10.07.2015 Views

Systematic review, meta-analysis and economic modelling of ...

Systematic review, meta-analysis and economic modelling of ...

Systematic review, meta-analysis and economic modelling of ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Assessment <strong>of</strong> diagnostic <strong>and</strong> prognostic accuracyTABLE 10 Index <strong>and</strong> reference st<strong>and</strong>ard tests used in studies <strong>of</strong> H-FABPStudy Index test analyser Threshold (µg/l) Reference test assay <strong>and</strong> timingReference Tn diagnosticthreshold (µg/l)MI prevalence insample (%)Body 2011 57 Alere Fluorescence immunoassay 58 Roche Elecsys TnT at least 12 hours aftersymptom onset0.01 18Cete 2010 58 CardioDetect ® 6.2 TnT; assay not reported; 6 hours 0.1 33Charpentier CardioDetect ® 7 ADVIA Centaur TnI system (Bayer Diagnostics) at2010 59 6 hours0.1 15Di Serio 2005 63 R<strong>and</strong>ox Evidence Investigator 6.4 ESC/ACC, not further specified Not specified 53Ecollan 2007 64 CardioDetect ® 7 Dade Behring TnI over 24 hours 0.07 (99th percentile) 51Garcia-Valdecasas Dainippon Pharmaceutical ELISA 6.2 Dade Dimension TnI; timing not stated 0.6 392011 49Haltern 2010 67 HyCult Biotechnology ELISA 7 Roche Elecsys TnT at 12 hours 0.03 33Hjortshoj 2010 68 HyCult Biotechnology ELISA 6.0 Roche Elecsys TnT at 6–9 hours, <strong>and</strong>12–24 hours0.03 33Ilva 2009 50 Innotrac Aio! Immunoanalyzer 10.4 Abbott Architect TnI up to 24 hours 0.032 46Lefebvre 2007 72 CardioDetect ® 6.2 Dade Behring RxL TnI or Siemens Centaur TnI 0.14 <strong>and</strong> 0.33 48Li 2010 73 Wuhan EasyDiagnosis Biomedicine Co 7 TnT; assay not specified; 12 hours 0.1 50Liao 2009 74 CardioDetect ® 7 NR; NR; assumed to be 10–12 hours 0.5 73Mad 2007 75 CardioDetect ® 7 TnT; no details <strong>of</strong> assay; ACC <strong>and</strong> ESC guidelines(10–12 hours)0.04 39McCann 2008 76 HyCult Biotechnology ELISA 1.2 Roche Elecsys TnT at 12 hours 0.03 48Mion 2007 77 Evidence ® Cardiac Panel 6.02 Dimension RxL TnI; timing NR (as ESC/ACCguidelines)0.15 32Naroo 2009 78 CardioDetect ® 7 Assay not specified; 6–12 hours after initialsampling1 13Valle 2008 82 CardioDetect ® 7 TnT at 6–12 hours, assay not reported Not stated 35ACC, American College <strong>of</strong> Cardiology; ESC, European Society <strong>of</strong> Cardiology; NR, not reported.38NIHR Journals Library

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!