Tk15 1520 2525 3050 6060 7510303075100Short-circuit protectionFuse or circuit-breakerace. to UL 489kAAA51251255150150520020010 10250 300250 30010350400NEMA/EEMAC ratingsConventional <strong>the</strong>rmal currentRatingsof three-phase motorsat 60 HzNEMA/EEMAC SIZEFree airEnclosedat 200 V230V460V575VAAHPHPHPhp-2454510152525-3909025305050Overload relayTypeSetting rangeA3RU11 35.5 ... 503RU11 418 ... 100ContactorSOOScrew connection andCage Clamp connectionIntegrated orsnap-onauxiliary switch blockSO... S12Screw connection andCage Clamp connectionSingle-pole and 4-polesnap-onauxiliary switch blockScrew connection andCage Clamp connectionLaterallymountableauxiliary switch block@ and ® ratings of <strong>the</strong> auxilarv contactsRated voltageMaking and breaking capacityConventional <strong>the</strong>rmalcurrent at AC 240 V^^^^^^^^^^^^^^^^^^^^^^^^^^^AC/DC 600600600A (AC)A (DC)A 600, Q 600102.5A 600, Q 600102.5A 300, Q 300102.53/80 Siemens Energy & Automation, Inc.Industrial Controls <strong>Catalog</strong>


SIRIUSContactors and ContactorContactors for Switching Motors3RT10 3. contactorsI Technical dataContactorGeneral dataSizeTypePermissible mounting positionThe contactors are designed tor operationon a vertical mounting surface.323RT1034S23RT1035S23RT1036AC and DC operation 360° 22,5° 22,5° For DC operation and forward/». e inclination up to 22.5°:/I | coil voltage tolerance 0.85 ... 1.1 x U sUpright mounting position:MechanicalenduranceAC operationDC operationBasic units Oper. 10 millionBasic unit with snap-on auxiliary switch block cycles 10 millionSolid-state compatible aux. switch block5 million<strong>Electrical</strong> endurance See page 3/79Rated insulation voltage (/ (pollution degree 3) 690Rated impulse withstand voltage U in, vSafe isolation between coil and main contacts(ace. to DIN VDE 0106 Part 101 and A1 [draft 2/89])Positively driven operationThere is positively driven operation if <strong>the</strong> NC andNO contacts cannot be closed at <strong>the</strong> same timekV3RT103., 3RT133.(removable aux. switch block)Special design required.Positions 13 to 16 of <strong>the</strong> Order No. must be changed to -1AAO.Additional charge.400Yes, between main contacts and auxiliary NC contacts and within<strong>the</strong> auxiliary switch blocks ace. to ZH 1/457, IEC 60 947-4-1,Annex H (draft 17B/996/DC)3RT103., 3RT133. in accordance with Swiss regulations (SUVA) on request.(permanent aux. switch block)Permissible ambient temperature in operation °C -25 ... +60when stored °C -55 ... +80Degree of protection ace. to IEC 60 947-1 and DIN 40 050 IP 20 (terminal compartment IP 00), coil system IP 40Shock resistanceRectangular pulse AC and DC operationSine pulse AC and DC operationg/msg/ms10/5 and 5/1015/5 and 8/10Conductor cross-sections See page 3/94Short-circuit protection of contactors without overload relaysMain circuitFuse links, utilization category gl_/gGNH Type SNA, DIAZED Type 5SB, NEOZED Type 5SE- ace. to IEC 60 947-4-1/EN 60 947-4-1 Type of coord. "V 1 )Type of coord. "2- 1 )Weld-free 2 )Auxiliary circuitFuse links, utilization category gl_/gG A 10DIAZED Type 5SB, NEOZED Type 5SE (weld-free protection at /„ > 1 kA)or miniature circuit-breaker with C-characteristic (short-circuit current 7 k < 400 A) A 10For short-circuit protection of contactors with overload relays, see1 Part 4.For short-circuit protection of weld-free contactors, see Part 5.(overload and short-circuit protection only with 3RV10 circuitbreaker).For short-circuit protection of fuseless load feeders, see Part 5.125631616080501) According to excerpt fromIEC 60 947-4-1 (VDE 0660 Part 102):Type of coordination "1":Destruction of <strong>the</strong> contactor and <strong>the</strong> overloadrelayis permissible. The contactor and/or overloadrelay must be replaced if necessary.Siemens Energy & Automation, Inc.Industrial Controls <strong>Catalog</strong>Type of coordination "2":No damage can be tolerated to <strong>the</strong> overload relay,but contact welding on <strong>the</strong> contactor is permitted if<strong>the</strong> contacts can be easily separated.2) Test conditions ace. to IEC 60 947-4-1.For 3RT11 weld-free contactors, see Part 5(overload and short-circuit protection only with3RV10 circuit-breaker).3/91

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!