10.07.2015 Views

Systematic review, meta-analysis and economic modelling of ...

Systematic review, meta-analysis and economic modelling of ...

Systematic review, meta-analysis and economic modelling of ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Assessment <strong>of</strong> diagnostic <strong>and</strong> prognostic accuracyResults <strong>of</strong> the <strong>review</strong>sThis section presents the results <strong>of</strong> the following systematic <strong>review</strong>s separately:1. the diagnostic accuracy <strong>of</strong> biomarkers measured at presentation, including troponin, compared withthe universal definition <strong>of</strong> MI, <strong>and</strong> the prognostic accuracy <strong>of</strong> biomarkers, excluding troponin, forpredicting MACEs, in unselected patients presenting with chest pain <strong>and</strong> suspected ACS (see Studiesincluded in the biochemical markers <strong>review</strong>, below)2. the diagnostic accuracy <strong>and</strong> prognostic performance <strong>of</strong> exercise ECG <strong>and</strong> CTCA compared withICA for identifying CAD or predicting MACEs in unselected patients presenting with chest pain <strong>and</strong>suspected ACS (see Studies included in the computed tomographic coronary angiography <strong>and</strong> exerciseelectrocardiography <strong>review</strong>, below).Studies included in the biochemical markers <strong>review</strong>Overall, the literature searches identified 2865 citations. A flow chart describing the process <strong>of</strong> identifyingrelevant literature can be found in Figure 2. Of the titles <strong>and</strong> abstracts screened, 182 relevant fullpapers were retrieved <strong>and</strong> assessed in detail. Studies excluded from the <strong>review</strong>, with reasons, are listedin Appendix 3. A total <strong>of</strong> 88 papers evaluating the diagnostic accuracy or prognostic performance <strong>of</strong>biochemical markers met the inclusion criteria. Of these, we were unable to extract appropriate data fromseven studies 36–42 <strong>and</strong> identified three 43–45 in which there seemed to be duplication <strong>of</strong> data with otherincluded studies. A total <strong>of</strong> 40 studies reported data on diagnostic accuracy <strong>and</strong> 44 studies reported dataon prognostic performance, with six <strong>of</strong> these studies reporting both prognostic <strong>and</strong> diagnostic data. 46–51Overview <strong>of</strong> biomarker studies included in the diagnostic <strong>review</strong>Table 2 lists all the studies included in the diagnostic accuracy <strong>review</strong> <strong>and</strong> the biomarkers that wereevaluated with extractable data. We were not able to extract data for all the biomarkers reported in eachstudy. Table 2 lists only the biomarkers with extractable data.Description <strong>of</strong> diagnostic studies <strong>of</strong> presentation troponinWe identified 21 diagnostic studies 19,20,48–50,52–57,59,62–64,66,70,72,74,77,81 <strong>of</strong> presentation TnI <strong>and</strong> 11studies 19,46,58,60,62,67,71,73,76,78,82 <strong>of</strong> TnT for inclusion in the <strong>review</strong>. Two studies 19,62 evaluated TnI <strong>and</strong> T. Thecharacteristics <strong>of</strong> the study populations are outlined in Tables 3 <strong>and</strong> 4, whereas details <strong>of</strong> the index <strong>and</strong>reference st<strong>and</strong>ard test definitions are provided in Tables 5 <strong>and</strong> 6. Some studies evaluated more than oneassay, so assays are reported separately in Tables 3 <strong>and</strong> 4. Reporting <strong>of</strong> inclusion <strong>and</strong> exclusion criteria werevariable <strong>and</strong> several studies excluded patients with a diagnostic ECG. Prevalence <strong>of</strong> MI varied from 5% to73% <strong>and</strong> was relatively high, suggesting that patient cohorts may have been subject to implicit selectionprocesses. Time delay from symptoms to presentation varied from 1.2 hours (mean) to 6 hours (median).Several studies reported data using different diagnostic thresholds for the index test. Where this was donewe extracted data for threshold based on the 99th percentile, 10% coefficient <strong>of</strong> variation (CV) <strong>and</strong> limit<strong>of</strong> detection (LoD). In accordance with our inclusion criteria, all studies used the universal definition <strong>of</strong> MIas the reference st<strong>and</strong>ard, <strong>and</strong> most reported using some form <strong>of</strong> adjudication, taking into account theresults <strong>of</strong> troponin testing. In most cases the troponin used for the reference st<strong>and</strong>ard was a st<strong>and</strong>ard(i.e. not high sensitivity) assay using the 10% CV or 99th percentile as a diagnostic threshold. However,the study by Christ et al. 60 reported the use <strong>of</strong> a reference st<strong>and</strong>ard based on high-sensitivity TnT (HsTnT)alongside a reference st<strong>and</strong>ard based on the st<strong>and</strong>ard assay. For this study we extracted data based on thest<strong>and</strong>ard assay reference st<strong>and</strong>ard.Quality assessments <strong>of</strong> diagnostic studies <strong>of</strong> presentation troponinFigures 3 <strong>and</strong> 4 show the quality assessments for studies <strong>of</strong> TnI <strong>and</strong> TnT, respectively, whereas Figures 5<strong>and</strong> 6 show the methodological quality summaries. The studies were generally high quality, perhapsreflecting exclusion <strong>of</strong> lower-quality studies by our selection criteria. Presentation troponin measurementis obviously not independent <strong>of</strong> a troponin-based reference st<strong>and</strong>ard, so our assessment <strong>of</strong> verification16NIHR Journals Library

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!